Jointers Blogs
132kV Cable Sheath Testing With Pfisterer GIS Terminations
June 17th, 2021
Image Courtesy of: Dan Chessher at Energi Cable Services
Energi Cable Services provides specialist bespoke solutions for the high voltage power cable systems of transmission and distribution electricity network operators. Both on land and subsea, these include: oil filled cable systems, fluid filled cable systems and gas filled cable systems.
pfisterer
The range of Pfisterer cable plugs, joints, terminations fittings and accessories offers solutions for virtually all MV & HV Cable Connection applications – Pfisterer accessories use silicone as an insulating medium due to the excellent properties that it possesses.
There are many advantages of using the Pfisterer MV-Connex cable termination system.
These include:
- A touch proof, fully insulated enclosure
- No liquid insulating medium
- Soil proof and maintenance free cable termination
- Protection class IP68 and up to 11kV (E Exe Hazardous Areas)
- Thorough transformer and GIS (Gas Insulated Switchgear) testing by manufacturer
- Metal enclosed and no need to open the cable termination at the installation site

Jointers blog
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.
Pfisterer Ixosil EST 170 Terminations & Connex 6S Plugs
June 16th, 2021Images Courtesy of: Andy O’Malley EHV Cable Jointer/Splicer



Jointers blog
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.
138kV HPFF Cable Preparation Prior To Installation Of G&W Cable Termination
June 16th, 2021
Image Courtesy of: Terry Perona (Retired) Manager Underground Cable at FirstEnergy
Contractor W.A. Chester prepares 138KV HPFF cable to receive new G&W termination.

Jointers blog
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.
Testing 11kV Whipp & Bourne CV Switchgear Using Megger & Fluke Test Instruments
June 15th, 2021
Pictured : Testing 11kV Whipp & Bourne CV Switchgear Using Megger & Fluke Test Instruments
Image: Liam Medderman – Power Delivery Substation Tester (HV Authorised Person) at Transport for London.

The Whipp and Bourne 11kV CV switchgear, 3 phase type was subjected to a 6 yearly service examination and medium voltage test – the purpose of the test was to prove that the bottles which are located in the lower part of the switchgear would pass 1kV and 5kV Megger tests, (lowest reading permissible being 100M Ohms) using a Fluke tester.

Bottles can be tested by going from front side, to earth, also, at either end of the bottle to prove there is no leakage. All 3 phases passed the test with >3T Ohms and returned to immediate service.

Jointers blog
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.
CT, DC Supply & Voltage Reference Section Between 2 X 2500A Air Circuit Breakers
June 15th, 2021
Image Courtesy of: Neil Probert – Voltage Management & Switchgear Specialist

Jointers blog
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.