E1WF-AL Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian KCA455)

View Sub Products

E1WF-AL Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian KCA455)

E1WF-AL Cable Glands – Flameproof Ex e/Ex d & Explosion Proof

E1WF-AL Cable Glands from the Prysmian KCA455 range of hazardous area cable glands suitable for terminating circular aluminium wire armoured cables in Zone 1 and Zone 2 locations – Prysmian E1WF-AL cable glands provide high performance in high temperatures and achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant.

E1WF-AL Cable Glands – Prysmian KCA455

Flameproof Ex e/Ex d Cable Glands & Kits
  • E1WF-AL aluminium indoor and outdoor hazardous area cable gland
  • Suitable for circular armoured cables with extruded cable with extruded polymeric bedding and oversheath
  • Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant
  • Weatherproof & waterproof cable gland
  • Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
  • Inner PCP seal grips cable bedding and provides additional ingress protection
  • Three part armour lock provides mechanical cable retention and electrical continuity
  • Service temperature range -60°C to +90°C
  • ATEX Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1

➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.

Hazardous Area E1wF-AL Cable Glands

PRYSMIAN KCA455

Hazardous Area Zone 1 Zone 2 Cable Glands

E1WF-AL cable glands are suitable for use in:

  • Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
  • Zones 1 & 2 with Ex ib IIA, B & C Equipment
  • Zones 1 & 2 with Ex e II Equipment
  • Zone 2 with Ex nA II Equipment
  • Zones 21 & 22 with Ex tD II Equipment

Additionally, where the cable is effectively filled, the E1WF-AL cable glands can be used in:

  • Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
  • Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
  • Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
  • Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
  • Zone 2 with Ex nR II Equipment

ATEX E1WF-AL Cable Glands

ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.

 

Hazardous Cable Glands Prysmian

Cables & Accessories for Hazardous Areas

T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats

Prysmian Bicon Cable Gland Reference Cable Gland Size Cable Dimensions (mm) KCA455 Cable Gland Dimensions (mm)
Under Armour Ø (A) Overall Ø (B) Armour Wire Ø Pack Quantity Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon
Standard Min Max Min Max A/F (G) A/C (H)
KCA455-51 16 3.8 8.7 8.0 13.2 0.9 2 M16×1.5 15 41 23.4 26.7
KCA455-71 20SS 3.8 8.7 8.0 13.2 0.9 2 M20×1.5 15 41 23.4 26.7
KCA455-52 20S 8.0 11.8 8.0 15.8 0.9 /1.25 2 M20×1.5 15 43 25.7 29.2
KCA455–53 20 11.8 14.2 11.7 20.8 0.9 /1.25 2 M20×1.5 15 43 30.5 34.0
KCA455–55 25 14.0 20.1 17.0 27.2 1.25 / 1.6 2 M25×1.5 15 48 37.6 42.2
KCA455–56 32 19.7 26.6 23.5 33.5 1.6 / 2.0 1 M32×1.5 15 53 47.2 53.6
KCA455–57 40 26.6 32.4 29.0 39.9 1.6 / 2.0 1 M40×1.5 15 56 56.4 61.5
KCA455-58 50S 32.4 38.4 38.0 46.2 2.0 / 2.5 1 M50×1.5 15 61 60.0 66.0
KCA455–59 50 38.4 44.3 39.5 52.6 2.0 / 2.5 1 M50×1.5 15 61 70.1 77.2
KCA455–60 63S 44.3 50.3 50.0 58.9 2.5 1 M63×1.5 15 64 75.0 83.0
KCA455–61 63 50.3 56.2 51.3 65.3 2.5 1 M63×1.5 15 64 80.0 87.4
KCA455–62 75S 56.2 62.2 62.0 71.6 2.5 1 M75x1.5 15 73 90.2 99.1
KCA455–63 75 62.2 68.1 62.5 78.0 2.5 1 M75x1.5 15 73 98.8 109.2
KCA455–64 85 68.0 74.0 68.0 88.0 3.15 1 M85x1.5 20 102 115.1 126.0
E1WF-AL Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian KCA455)

E1WF-AL Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian KCA455)

Hazardous Area Offshore - Cables Joints Glands Cleats MV HV

Onshore & Offshore Cables For Hazardous Areas

Hazardous Area Cable Glands

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof