A2EXP (NPT) Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 495NE)

A2EXP (NPT) Cable Glands – Flameproof Ex e/Ex d & Explosion Proof
A2EXP (NPT) Cable Glands from the Prysmian 495NE range of hazardous area cable glands suitable for terminating circular unarmoured cables in Zone 1 and Zone 2 locations – Prysmian A2EXP (NPT) cable glands provide high performance in high temperatures in deluge and IP68 conditions.
A2EXP (NPT) Cable Glands – Prysmian 495NE
Flameproof Ex e/Ex d Cable Glands & Kits
- A2EXP NPT brass indoor and outdoor hazardous area cable gland
- Suitable for circular unarmoured cables with extruded cable oversheath
- Cable gland fitted with silicone rubber low smoke, zero halogen seal
- IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to electrical enclosure with suitable sealing washer
- Weatherproof, waterproof and deluge proof cable gland
- Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
- Service temperature range -50°C to +200°C
- UL classified according to IEC60079-0, 60079-1 and 60079-7 for hazardous area locations
- UL listed glands for use in Class 1, Zone 0, 1 and 2 hazardous area locations (Canada)
- Nickel plated A2EXP NPT cable glands are available
➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.
Hazardous Area A2EXP (NPT) Cable Glands
PRYSMIAN 495NE
A2EXP (NPT) cable glands are suitable for use in:
- Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
- Zones 1 & 2 with Ex ib IIA, B & C Equipment
- Zones 1 & 2 with Ex e II Equipment
- Zones 1 & 2 with Ex p ΙΙ Equipment
- Zone 2 with Ex nA II Equipment
- Zones 21 & 22 with Ex tD II Equipment
Additionally, where the cable is effectively filled, the A2EXP cable glands can be used in:
- Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
- Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
- Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
- Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
- Zone 2 with Ex nR II Equipment
ATEX A2EXP (NPT) Cable Glands
ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.
Cables & Accessories for Hazardous Areas
T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats
Prysmian Bicon Cable Gland Reference | Cable Gland Size | Cable Dimensions (mm) | 495NE Cable Gland Dimensions (mm) | |||||||
Cable Diameter ∅ (B) mm | Entry Thread (D) | Thread Length (E) | Protrusion Length (F) | Hexagon | ||||||
Standard | Nickel Plated | Min | Max | A/F (G) | A/C (H) | |||||
495NE-03 | 495NE-03V | ½”- 16 | 3.5 | 8.5 | ½” NPT | 15.5 | 65 | 25.7 | 28.7 | |
495NE-04 | 495NE-04V | ½”- 20S | 8.0 | 11.5 | ½” NPT | 15.5 | 65 | 27.8 | 31.8 | |
495NE-05 | 495NE-05V | ½”- 20 | 8.0 | 16.0 | ½” NPT | 15.5 | 62 | 33 | 36.9 | |
495NE-08 | 495NE-08V | ¾” – 20 | 8.0 | 16.0 | ¾” NPT | 16.4 | 62 | 33 | 36.9 | |
495NE-10 | 495NE-10V | ¾” – 25 | 11.5 | 21.0 | ¾” NPT | 16.4 | 81 | 33 | 36.9 | |
495NE-14 | 495NE-14V | 1” – 25 | 11.5 | 21.0 | 1” NPT | 19.5 | 81 | 37.5 | 42.2 | |
495NE-15 | 495NE-15V | 1” – 32 | 18.5 | 27.5 | 1” NPT | 19.5 | 69 | 37.5 | 42.2 | |
495NE-20 | 495NE-20V | 1¼” – 32 | 18.5 | 27.5 | 1¼” NPT | 20.5 | 69 | 47.2 | 52.9 | |
495NE-21 | 495NE-21V | 1¼” – 40 | 24.0 | 34.0 | 1¼” NPT | 20.5 | 82 | 47.2 | 53.6 | |
495NE-27 | 495NE-27V | 1 ½” – 40 | 24.0 | 34.0 | 1½” NPT | 21 | 82 | 56.4 | 63.1 | |
495NE-32 | 495NE-32V | 2” – 50 | 31.0 | 41.0 | 2” NPT | 22 | 79 | 65 | 71.5 | |
495NE-38 | 495NE-38V | 2½” – 63 | 40.0 | 52.5 | 2½” NPT | 32.5 | 113.5 | 80 | 87.4 | |
495NE-44 | 495NE-44V | 3” – 75S | 52.5 | 58.0 | 3” NPT | 33.5 | 78.5 | 98.8 | 109.2 | |
495NE-45 | 495NE-45V | 3”- 75 | 54.5 | 65.5 | 3” NPT | 33.5 | 120 | 98.8 | 109.2 |
*NPT threaded cable glands are supplied as glands only. **Other NPT sizes available upon request.

Onshore & Offshore Cables For Hazardous Areas

A2EXP (NPT) Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 495NE)

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof