ABB EXCOUNT-III Surge Counters | Remote & Real Monitoring of High Voltage Power Systems
Published 15 Sep 2022

ABB EXCOUNT-III Surge Counters for MV and HV Power Systems
ABB developed EXCOUNT-III to provide remote, real-time monitoring of surge arresters. The system helps utilities monitor arrester performance and assess electrical stresses within high voltage substations.
As electricity networks become more demanding, online condition monitoring is increasingly important. Therefore, utilities need reliable information to support maintenance decisions and reduce unexpected outages.
The ABB EXCOUNT-III Surge Counters provide detailed information about surge activity and arrester condition. In addition, the recorded data supports insulation co-ordination assessments across the substation.
By combining remote monitoring with diagnostic information, EXCOUNT-III helps operators understand how surge arresters respond to electrical disturbances.
What Are Surge Counters?
Surge counters record electrical surge events affecting surge arresters. These devices help operators monitor surge activity within medium and high voltage power systems.
Surge arresters protect electrical equipment against potentially damaging overvoltages. However, repeated electrical stresses can affect their condition over time.
Consequently, monitoring provides useful information for maintenance planning. Regular visual inspections and diagnostic checks also remain important.
ABB has extensive experience developing surge arresters and associated accessories. Drawing on this expertise, the EXCOUNT range focuses on safety, functionality and long-term reliability.
Furthermore, short-circuit safety is considered within the design of the EXCOUNT surge counter range.

ABB EXCOUNT-III Remote Surge Arrester Monitoring
Electricity network operators aim to maintain a reliable power supply while reducing unplanned interruptions. As a result, condition monitoring has become an important part of substation maintenance.
Surge arresters protect electrical equipment from transient overvoltages. During electrical disturbances, they may experience significant current impulses.
Although these events can be brief, they provide valuable information about stresses affecting the power system.
For this reason, ABB developed EXCOUNT-III to monitor surge activity and support diagnostic analysis.
Real-Time Monitoring and Diagnostic Information
EXCOUNT-III is a remote monitoring, diagnostics and analysis system for surge arresters. Depending on the selected version, it records several important operating parameters.
These include:
- Total surge count: Records the number of discharge events.
- Surge amplitude: Measures the magnitude of surge current impulses.
- Wave steepness: Provides information about the rate of change of the surge current.
- Date and time: Records when surge events occur.
- Total leakage current: Monitors leakage current through the arrester.
- Resistive leakage current: Supports assessment of arrester condition.
In addition, the advanced system can use recorded surge information to estimate the residual voltage across the arrester.
Consequently, operators can assess potential overvoltages affecting nearby equipment. This information also supports more detailed insulation co-ordination studies.
Overall, EXCOUNT-III provides information about both arrester performance and electrical conditions within the substation.

Monitoring Overvoltages Across the Substation
EXCOUNT-III does more than record surge arrester operations. The advanced version can also estimate overvoltages affecting equipment within the arrester’s protection zone.
For example, recorded surge current characteristics can help engineers assess whether the existing protection arrangement is suitable.
Furthermore, the information can support decisions about arrester selection, placement and insulation co-ordination.
As a result, utilities gain a clearer understanding of the electrical stresses experienced by their equipment.
IEC 61850 and SCADA Integration
ABB EXCOUNT-III supports IEC 61850 Edition 2 for communication with compatible substation monitoring systems.
Using an optical fibre connection, the system allows recorded information to be accessed remotely. Therefore, operators can integrate relevant signals into an existing SCADA system.
Remote access also reduces the need for site visits solely to retrieve surge arrester monitoring data.
Importantly, personnel do not need to approach an energised arrester to perform routine online diagnostic readings. This provides an additional safety benefit for substation operators.
EXCOUNT-III Applications and Performance Data
The EXCOUNT-III system uses individual sensors connected through optical fibre communication. Each sensor can be accessed separately for monitoring and data analysis.
In addition, the system can be integrated into compatible SCADA installations. It is designed for use with different makes and types of gapless surge arresters.
Key Features and Benefits
- Remote, real-time monitoring of surge arresters.
- Supports assessment of arrester condition and substation electrical stresses.
- Does not add voltage to the arrester’s residual voltage.
- Reduces substation visits for routine monitoring.
- Supports IEC 61850 Edition 2 communication.
- Allows integration with compatible SCADA systems.
- Enables analysis of surge current impulses.
- Supports more detailed insulation co-ordination assessments.
- Provides a straightforward monitoring interface.
- Designed for maintenance-free operation.
As a result, EXCOUNT-III offers a practical monitoring solution for high voltage substations and electrical power networks.
ABB EXCOUNT Surge Counter Range
ABB offers several EXCOUNT models for surge arrester monitoring. The range includes EXCOUNT-C, EXCOUNT-I, EXCOUNT-II and EXCOUNT-III.
Each model provides different monitoring capabilities. Therefore, selection should reflect the required measurements, communication functions and installation conditions.
| EXCOUNT-C | EXCOUNT-I | EXCOUNT-II | EXCOUNT-III |
![]() |
![]() |
![]() |
![]() |
EXCOUNT-III Design Features
EXCOUNT-III is available in two versions: EXCOUNT-IIIA and EXCOUNT-IIIM.
Both versions provide monitoring capabilities. However, the advanced model offers additional surge analysis functions.
EXCOUNT-IIIA Advanced Monitoring
The advanced EXCOUNT-IIIA version records detailed information about surge arrester operation.
For each connected arrester, it can record:
- Total number of surge discharges.
- Surge current amplitude.
- Surge wave steepness.
- Date and time of occurrence.
- Total leakage current.
- Resistive leakage current.
Furthermore, resistive leakage current is assessed through third-harmonic analysis using Method B2 of IEC 60099-5.
The advanced model also uses high-speed sampling to capture complete surge current impulses. Consequently, engineers can examine the characteristics of individual surge events.
EXCOUNT-IIIM Standard Monitoring
EXCOUNT-IIIM is intended for applications that do not require detailed overvoltage analysis.
Instead of recording complete surge waveforms, the standard version categorises discharges according to their amplitude.
Each event also receives a date and time stamp. Meanwhile, other general monitoring features remain available across the versions.
Optical Fibre Communication
A web browser interface allows users to access individual EXCOUNT-III units through an optical fibre connection.
In addition to viewing monitoring data, users can configure the equipment through this interface.
The system also supports IEC 61850 communication for compatible SCADA integration. Therefore, utilities can include arrester monitoring information within existing data collection arrangements.


EXCOUNT-III ABB Surge Counters
EXCOUNT-III Surge Registration
Surge registration is an important feature of the EXCOUNT-IIIA advanced monitoring system.
In addition to counting discharge events, it records surge amplitude and wave steepness. This information allows engineers to estimate the residual voltage across the arrester during an electrical surge.
Consequently, operators can assess potential overvoltages within the substation more accurately.
For example, this information may indicate whether the existing surge protection arrangement is adequate.
Alternatively, the recorded results may support a review of arrester selection or the number of arresters installed.
Furthermore, engineers can compare surge front times and estimated overvoltages with information from transformer monitoring equipment.
As a result, EXCOUNT-III contributes to wider electrical system condition monitoring and diagnostic analysis.
Leakage Current Measurement and Condition Monitoring
EXCOUNT-III measures both total leakage current and the resistive component of current flowing through the surge arrester.
In particular, resistive leakage current provides useful information about arrester condition.
Changes in this measurement can help operators assess whether an arrester remains suitable for continued service.
Furthermore, monitoring data can be integrated into a compatible SCADA system. This allows maintenance teams to review arrester condition alongside other substation information.
Consequently, maintenance or replacement activities can be planned using recorded condition data.
This approach can help reduce unnecessary interventions and support efforts to prevent unplanned power outages.
EXCOUNT-III Safety and Remote Monitoring
Safety is an important consideration when monitoring energised surge arresters.
EXCOUNT-III allows operators to retrieve monitoring information remotely through an optical fibre connection. Therefore, personnel do not need to approach the arrester simply to obtain routine diagnostic readings.
In addition, remote monitoring can reduce substation visits undertaken solely to assess arrester condition.
Weatherproof Construction and Installation
EXCOUNT-III components are housed within a sealed, weatherproof enclosure suitable for outdoor installation.
The base unit is mounted on the support structure and connected in a similar arrangement to a conventional surge counter.
Meanwhile, a separate field probe is installed at the bottom of the surge arrester.
The system also requires an external power supply and optical fibre communication connection.
Its auxiliary power requirements are:
- Supply voltage: 100–250V AC or DC.
- Communication: Optical fibre connection.
- Installation: Outdoor, weatherproof equipment housing.
As a result, the system combines remote access, diagnostic monitoring and outdoor installation capability.
Thorne & Derrick – MV and HV Electrical Equipment

Thorne & Derrick are specialist distributors of LV, MV and HV cable installation, jointing, substation and electrical equipment.
We supply products for the installation, energisation, operation and maintenance of underground cables and overhead power lines.
Our customers operate across utilities, onshore and offshore wind, solar, rail, oil and gas, data centres and battery energy storage.
In addition, we support contractors and electrical engineers with specialist products for power distribution and electrical infrastructure.
Explore Our Electrical Equipment Range
Thorne & Derrick supply a wide range of electrical installation and maintenance products. Explore the following categories:
- Surge Counters
- Cable Duct Sealing Systems
- Cable Cleats, Clamps and Hangers
- LV, MV and HV Electrical Safety Equipment
- Arc Flash Clothing and PPE
- Cable Jointing and Termination Tools
- Cable Pulling and Laying Equipment
- Electrical Feeder Pillars
- Cold Shrink Cable Joints
- Heat Shrink Cable Accessories
- MV and HV Cable Joints, Terminations and Connectors
For technical information, product selection or availability, contact Thorne & Derrick to discuss your electrical equipment requirements.


HV Joints, Terminations and Connectors | 11kV/33kV up to 66kV Ex Stock