Straight Cable Joints MV for 11kV 33kV Cables


Lovink Straight Through Cable Joint for MV Cables 11kV 33kV
Lovink LoviSil Medium Voltage Straight Joint
Straight Through MV Cable Joint for XLPE EPR and PILC PICAS
MV Straight Through Cable Joint 11kV 33kV
Lovink Enertech Logo

Lovink LoviSil® Straight Through Cable Joint | MV 6/10 (12) kV – 18/30 (36) kV

Lovink Enertech Logo

Product Code: LoviSil® Straight Joint (Module Selection Required)

12kV Straight Through Cable Joints Available
24kV Straight Through Cable Joints Available
36kV Straight Through Cable Joints Available

Lovink LoviSil® Straight Cable Joint is designed for medium voltage (MV) cable-to-cable connections on polymeric cables (XLPE/EPR) or paper-insulated cables (PILC/PICAS) from 6/10 (12) kV up to 18/30 (36) kV. The LoviSil® straight joint platform supports multiple MV cable constructions including 1-core and 3-core, a wide range of armour types, and conductor sizes up to 1,000 mm² (subject to module selection and cable dimensions). For MV systems commonly referenced as 11kV and 33kV class, the correct straight cable joint configuration is confirmed by the cable ratings, screens/sheaths and physical build.

SEE TECHNICAL SPECIFICATIONS



MV Joints for Straight Cable Connections XLPE – PILC

The Lovink LoviSil® Straight Cable Joint is built for reliable inline cable connections on medium voltage circuits where the cable type is consistent across the joint (polymeric-to-polymeric or paper-to-paper). This makes it a practical option for planned MV
cable jointing work, renewals, repairs and re-terminations where conductor sizes, screens and armours vary across projects.

Lovink LoviSil

Lovink LoviSil® straight joints are suitable for a broad set of MV cable designs including 1-core, 3-core and 3 × 1-core configurations, plus a range of armour constructions and cross-sections. Where cable builds are uncommon, bespoke cable modules may be available to
support the correct fit and electrical performance.

6/10 (12) kV – 18/30 (36) kV Cables

Designed for MV networks up to 36 kV, LoviSil® straight cable joints cover cable system ratings from 6/10 (12) kV to 18/30 (36) kV. For distribution systems commonly referred to as 11kV and 33kV class, selection is completed using the correct cable ratings and dimensions to match module size, screens/sheaths and installation requirements.

 

Need the right Straight Cable Joint for your MV cables? Share your cable data (voltage class, insulation type, conductor size, screen/sheath, armour and key diameters) and we’ll support the correct module selection for your 11kV / 33kV class project.
Thorne & Derrick International provide technical advice, quotations and fast worldwide delivery for medium voltage joints and cable accessories.

Contact Our Experts


Straight Through Cable Joint – Technical Specifications

Lovink LoviSil® Straight Joint (MV) – Key Data

Product Type Straight Cable Joint (Medium Voltage)
Voltage Range 6/10 (12) kV – 18/30 (36) kV
Cable Types (Straight Joint) Polymeric (XLPE / EPR) to Polymeric (XLPE / EPR) OR Paper-Insulated (PILC / PICAS) to Paper-Insulated
Core Types 1-core, 3-core and 3 × 1-core configurations (selection dependent)
Conductor Sizes Up to 1,000 mm² (dependent on module and cable dimensions)
Typical MV Networks MV (including 11kV / 33kV class applications, subject to correct selection)
  • Module selection depends on cable construction, insulation type (XLPE/EPR or PILC/PICAS), sheath/armour and key diameters.
  • For uncommon cable designs, bespoke cable modules may be available on request.
  • Where the cable configuration is 3-core to 3-core, an extended shell variant may be used (selection dependent).

Application Range (Straight Joint Modules)

Module Cable Type Conductor Size (mm²) Crossed Cores (mm)
M85 Polymeric / Paper (1-core) 95 – 500 mm² 82
M105 Polymeric / Paper (1-core) 630 – 1,000 mm² 105
MK125 Polymeric / Paper (1-core) 95 – 400 mm² 56
Polymeric / Paper (3-core) 95 – 500 mm² 120
  • Ranges shown are a selection guide; final suitability depends on cable outer diameters and the selected cable module.
  • For 3-core on 3-core straight jointing, an extended shell option may be used where required (selection dependent).
  • If you have a 3-core on 3 × 1-core requirement, confirm the cable build and dimensions so the correct straight joint solution can be specified.

Straight Joint Dimensions (Module Reference)

Module A (mm) B (mm)
M85 1128 237
M105 1386 289
MK125 1600 310
MK125 (Extended) 1850 310

Dimensions are provided as a quick reference for planning and clearances. Confirm the selected module and the cable build before finalising site requirements.

Construction & Installation Notes (Straight Jointing)

Protection Concept Outer shells + polyurethane resin + LoviSil® insulation for protection against moisture and polluted soil
Build-Up Uniform build-up with pre-installed parts to support efficient on-site assembly
Tools & Method Standard tools stated; no shrinking or soldering required within the system concept
Modular System Base module + cable module + resin module supports project flexibility and reduces stock complexity
Selection Required Confirm insulation type, screen/sheath, armour, conductor size and key diameters before supply

For straight joint selection, share cable schedules/photos where possible. This helps confirm the correct MV straight-through joint module and build for your cable system.


Straight Through Cable Joint – Key Benefits

✔ Purpose-built Straight Through Cable Joint solution for MV cable-to-cable connections (same-cable type)

✔ Suitable for polymeric (XLPE/EPR) or paper-insulated (PILC/PICAS) cables across multiple designs

✔ Supports 1-core, 3-core and 3 × 1-core jointing requirements (selection dependent)

✔ MV voltage range up to 36 kV (6/10 (12) kV to 18/30 (36) kV)

✔ Outer shells + polyurethane resin + LoviSil® construction supports strong moisture and ground contamination resistance

✔ Pre-installed parts and uniform build-up support repeatable installation quality

✔ No shrinking or soldering stated; standard tools only within the jointing concept

✔ Modular platform reduces stock burden across varying cable sizes and armours

✔ Reliable electrical insulation approach aligned with future-ready MV network requirements

✔ Options may include extended shell and alternative straight joint configurations (project dependent)

Straight Cable Joint for MV 11kV 33kV Cables

Applications

✔ Inline MV cable-to-cable connections on polymeric (XLPE/EPR) or paper-insulated (PILC/PICAS) circuits

✔ Planned MV cable jointing, repairs and renewals (same-cable type straight jointing)

✔ Utility distribution and private MV networks (incl. 11kV / 33kV class projects subject to selection)

✔ Substations, RMU feeds, switchrooms and industrial MV distribution

✔ MV circuits with varied armour constructions where a flexible modular joint range supports multiple builds

✔ Projects requiring robust joint protection against moisture and polluted soil conditions

✔ Situations where flame-free installation is preferred (petrochemical and mining environments)


Straight Through Cable Joint – Additional Information

LoviSil® MV cable joints use fluid silicone (liquid insulation) as the primary insulation medium. Unlike shrink or push-on approaches,
the silicone remains liquid, enabling it to flow into and fill potential voids within the joint. This supports stable electrical insulation and
helps minimise partial discharges associated with air entrapment. In contact with water or humid air, an insulating rubber is formed, and
under fault conditions the system is stated to produce no carbon traces.

For 36 kV class jointing, LoviSil® joints can include geometric field control via filled stress cones. Combined with a silicone sleeve
around the connection, this delivers controlled field distribution without the need for wrapping, supporting a compact MV joint design.

Fluid Silicone Liquid Insulation - MV Straight Through Cable Joint

Liquid Insulation (Void-Filling)

Fluid silicone provides primary insulation and is designed to search out and fill voids, supporting consistent insulation across joint components
and reducing the likelihood of partial discharge due to air entrapment.

Field Control Without Wrapping - 36kV Straight Jointing

Field Control (36kV Class)

36 kV class joints can use geometric field control via filled stress cones plus a silicone sleeve, delivering controlled field distribution
without wrapping and supporting a compact joint build.

LoviSil Installation and Reliability

Installation & Reliability

LoviSil® jointing is designed around a logical installation sequence with identifiable components and a transparent inner joint to aid visual control and filling indication.
The platform is stated to have long field experience and low failure rate, supporting strong total cost of ownership (TCO) outcomes.

Reliable insulation environment: fluid silicone supports primary insulation and fills voids to reduce electrical stress points

Polymeric & paper suitability: the silicone-based system is stated as suitable for both polymeric and paper-insulated MV cables

Logistical benefits: modular system helps reduce stock holding required across many MV cable designs

Easy installation: intuitive sequence, pre-mounted parts, and visual control / filling indication

Flame-free approach: no soldering or shrinking stated, supporting petrochemical and mining requirements where flame-free installation is often preferred