Ex e & Ex d Cable Gland ATEX & IECEx Explosive Atmospheres – CMP PX2KW/M

CMP PX2KW/M mining cable glands used to terminate Steel & Aluminium Wire Armoured cable in explosive atmospheres are ATEX & IECEx hazardous area certified – flameproof CMP PX2KW/M cable glands are available in brass, nickel plated brass and stainless steel for Ex e and EX d applications.

CMP PX2KW/M Cable Glands

  • CMP PX2KW/M cable glands permitted in Zone 1
  • Direct & remote installation
  • Compound barrier type flameproof seal
  • Controlled outer ‘load retention’ seal
  • Unique OSTG prevents overtightening
  • -60˚C to +85˚C
  •  Internationally marked, IECEx & ATEX CMP cable glands
  • EMC tested
CMP PX2KW/M Cable Glands

CMP PX2KW/M Cable Glands

CMP PX2KW/M Cable Glands specification

PX2KW/M Cable Gland Material: Brass, Electroless Nickel Plated Brass, Stainless Steel

Design Specification: BS 6121:Part 1:1989, IEC 62444, EN 62444

CMP Cable Gland Size Available Entry Threads “C” (Alternative Metric Thread Lengths Available) Maximum Number Of Cores Maximum Diameter Over Conductors “A” Cable Bedding Diameter “G” Overall Cable Diameter “B” Pliable Armour Wire Across Flats “D” Across Corners “D” Protrusion Length “F” Combined Ordering Reference (*Brass Metric) Shroud Cable Gland Weight (kgs)
Metric Thread Length (Metric) “E” NPT Thread Length (NPT) “E” Option: NPT Min Max Min Max
Max Max Size Type Ordering Suffix
20S M20 15.0 1/2” 19.9 3/4” 11 11.7 11.7 9.5 15.9 0.0 7/0.45 30.5 33.6 62.0 20S PX2KW/M 1RA PVC06 0.230
20 M20 15.0 1/2” 19.9 3/4” 11 12.6 12.9 12.5 20.9 0.0 7/0.45 30.5 33.6 63.0 20 PX2KW/M 1RA PVC06 0.240
25 M25 15.0 3/4” 20.2 1” 21 17.5 17.9 14.0 22.0 0.0 7/0.45 37.5 41.3 69.5 25 PX2KW/M 1RA PVC09 0.370
25S M25 15.0 3/4” 20.2 1” 21 17.5 17.9 18.2 26.2 0.0 7/0.45 37.5 41.3 69.5 25 PX2KW/M 1RA PVC09 0.370
32 M32 15.0 1” 25.0 1 1/4” 38 23.6 23.9 23.7 33.9 0.0 7/0.45 46.0 50.6 75.0 32 PX2KW/M 1RA PVC11 0.570
40 M40 15.0 1 1/4” 25.6 1 1/2” 59 30.0 30.3 27.9 40.4 0.0 7/0.71 55.0 60.5 75.0 40 PX2KW/M 1RA PVC15 0.800
50S M50 15.0 1 1/2” 26.1 2” 89 36.6 36.9 35.2 46.7 0.0 7/0.71 60.0 66.0 77.0 50S PX2KW/M 1RA PVC18 0.900
50 M50 15.0 2” 26.9 2 1/2” 89 41.0 41.3 40.4 53.0 0.0 7/0.71 70.1 77.1 77.0 50 PX2KW/M 1RA PVC21 1.190
63S M63 15.0 2” 26.9 2 1/2” 115 47.9 48.4 45.6 59.4 0.0 7/0.71 75.0 82.5 79.7 63S PX2KW/M 1RA PVC23 1.390
63 M63 15.0 2 1/2” 39.9 3” 115 53.7 54.0 54.6 65.8 0.0 7/0.71 80.0 88.0 80.3 63 PX2KW/M 1RA PVC25 1.410
75S M75 15.0 2 1/2” 39.9 3” 140 59.9 60.2 59.0 72.0 0.0 7/0.71 90.0 99.0 86.8 75S PX2KW/M 1RA PVC28 2.090
75 M75 15.0 3” 41.5 3 1/2” 140 64.2 64.2 66.7 78.4 0.0 7/0.71 100.0 110.0 88.3 75 PX2KW/M 1RA PVC30 2.540

ATEX Cable GlandsHazardous Area Classification

ATEX Certificate: SIRA13ATEX1072X

Code of Protection: ATEX M2 Ex d I Mb, Ex e I Mb

IECEx Certificate: IECEx SIR 13.0027X

Code of Protection: Ex d I Mb, Ex e I Mb

CMP PX2KW/M Cable Gland Dimensions

PX2KW/M Cable Glands - CMP

PX2KW/M Cable Glands – CMP

➡ For more cable terminations see Mining Cable Glands.

CMP Cable Glands

CMP Cable Glands – cable terminations for Industrial, High Voltage, Hazardous Area Explosive Atmospheres (ATEX & IECEx) & Group 1 Mining Cables  – including CIEL High Fault Current, SOLO Low Smoke Zero Halogen, ZEN Insulated & RapidEx Barrier Cable glands