Feed-In Cable Joints MV | 11kV 33kV Cables





Lovink LoviSil® Feed-In Cable Joint | MV 6/10 (12) kV – 18/30 (36) kV

Product Code: LoviSil® Feed-In Cable Joint (Module Selection Required)



Lovink LoviSil® Feed-In Cable Joint is purpose-designed for medium voltage (MV) network integration, enabling the direct connection of renewable or distributed power sources into existing underground cable systems without the need for additional switchgear or substations. Suitable for systems rated from 6/10 (12) kV up to 18/30 (36) kV, LoviSil® feed-in joints are widely specified for networks commonly referred to as 11kV and 33kV class.
Designed to accommodate connections between incoming generation cables and established MV distribution circuits, the joint supports polymeric (XLPE/EPR) and paper-insulated (PILC/PICAS) cable types, including single-core and selected multi-core configurations. Conductor sizes up to 1,000 mm² can be supported depending on the joint module and application requirements.
MV Feed-In Joints for Polymeric & Paper Cables (XLPE PILC)
The Lovink LoviSil® Feed-In Cable Joint is a specialist medium voltage (MV) jointing solution designed to connect embedded generation and renewable energy sources directly into existing underground distribution networks. Unlike conventional jointing arrangements that require additional switchgear or substation infrastructure, the feed-in joint enables a compact, underground connection point within the cable system itself.
LoviSil® Fluid Silicone Technology
At the core of the design is LoviSil® liquid silicone insulation, which remains fluid within the joint body to fully encapsulate conductors, connectors and stress control components. This void-free insulation method minimises the risk of partial discharge and supports long-term dielectric reliability in demanding underground environments. Combined with a durable outer shell and resin-based mechanical protection, the joint delivers dependable performance in moisture-prone or contaminated soil conditions. Installation is flame-free, requires only standard tooling, and avoids heat shrink or soldered components.
6/10 (12) kV – 18/30 (36) kV Networks
Suitable for 6/10 (12) kV through to 18/30 (36) kV systems, LoviSil® Feed-In Joints are commonly specified for networks referred to as 11kV and 33kV class. The joint accommodates a wide range of polymeric (XLPE/EPR) and paper-insulated (PILC/PICAS) cable types, including large conductor cross-sections up to 1,000 mm² (subject to configuration). This makes the system particularly well suited to wind farms, solar parks, industrial generation facilities and other distributed power schemes requiring reliable grid integration.
Need the right Cable Joints for your MV cables? Speak to our trusted experts to confirm suitability for your 11kV / 33kV class network application (as well as cable type, insulation, sheath/armour construction and dimensions). Thorne & Derrick International provide technical advice, quotations and fast worldwide delivery for MV joints, medium voltage cable accessories and engineered power solutions.
MV FEED-IN Cable Joint – Technical Specifications
Lovink Cable Joints – Selection Guide
FEED-IN Cable Joint – Key Benefits
✔ Advanced feed-in joint solution engineered for secure connection of MV distribution cables to network systems
✔ Suitable for modern polymeric insulated cables and selected legacy cable interfaces in MV installations
✔ Rated for medium voltage applications up to 36 kV depending on system configuration
✔ Enhanced environmental sealing using multi-layer insulation and high-performance sealing compounds
✔ Pre-assembled components help ensure consistent quality and shorten installation time
✔ Installation designed around common professional tools without complex heat-shrinking processes
✔ Modular construction philosophy supports flexible adaptation to different cable designs
✔ Developed in line with the engineering standards for dependable network performance
✔ Provides strong resistance against groundwater ingress and soil contamination effects
✔ Suitable for distribution grids requiring durable, low-maintenance MV jointing solutions

Applications
✔ MV cable network entry and distribution connection points using modern feed-in jointing technology
✔ Linking of underground MV feeders to substations, kiosks and ring main circuits
✔ Compatibility with polymeric insulated medium voltage cables in distribution systems
✔ Suitable for infrastructure expansion, reinforcement and network reconfiguration projects
✔ Use in commercial, municipal and utility-operated MV power delivery systems
✔ Integration into renewable energy, storage and decentralized generation connections
✔ Field installation situations requiring dependable electrical sealing and mechanical stability
✔ Designed in accordance with engineering practices for distribution network reliability
Feed-In Cable Joint – Additional Information
The MV feed-in cable joint system is designed to provide a secure electrical and mechanical interface for underground distribution feeders entering network nodes. The joint construction uses engineered insulation materials combined with sealed structural housing to maintain stable performance under variable load conditions. This solution is particularly suited for distribution circuits where reliability and environmental durability are essential, especially in outdoor or buried network segments.
For medium voltage installations, the feed-in joint design supports controlled electric field management through integrated stress regulation elements and precision-moulded insulation layers. When deployed in modern distribution assets, the system helps maintain stable impedance characteristics and reduces the risk of localised electrical ageing in connected cable sections, following engineering practices.
✔ Supports secure MV feeder entry connections in underground distribution environments
✔ Engineered for polymeric insulated medium voltage cable systems
✔ Helps reduce electrical stress concentration at termination transition zones
✔ Reinforced sealing architecture for improved resistance to groundwater and particulate ingress
✔ Suitable for utility network expansion, reinforcement and asset renewal projects
✔ Designed for professional field installation using standard MV cable preparation tools
✔ Supports stable long-term operation in distribution feeders supplying urban and industrial loads