Nexans H07RN-F Cables | Heavy-Duty Industrial & ATEX Applications
Available at Thorne & Derrick, the Nexans H07RN-FÂ is a robust, heavy-duty rubber cable engineered for power distribution in tough industrial and ATEX environments. Offering high flexibility, oil resistance, and flame-retardant properties, this waterproof cable is ideal for construction sites, generators, portable equipment, and other demanding industrial applications.
This Nexans H07RN-F complies with international standards for safety and performance in environments exposed to mechanical, thermal, and chemical stress. The flexible, rubber cable is recommended for use in dry, damp or wet workshops, typically those of explosive atmospheres, according to the ATEX regulation of the country.
Key Features of Nexans H07RN-F Cable:
-
Flexible rubber insulation for dynamic applications
-
 Oil-resistant and waterproof construction
-
 Flame-retardant to EN/IEC power cable standards
-
Suitable for indoor, outdoor, and ATEX rated zones
-
UV and abrasion resistant for long service life
-
 Voltage rating: 450/750 V
-
Ideal for temporary power, lighting, and heavy-duty tools
Designed by one of the world’s most reputable, reliable and high-quality cabling manufacturers, the Nexans H07RN-F is the ideal solution for installations with moving equipment, electrical appliances, motors in lifting appliances, machinery tools and more. Think this cable will be suitable for your operations? Find out more in the technical specifications and FAQs sections, as well as the cable core selection guide, aiding discovery of specific part number information.
Ready to place an order? Contact our experts – find out more about the Nexans H07RN-F.
Thorne & Derrick International, based in the UK, stock and distribute power products worldwide.
Nexans H07RN-F Technical Specifications
The following table provides a complete insight on the technical specifications for the Nexans H07RN-F cable. Need specific specifications? Keep scrolling to view our extensive selection of heavy-duty flexible rubber cable variants, manufactured by Nexans.
Nexans H07RN-F Cable Technical Specifications | |
---|---|
Conductor Shape | Circular |
Insulation | Cross-linked synthetic elastomer (Type EI4) |
Sheath Colour | Black |
Rated Voltage U0/U (Um) | 450/750 V |
Phase Reactance (50 Hz, Trefoil Formation) | Not specified (contact for details) |
Impact Resistance | Very good |
Flexibility | Flexible |
Waterproof | Good |
Max. Conductor Temperature | 85 °C |
Oil Resistance | Yes |
RoHS Compliant | Yes |
Cable Core Selection Guide
The following tables include the complete variant catalogue for the Nexans H07RN-F cable, which are categorised by number of cable cores. Click on the cable core section you’d like to view to jump to its dedicated table: Single Core, Two Cores, Three Cores, Four Cores, Five Cores, Seven Cores &Â Twelve Cores.
Nexans H07RN-F Cable – Single Core |
|||||||
---|---|---|---|---|---|---|---|
Cross Section [mm²] | Current Rating Open Air [A] | Voltage Drop (1ph) [V/A·km] | Min. Outer Ø [mm] | Max. Outer Ø [mm] | Weight [kg/km] | Max. Resistance [Ω/km] | Nexans Ref. |
10 | 77 | 3.4 | 9.5 | 11.9 | 182 | 1.91 | 10056059 |
16 | 102 | 2.2 | 10.8 | 13.4 | 256 | 1.21 | 10056087 |
25 | 136 | 1.4 | 12.7 | 15.8 | 369 | 0.78 | 10055844 |
35 | 168 | 1.04 | 14.3 | 17.9 | 482 | 0.554 | 10056084 |
50 | 203 | 0.75 | 16.5 | 20.6 | 662 | 0.386 | 10055845 |
70 | 254 | 0.56 | 18.6 | 23.3 | 895 | 0.272 | 10056086 |
95 | 315 | 0.44 | 20.8 | 26.0 | 1144 | 0.206 | 10056088 |
120 | 363 | 0.36 | 22.8 | 28.6 | 1430 | 0.161 | 10056089 |
150 | 416 | 0.31 | 25.2 | 31.4 | 1740 | 0.129 | 10056129 |
185 | 475 | 0.28 | 27.6 | 34.4 | 2160 | 0.106 | 10044024 |
240 | 559 | 0.23 | 30.6 | 38.3 | 2730 | 0.0801 | 10044035 |
300 | 637 | 0.20 | 33.5 | 41.9 | 3480 | 0.0641 | 10044025 |
500 | 833 | 0.16 | 41.3 | 52.0 | 5700 | 0.0384 | 10056493 |
Nexans H07RN-F Cable – Two Cores |
|||||||
---|---|---|---|---|---|---|---|
Cross Section [mm²] | Current Rating Open Air [A] | Voltage Drop (1ph) [V/A·km] | Min. Outer Ø [mm] | Max. Outer Ø [mm] | Weight [kg/km] | Max. Resistance [Ω/km] | Nexans Ref. |
1.5 | 23 | 27.0 | 8.5 | 11.0 | 111 | 13.3 | 10056097 |
2.5 | 32 | 16.2 | 10.2 | 13.1 | 161 | 7.98 | 10056187 |
4 | 43 | 10.1 | 11.8 | 15.1 | 238 | 4.95 | 10056131 |
Nexans H07RN-F Cable – Three Cores |
|||||||
---|---|---|---|---|---|---|---|
Cross Section [mm²] | Current Rating Open Air [A] | Voltage Drop (1ph) [V/A·km] | Min. Outer Ø [mm] | Max. Outer Ø [mm] | Weight [kg/km] | Max. Resistance [Ω/km] | Nexans Ref. |
1.5 | 23 | 27.0 | 9.2 | 11.9 | 134 | 13.3 | 10056797 |
2.5 | 32 | 16.2 | 10.9 | 14.0 | 195 | 7.98 | 10056143 |
4 | 43 | 10.1 | 12.7 | 16.2 | 290 | 4.95 | 10056120 |
6 | 56 | 7.0 | 14.1 | 18.0 | 346 | 3.3 | 10055972 |
10 | 77 | 4.0 | 19.1 | 24.2 | 663 | 1.91 | 10056144 |
16 | 102 | 2.5 | 21.8 | 27.6 | 924 | 1.21 | 10056188 |
25 | 136 | 1.7 | 26.1 | 33.0 | 1345 | 0.78 | 10044017 |
35 | 168 | 1.21 | 29.3 | 37.1 | 1760 | 0.554 | 10056207 |
50 | 203 | 0.87 | 34.1 | 42.9 | 2390 | 0.386 | 10056092 |
70 | 262 | 0.64 | 38.4 | 48.3 | 3110 | 0.272 | 10056093 |
95 | 320 | 0.5 | 43.3 | 54.0 | 4170 | 0.206 | 10056191 |
Nexans H07RN-F Cable – Four Cores |
|||||||
---|---|---|---|---|---|---|---|
Cross Section [mm²] | Current Rating Open Air [A] | Voltage Drop (1ph) [V/A·km] | Min. Outer Ø [mm] | Max. Outer Ø [mm] | Weight [kg/km] | Max. Resistance [Ω/km] | Nexans Ref. |
1.5 | 21 | 23.3 | 10.2 | 13.1 | 165 | 13.3 | 10056102 |
2.5 | 29 | 14.0 | 12.5 | 15.5 | 245 | 7.98 | 10056137 |
4 | 38 | 8.71 | 14.0 | 18.0 | 357 | 4.95 | 10056051 |
6 | 50 | 5.84 | 15.7 | 20.0 | 443 | 3.3 | 10056046 |
10 | 68 | 3.42 | 20.8 | 26.5 | 818 | 1.91 | 10056109 |
16 | 92 | 2.2 | 23.8 | 30.1 | 1150 | 1.21 | 10056146 |
25 | 122 | 1.44 | 28.9 | 36.6 | 1700 | 0.78 | 10055848 |
35 | 150 | 1.04 | 32.5 | 41.1 | 2180 | 0.554 | 10055849 |
50 | 182 | 0.75 | 37.7 | 47.5 | 3030 | 0.386 | 10044032 |
70 | 232 | 0.56 | 42.7 | 54.0 | 3990 | 0.272 | 10056155 |
95 | 281 | 0.44 | 48.4 | 61.0 | 5360 | 0.206 | 10056189 |
120 | 325 | 0.36 | 53.0 | 66.0 | 6500 | 0.161 | 10056247 |
150 | 373 | 0.31 | 58.0 | 73.0 | 7990 | 0.129 | 10056211 |
150 | 373 | 0.31 | 58.0 | 73.0 | 7990 | 0.129 | 10278420 |
185 | 425 | 0.28 | 64.0 | 80.0 | 9910 | 0.106 | 10056248 |
Nexans H07RN-F Cable – Five Cores |
|||||||
---|---|---|---|---|---|---|---|
Cross Section [mm²] | Current Rating Open Air [A] | Voltage Drop (1ph) [V/A·km] | Min. Outer Ø [mm] | Max. Outer Ø [mm] | Weight [kg/km] | Max. Resistance [Ω/km] | Nexans Ref. |
1.5 | 21 | 23.6 | 11.2 | 14.4 | 238 | 13.3 | 10056106 |
2.5 | 29 | 14.0 | 13.3 | 17.0 | 297 | 7.98 | 10056126 |
6 | 50 | 5.84 | 17.5 | 22.2 | 557 | 3.3 | 10056154 |
10 | 68 | 3.43 | 22.9 | 29.1 | 1001 | 1.91 | 10056163 |
16 | 92 | 2.2 | 26.4 | 33.3 | 1430 | 1.21 | 10056158 |
25 | 122 | 1.44 | 32.0 | 40.4 | 2096 | 0.78 | 10056107 |
35 | 153 | 1.04 | – | 45.1 | 2716 | 0.554 | 10044018 |
50 | 187 | 1.04 | – | 53.0 | 3809 | 0.386 | 10056190 |
70 | 241 | 0.56 | – | 60.0 | 5087 | 0.272 | 10056218 |
Nexans H07RN-F Cable – Seven Cores</h4 |
|||||||
---|---|---|---|---|---|---|---|
Cross Section [mm²] | Current Rating Open Air [A] | Voltage Drop (1ph) [V/A·km] | Min. Outer Ø [mm] | Max. Outer Ø [mm] | Weight [kg/km] | Max. Resistance [Ω/km] | Nexans Ref. |
1.5 | 16 | 23.3 | 14.7 | 18.7 | 349 | 13.3 | 10056165 |
2.5 | 19 | 13.9 | 17.1 | 21.8 | 487 | 7.98 | 10056156 |
4 | 31 | 8.7 | 20.3 | 25.8 | 715 | 4.95 | 10056358 |
Nexans H07RN-F Cable – Twelve Cores |
|||||||
---|---|---|---|---|---|---|---|
Cross Section [mm²] | Current Rating Open Air [A] | Voltage Drop (1ph) [V/A·km] | Min. Outer Ø [mm] | Max. Outer Ø [mm] | Weight [kg/km] | Max. Resistance [Ω/km] | Nexans Ref. |
1.5 | 11 | 23.3 | 17.6 | 22.14 | 510 | 13.3 | 10056182 |
2.5 | 15 | 13.9 | 20.6 | 26.2 | 705 | 7.98 | 10044033 |
FAQs Nexans H07RN-F
How to install a H07RN-F cable?
H07RN-F cable is typically installed in mobile or fixed applications depending on its flexibility and protection level. It should be laid with care to avoid damage, and is suitable for use in dry, damp, or wet environments. When fixed and protected, it can withstand higher temperatures. Always follow local regulations and manufacturer guidelines during installation.
Max continuous operating conductor temperature in normal use :
- +60°C (in every case of mobile installation)
- +85°C (in fixed and protected installation)
- +200°C ( in short circuit )
What is the difference between H05RN-F and H07RN-F?
The difference between these two variants lies in voltage rating and durability. H05RN-F cables are rated for 300/500 V and used in light-duty, indoor applications, while H07RN-F cables are rated for 450/750 V and designed for heavy-duty, industrial use. H07RN-F is more robust, flexible, and suitable for outdoor and mobile installations.
What resistance/durability features does the Nexans H07RN-F have?
The Nexans H07RN-F cable offers excellent resistance to oil, water, UV rays, and mechanical impact. It’s designed for flexible use in harsh industrial and outdoor environments, including ATEX zones. The robust rubber insulation also provides reliable flame-retardant and abrasion-resistant performance under demanding conditions.
Order from our Nexans range
We’re long-time partners and suppliers of Nexans Euromold, market-leading manufacturers of LV MV HV power cables and cable accessories, such as cable connectors, joints and terminations. Thorne & Derrick offer exclusive Nexans pricing, excellent customer service and fast shipping, covering both UK orders and Export orders worldwide.
Ready to place an order, or still not quite sure if the Nexans H07RN-F is the suitable choice for your project? Our team of specialists are available on +44 (0) 117 935 9421, or click the button below to fill out a contact form with your enquiry. We provide engineered solutions and expert knowledge/advice – ensuring complete satisfaction and confidence with every order.