Jointer Training – MV Cable Terminations & Separable Connectors (Module 1)

Published 27 Sep 2018

Nexans

MV & HV Jointer Competency Training Courses

  • uploaded by Chris Dodds - Thorne & Derrick Sales & Marketing Manager

Cable Jointer Training

Requirements, Expectations & Rewards

Thorne & Derrick, the International Distribution Partners of Nexans Power Accessories, have united to provide an industry commitment to ensuring the safe and reliable installation of MV-HV Cable Accessories – a series of 10 Training Modules are available to support the training requirements for Cable Jointers upskilling from LV to MV to HV with tailored courses at 11kV, 33kV and 66kV voltage levels.

The Modules cover MV & HV Cable Terminations, Joints & Separable Connectors.

Get Nexans Competent Not Familiar

These Jointer Training Courses are not introductory “Familiarisation” courses – each prospective candidate will be vetted prior to acceptance onto the course. If suitably qualified and experienced the candidate will be accepted onto the course – they will be required to undertake MV cable preparation and submit a test piece of cable with their cable termination, joint or separable connector installed. The submission will then be tested for AC withstand and partial discharge (PD) in the new “state-of-the-art” Nexans Test Laboratory.

Upon successful completion of the Laboratory Test the candidate will be presented with a 3 Part Certificate of Competency.

MV Cable Terminations & Separable Connectors

Module 1 

The 1 day Training Course will be targeted on product application only – requiring the candidate to install the product Competently. No cable preparation training will be provided. Attendees will be expected to be able to prepare MV cables for a range of Medium Voltage Cable Accessories.

Training Framework Plan
Training Mode Single Core XLPE Polymeric Power Cable
Duration 1 Day 9am-5pm
Attendees Min 2 Max 6
Goals & Learning Objectives Time Frames, Measurability, Observability. Less than 10pC @ 2Uo
Equipment Included Cable, Accessories, PPE, Training Boards & Lunch
Equipment Requirements Cable Prep & Jointing Tools – Steel Toe Cap Boots

Jointer Training Schedule

Training Schedule Course Contents
Introductions Welcome
Health & Safety
Training Acknowledgements – Privacy Policy
PABG
Competency Understanding Equipment
MV Cable Construction & Cable Preparation
Electrical Stress & Stress Control
MV Cable Termination Failures
Practical MV Cable Preparation
Installation
MV Cable Termination Failures
Testing  Equipment Testing In Shielded Room For AC Withstand & Partial Discharge (PD)
Conclude Technical / Product Support
3 Part Jointer Competency Certificate, Including Test Report

 

Book A Training Course

Call Thorne & Derrick to enquire about course costs, dates or to request a booking form.

  • Training Centre Co-Ordinator:  Martin Wigham 0191 4104292

    Training Course 11kV 33kV

    Safeguarding Standards | Supporting Craftmanship | Protecting Reputations

 

The Jointer Training Course is carried out at:Nexans map

NexansTraining Centre
Units 1 & 2 Good Hope Close,
Normanton Industrial Estate, Normanton,
West Yorkshire,
WF6 1TR

 

Nexans Jointer Training

THORNE & DERRICK

T&D are Specialist Distributors to UK Distribution Network Operators (DNO’s), NERS Registered Service Providers, ICP’s and HV Jointing Contractors of an extensive range of LV, MV & HV Cables, Jointing, Earthing, Substation & Electrical Eqpt – this includes 11kV/33kV/66kV cable joints, terminations and separable connectors.

Contact our UK Power Team for competitive quotations, fast delivery from stock and technical support or training on all LV-HV products.

Key Product Categories: Duct Seals | Cable Cleats | Cable Glands | Electrical Safety | Arc Flash Protection | Cable Jointing Tools | Cable Pulling | Earthing | Feeder Pillars | Cable Joints LV | Joints & Terminations MV HV 

Cable Terminations | Heat Shrink | Cold Shrink | Push-On | Separable Connectors | MV HV

 ➡ Read: Thorne & Derrick Announce Distribution Agreement & Contract With Nexans 

Nexans 11kV 33kV 66kV