Centriforce Tapetile and Stokbord underground cable protection tiles and covers are the market leading, heavy duty utility protection system for protecting underground cable and pipes – this includes low voltage, medium voltage and high voltage power networks working at 11kV/33kV up to and including 132kV/275kV extra high voltage cables.
➡ The following Selection Table outlines the current approved Cable Protection Systems for UK DNO’s for underground medium and high voltage cables.
Northern Powergrid
Centriforce
Tapetile
150×2.5mmx40m
Northern Powergrid
Centriforce
Tapetile
200×2.5mmx40m
Northern Powergrid
Centriforce
Stokbord
1000x244x12mm
Scottish Power
Centriforce
Tapetile
200×2.5mmx40m
Scottish Power
Centriforce
Stokbord
1000x244x12mm
UK Power Networks
Centriforce
Tapetile
200×2.5mmx40m
UK Power Networks
Centriforce
Stokbord
1000x244x9mm
Western Power Distribution (WPD)
Centriforce
Stokbord
1000x450x12mm
Western Power Distribution (WPD)
Centriforce
Stokbord
1000x244x12mm
Scottish & Southern Energy (SSE)
Centriforce
Stokbord
1000x244x12mm
GTC
Centriforce
Tapetile
150×2.5mmx40m
GTC
Centriforce
Tapetile
200×2.5mmx40m
National Grid
Centriforce
Tapetile
200×2.5mmx40m
National Grid
Centriforce
Stokbord
1000x300x14mm
National Grid
Centriforce
Stokbord
1000x450x14mm
Centriforce Benefits
Centriforce Stokbord and Tapetile heavy duty plastic underground cable covers have virtually replaced concrete cable covers, tiles and plates for several reasons:
Clearest warning of underground buried cables to third parties
Can be custom made with sizes to suit specific utility cable protection for 11kV, 33kV, 66kV and 132kV
Contains bold warning text and UK DNO logo for clear cable identification
Damage to medium and high voltage cables less likely therefore reducing the cost of repairs, jointing and outages
Lightweight and easy to install cable covers irrespective of weather and soil conditions
Durable with good impact resistance
Rotproof and resistant cable covers to wide range of soil conditions
Electrical Explosion – An 11kV Cable Strike
Two construction companies have been fined £90,000 after workers were seriously burned, and one scarred for life, after they cut into a live 11kV electrical cable. Unprotected underground cables distributing medium and high voltage electricity pose serious health and safety dangers.
UK DNO’s
T&D are Specialist Distributors to the UK Distribution Network Operators (DNO’s), NERS Registered Service Providers, ICP’s and High Voltage Jointing Contractors of an extensive range of Cable Joints, Substation, Distribution, Tooling & Installation Equipment approved by the utilities:
T&D distribute the most extensive range of LV, MV & HV Cable Jointing, Terminating, Cable Pulling & Installation Equipment – we service UK and international clients working on underground cables, overhead lines, substations and electrical construction at LV, 11kV, 33kV and EHV transmission and distribution voltages.
Thorne & Derrick invite you to join LinkedIn’s largest LV-HV Electrical Discussion Group : Low & High Voltage Power, Cabling, Jointing & Electricals. Discussion subjects include cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV. Network, engage and promote your profile, company or products with over 10,000 influencers.
Request a Quote Call Us: +44 (0)191 410 4292 Stokbord cable protection covers are rigid HDPE protection boards designed to be installed above buried cables in trenches. They are manufactured and designed by Centriforce to provide strong mechanical protection...
Restoring transformer termination integrity with LoviSil When a major site recently experienced a fault on an 11kV transformer termination, the challenge was clear: restore the system quickly, safely and without the expense/disruption of full PILC cable replacement. Upon investigation,...