A2EX (NPT) Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 494NE)

View Sub Products

A2EX (NPT) Cable Glands - Hazardous Area Exd IIC Ex e II (Prysmian 494NE)

A2EX (NPT) Cable Glands – Flameproof Ex e/Ex d & Explosion Proof

A2EX (NPT) Cable Glands from the Prysmian 494NE range of hazardous area cable glands suitable for terminating circular unarmoured cables in Zone 1 and Zone 2 locations – Prysmian A2EX (NPT) cable glands provide high performance in high temperatures in deluge and IP68 conditions.

A2EX (NPT) Cable Glands – Prysmian 494NE

Flameproof Ex e/Ex d Cable Glands & Kits
  • A2EX NPT brass indoor and outdoor hazardous area cable gland
  • Suitable for circular unarmoured cables with extruded cable oversheath
  • Cable gland fitted with silicone rubber low smoke, zero halogen seal
  • IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to electrical enclosure with suitable sealing washer
  • Weatherproof, waterproof and deluge proof cable gland
  • Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
  • Service temperature range -50°C to +200°C
  • UL classified according to IEC60079-0, 60079-1 and 60079-7 for hazardous area locations
  • UL listed glands for use in Class 1, Zone 0, 1 and 2 hazardous area locations (Canada)
  • Nickel plated A2EX NPT cable glands are available

➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.

Hazardous Area A2EX (NPT) Cable Glands

PRYSMIAN 494NE

Hazardous Area Zone 1 Zone 2 Cable Glands

A2EX (NPT) cable glands are suitable for use in:

  • Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
  • Zones 1 & 2 with Ex ib IIA, B & C Equipment
  • Zones 1 & 2 with Ex e II Equipment
  • Zones with Ex nA II Equipment
  • Zones 21 & 22 with Ex tD II Equipment

Additionally, where the cable is effectively filled, the A2EX cable glands can be used in:

  • Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
  • Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
  • Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
  • Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
  • Zone 2 with Ex nR II Equipment

ATEX A2EX (NPT) Cable Glands

ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.

 

Hazardous Cable Glands Prysmian

Cables & Accessories for Hazardous Areas

T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats

Prysmian Bicon Cable Gland Reference Cable Gland Size Cable Dimensions (mm) 494NE Cable Gland Dimensions (mm)
Cable Diameter ∅ (B) mm Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon
Standard Nickel Plated Min Max A/F (G) A/C (H)
494NE-03 494NE-03V ½”- 16 3.5 8.5 ½” NPT 15.5 36 25.7 28.7
494NE-04 494NE-04V ½”- 20S 8.0 11.5 ½” NPT 15.5 36 27.8 31.8
494NE-05 494NE-05V ½”- 20 8.0 16.0 ½” NPT 15.5 34 33 36.9
494NE-08 494NE-08V ¾” – 20 8.0 16.0 ¾” NPT 16.4 34 33 36.9
494NE-10 494NE-10V ¾” – 25 11.5 21.0 ¾” NPT 16.4 44 33 36.9
494NE-14 494NE-14V 1” – 25 11.5 21.0 1” NPT 19.5 44 37.5 42.2
494NE-15 494NE-15V 1” – 32 18.5 27.5 1” NPT 19.5 38 37.5 42.2
494NE-20 494NE-20V 1¼” – 32 18.5 27.5 1¼” NPT 20.5 38 47.2 52.9
494NE-21 494NE-21V 1¼” – 40 24.0 34.0 1¼” NPT 20.5 46 47.2 53.6
494NE-27 494NE-27V 1 ½” – 40 24.0 34.0 1½” NPT 21 46 56.4 63.1
494NE-32 494NE-32V 2” – 50 31.0 41.0 2” NPT 22 44 65 71.5
494NE-38 494NE-38V 2½” – 63 40.0 52.5 2½” NPT 32.5 61 80 87.4
494NE-44 494NE-44V 3” – 75S 52.5 58.0 3” NPT 33.5 46 98.8 109.2
494NE-45 494NE-45V 3”- 75 54.5 65.5 3” NPT 33.5 66 98.8 109.2

*NPT threaded cable glands are supplied as glands only. **Other NPT sizes available upon request.

A2EX (NPT) Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian 494NE)

A2EX (NPT) Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 494NE)

Hazardous Area Offshore - Cables Joints Glands Cleats MV HV

Onshore & Offshore Cables For Hazardous Areas

Hazardous Area Cable Glands

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof