Substation Earthing for Low, Medium & High Voltage Systems | CPD Training By EA Technology

Published 25 Jan 2022

Substation Earthing

Substation Earthing for Low, Medium & High Voltage Systems

Substation Earthing

EA Technology – CPD Training

Cost: £1220

Course Duration:  3 Days

Course Location: Capenhurst, Chester

Dates: 17th-19th May 2022

CPD Information: 18 Hours

Sign Up Here: https://eatechnology.com/training/scheduled-courses/substation-courses/substation-earthing/


Day one

Introduction and Principles of Earthing in LV, MV and HV Systems

  • Role, principles and importance of earthing
  • Preventing electric shock in LV systems
  • Earth faults, fault voltages, EPR and voltage gradient in MV and HV systems
  • Impedance in earthing and bonding conductors
  • Important criteria for earthing assessment

LV Earth Systems and Earth Terminals

  • Earthing requirements for public LV systems
  • Earth terminals for supply points in public and private LV cable systems
  • Abnormal voltages on LV earth terminals
  • Requirement to separate HV and LV earth systems
  • Special LV earthing situations

Earth Fault Current and EPR Analysis

  • System earthing
  • Redial and non-radial systems
  • Simplified and rigorous fault current analysis
  • Data and accuracy for project and EPR assessments

Introduction to Earth Standards and Company Earthing Policies

  • The need for standards and company procedures
  • The voltages and environmental impact that occur during earth fault at a substation
  • Description of safety voltages, limit values and ways they are constrained
  • Developments in ENA S34 and 14-24

Introduction to Earthing Design

  • Earthing standards; how this guides design practice
  • Main design criteria
  • Introduction to earth resistance formulae
  • Comparison of ways to reduce the earth resistance

Day two

Design of Substation Earthing

  • Stages in the design of a LV distribution substation
  • Use of standard formulae to investigate design options and check compliance
  • Design of the local substation electrode system
  • Design of the earthing system for a HV substation
  • Exercise in developing the outline electrode design

Measurement Theory

  • Earth resistivity
  • Earth resistance

Practical Measurement Exercise

  • Group exercise undertaking soil resistivity and electrode resistance measurements

Analysis of Measurement Data

  • Delegates will use specialist software to gain a derived soil model for design purposes
  • Analysis of electrode resistance data to calculate the true resistance of the measured earthing system

Day three

Industrial Site Measurement Case Study

  • Undertaking measurements in difficult locations
  • Highlight the important issues
  • Explanation of procedures

Analysis of Earth Fault Current and EPR in more Complex Network Arrangements

  • Network calculation procedures
  • Mixed underground and overhead systems and isolated cable sections in overhead lines
  • Identifying points of worst case EPR

Example Case Studies and Calculations of EPR and risk effects in Industrial, generation and public HV and MV Systems

  • Generation and industrial sites connected to cable and overhead line systems
  • Separation of HV/MV and LV earth systems in high resistivity areas
  • LV installations in vicinity of HV equipment with high EPR

Course Review

Programme may be subject to amendment.


Why Should I Attend?

  • Enhance your knowledge of earthing principles and systems
  • Understand the legal and environmental framework and standards that apply to earthing systems
  • Develop your ability to specify earthing system design to current standards
  • Reduce the risk of critical system failure through enhanced design
  • Enhance your understanding of the role of earthing systems in safe working practices
  • Enhance your understanding of earthing measurement processes and the analysis of measurement data
  • Develop knowledge of managing earthing system design and maintenance projects

This course is delivered by leading specialists in earthing assessment, design and audit and draws on their extensive expertise in the field.

Click Here To Sign Up Today


Testimonials

‟Fascinating course due to the extensive knowledge of the presenter. Lots of myths debunked!! Enough knowledge attained to be able to challenge consultant designers and know the right questions to ask. Undoubtedly a good investment in time.”

Ade

15-17 June 2021

‟Definitely improved my technical knowledge of more up to date modern thinking & the standards used within the UK. Very informative, even though the formulas slightly taxing as I am 35 years since being in any educational, academic faculty. Presenters were very good & very approachable. Thanks.”

Paul

15-17 June 2021

‟Extremely informative, well presented and well organised. Thank you. ”

Tom

15-17 June 2021

‟Extremely informative.”

Jim

15-17 June 2021

‟Good course, expanded my knowledge considerably.”

Michael

15-17 June 2021


EA Technology

EA Technology - Substation Earthing

EA Technology are a global provider of end to end power engineering solutions and provide expert consultancy, innovative instruments, skills training, technical services and more.

William G. Higinbotham has been president of EA Technology LLC since 2013. His responsibilities involve general management of the company, including EA Technology activities in North and South America. William is also responsible for sales, service, support, and training on partial discharge instruments and condition-based asset management. He is the author or co-author of several industry papers.


QT-III Cold Shrink Terminations

Supplying Cable Termination, Jointing, Pull-in & Electrical Equipment up to 66kV

Thorne & Derrick distribute the most extensive range of MV HV Medium & High Voltage Cable Joints, Terminations & Connectors from manufacturers including 3M, Prysmian, Nexans Euromold, Elastimold, Pfisterer CONNEX and Shrink Polymer Systems.

Heat shrink, cold shrink, push-on and slip-over cable accessories enable the jointing, terminating and connection of 11kV-33kV and 66kV-132kV cables to oil, air or gas insulated switchgear, transformers, motors and overhead lines distributing electricity at MV HV.

3M Nexans Pfisterer

MV HV High Voltage Cable Joints | Cable Terminations | Cable Connectors | Distributed from Stock | UK & Export Sales