E1WF (NPT) Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 472NP)

View Sub Products

E1WF (NPT) Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian 472NP)

E1WF Cable Glands – Flameproof Ex e/Ex d & Explosion Proof

E1WF NPT Cable Glands from the Prysmian 472NP range of hazardous area cable glands suitable for terminating circular steel wire armoured cables in Zone 1 and Zone 2 locations – Prysmian E1WF NPT cable glands provide high performance in high temperatures and achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant.

E1WF NPT Cable Glands – Prysmian 472NP

Flameproof Ex e/Ex d Cable Glands & Kits
  • E1WF NPT brass indoor and outdoor hazardous area cable gland
  • Suitable for circular armoured cables with extruded cable with extruded polymeric bedding and oversheath
  • Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant
  • Weatherproof & waterproof cable gland
  • Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
  • Inner PCP seal grips cable bedding and provides additional ingress protection
  • Three part armour lock provides mechanical cable retention and electrical continuity
  • Service temperature range -60°C to +90°C
  • ATEX Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1
  • Nickel plated E1WF NPT cable glands are available

➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.

Hazardous Area E1wF NPT Cable Glands

PRYSMIAN 472NP

Hazardous Area Zone 1 Zone 2 Cable Glands

E1WF NPT cable glands are suitable for use in:

  • Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
  • Zones 1 & 2 with Ex ib IIA, B & C Equipment
  • Zones 1 & 2 with Ex e II Equipment
  • Zones with Ex nA II Equipment
  • Zones 21 & 22 with Ex tD II Equipment

Additionally, where the cable is effectively filled, the E1WF NPT cable glands can be used in:

  • Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
  • Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
  • Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
  • Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
  • Zone 2 with Ex nR II Equipment

ATEX E1WF NPT Cable Glands

ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.

 

Hazardous Cable Glands Prysmian

Cables & Accessories for Hazardous Areas

T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats

Prysmian Bicon Cable Gland Reference Cable Gland Size Cable Dimensions (mm) E1WF Cable Gland Dimensions (mm)
Under Armour Ø (A) Overall Ø (B) Armour Wire Ø Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon
Standard Nickel Plated Min Max Min Max A/F (G) A/C (H)
472NP-03 472NP-03V ½”- 16 3.8 8.7 8.0 13.2 0.9 ½” NPT 15.5 41 23.4 26.7
472NP-04 472NP-04V ½”- 20S 8.0 8.7 8.0 15.8 0.9 /1.25 ½” NPT 15.5 43 25.7 29.2
472NP-07 472NP-07V ¾” – 20S 8.0 11.8 8.0 15.8 0.9 /1.25 ¾” NPT 16.4 43 27.9 31.8
472NP-05 472NP-05V ½”- 20 11.8 14.2 11.7 20.8 0.9 /1.25 ½” NPT 15.5 43 30.5 34.0
472NP-08 472NP-08V ¾” – 20 11.8 20.1 11.7 20.8 0.9 /1.25 ¾” NPT 16.4 43 30.5 34.0
472NP-10 472NP-10V ¾” – 25 14.0 26.6 17.0 27.2 1.25 / 1.6 ¾” NPT 16.4 48 37.6 42.2
472NP-14 472NP-14V 1” – 25 14.0 32.4 17.0 27.2 1.25 / 1.6 1” NPT 19.5 48 37.6 42.2
472NP-15 472NP-15V 1” – 32 19.7 38.4 23.5 33.5 1.6 / 2.0 1” NPT 19.5 53 47.2 53.6
472NP-20 472NP-20V 1¼” – 32 19.7 44.3 23.5 33.5 1.6 / 2.0 1¼” NPT 20.5 53 47.2 53.6
472NP-21 472NP-21V 1¼” – 40 26.6 50.3 29.0 39.9 1.6 / 2.0 1¼” NPT 20.5 56 56.4 61.5
472NP-27 472NP-27V 1½” – 40 26.6 56.2 29.0 39.9 1.6 / 2.0 1½” NPT 21 56 56.4 61.5
472NP-28 472NP-28V 1½”- 50S 32.4 62.2 38.0 46.2 2.0 / 2.5 1½” NPT 21 61 60.0 66.0
472NP-31 472NP-31V 2″ – 50S 32.4 68.1 38.0 46.2 2.0 / 2.5 2” NPT 22 61 65.5 72.1
472NP-32 472NP-32V 2″ – 50 38.4 74.0 39.5 52.6 2.0 / 2.5 2” NPT 22 61 70.1 77.2
472NP-33 472NP-33V 2″ – 63S 44.3 68.1 50.0 58.9 2.5 2” NPT 22 64 75.0 83.0
472NP-38 472NP-38V 2½” – 63 50.3 74.0 51.3 65.3 2.5 2½” NPT 32.5 64 80.0 87.4
472NP-39 472NP-39V 2½” – 75S 56.2 68.1 62.0 71.6 2.5 2½” NPT 32.5 73 90.2 99.1
472NP-45 472NP-45V 3″- 75 62.2 74.0 62.5 78.0 2.5 3” NPT 32.5 73 98.8 109.2
472NP-47 472NP-47V 3″- 80 68.0 68.1 68.0 88.0 3.15 3” NPT 32.5 102 115.1 126.0
E1WF (NPT) Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian 472NP)

E1WF (NPT) Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 472NP)

Hazardous Area Offshore - Cables Joints Glands Cleats MV HV

Onshore & Offshore Cables For Hazardous Areas

Hazardous Area Cable Glands

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof