E1WF Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian KCA472)

E1WF Cable Glands – Flameproof Ex e/Ex d & Explosion Proof
E1WF Cable Glands from the Prysmian KCA472 range of hazardous area cable glands suitable for terminating circular steel wire armoured cables in Zone 1 and Zone 2 locations – Prysmian E1WF cable glands provide high performance in high temperatures and achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant.
E1WF Cable Glands –Â Prysmian KCA472
Flameproof Ex e/Ex d Cable Glands & Kits
- E1WF brass indoor and outdoor hazardous area cable gland
- Suitable for circular armoured cables with extruded cable with extruded polymeric bedding and oversheath
- Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant
- Weatherproof & waterproof cable gland
- Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
- Inner PCP seal grips cable bedding and provides additional ingress protection
- Three part armour lock provides mechanical cable retention and electrical continuity
- Service temperature range -60°C to +90°C
- ATEX Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1
- IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1
- Nickel plated E1WF cable glands are available
➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.
Hazardous Area E1wF Cable Glands
PRYSMIAN KCa472
E1WF cable glands are suitable for use in:
- Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
- Zones 1 & 2 with Ex ib IIA, B & C Equipment
- Zones 1 & 2 with Ex e II Equipment
- Zone 2 with Ex nA II Equipment
- Zones 21 & 22 with Ex tD II Equipment
Additionally, where the cable is effectively filled, the E1WF cable glands can be used in:
- Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
- Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
- Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
- Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
- Zone 2 with Ex nR II Equipment
ATEX E1WF Cable Glands
ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.
Cables & Accessories for Hazardous Areas
T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats
Prysmian Bicon Cable Gland Reference | Cable Gland Size | Cable Dimensions (mm) | E1WF Cable Gland Dimensions (mm) | ||||||||||||||||||||
Under Armour Ø (A) | Overall Ø (B) | Armour Wire Ø | Pack Quantity | Entry Thread (D) | Thread Length (E) | Protrusion Length (F) | Hexagon | ||||||||||||||||
Standard | Nickel Plated | Min | Max | Min | Max | A/F (G) | A/C (H) | ||||||||||||||||
KCA472-51 | KCA472-51V | 16 | 3.8 | 8.7 | 8.0 | 13.2 | 0.9 | 2 | M16×1.5 | 15 | 41 | 23.4 | 26.7 | ||||||||||
KCA472-71 | KCA472-71V | 20SS | 3.8 | 8.7 | 8.0 | 13.2 | 0.9 | 2 | M20×1.5 | 15 | 41 | 23.4 | 26.7 | ||||||||||
KCA472-52 | KCA472-52V | 20S | 8.0 | 11.8 | 8.0 | 15.8 | 0.9 /1.25 | 2 | M20×1.5 | 15 | 43 | 25.7 | 29.2 | ||||||||||
KCA472–53 | KCA472–53V | 20 | 11.8 | 14.2 | 11.7 | 20.8 | 0.9 /1.25 | 2 | M20×1.5 | 15 | 43 | 30.5 | 34.0 | ||||||||||
KCA472–55 | KCA472–55V | 25 | 14.0 | 20.1 | 17.0 | 27.2 | 1.25 / 1.6 | 2 | M25×1.5 | 15 | 48 | 37.6 | 42.2 | ||||||||||
KCA472–56 | KCA472–56V | 32 | 19.7 | 26.6 | 23.5 | 33.5 | 1.6 / 2.0 | 1 | M32×1.5 | 15 | 53 | 47.2 | 53.6 | ||||||||||
KCA472–57 | KCA472–57V | 40 | 26.6 | 32.4 | 29.0 | 39.9 | 1.6 / 2.0 | 1 | M40×1.5 | 15 | 56 | 56.4 | 61.5 | ||||||||||
KCA472-58 | KCA472-58V | 50S | 32.4 | 38.4 | 38.0 | 46.2 | 2.0 / 2.5 | 1 | M50×1.5 | 15 | 61 | 60.0 | 66.0 | ||||||||||
KCA472–59 | KCA472–59V | 50 | 38.4 | 44.3 | 39.5 | 52.6 | 2.0 / 2.5 | 1 | M50×1.5 | 15 | 61 | 70.1 | 77.2 | ||||||||||
KCA472–60 | KCA472-60V | 63S | 44.3 | 50.3 | 50.0 | 58.9 | 2.5 | 1 | M63×1.5 | 15 | 64 | 75.0 | 83.0 | ||||||||||
KCA472–61 | KCA472–61V | 63 | 50.3 | 56.2 | 51.3 | 65.3 | 2.5 | 1 | M63×1.5 | 15 | 64 | 80.0 | 87.4 | ||||||||||
KCA472–62 | KCA472–62V | 75S | 56.2 | 62.2 | 62.0 | 71.6 | 2.5 | 1 | M75x1.5 | 15 | 73 | 90.2 | 99.1 | ||||||||||
KCA472–63 | KCA472–63V | 75 | 62.2 | 68.1 | 62.5 | 78.0 | 2.5 | 1 | M75x1.5 | 15 | 73 | 98.8 | 109.2 | ||||||||||
KCA472–64 | KCA472–64V | 85 | 68.0 | 74.0 | 68.0 | 88.0 | 3.15 | 1 | M85x1.5 | 20 | 102 | 115.1 | 126.0 |

E1WF Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian KCA472)

Onshore & Offshore Cables For Hazardous Areas

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof