BS EN 62305

AN Wallis manufacture earth tapes from high conductivity copper to ensure LPS designs and installations conform to latest Britsh and International standards
Uploaded by Chris Dodds - Thorne & Derrick Sales & Marketing Manager
The Part 2 of BS EN 62305 provides a comprehensive mathematical model to evaluate and manage the risk posed by lightning strikes and measures to alleviate the risk associated with earthing system designs.
The risk assessment is extremely time consuming to calculate by hand so Wallis, working in conjunction with their distributor Thorne & Derrick International, can offer to do the assessment using bespoke computer software.
The basics of the calculation can be briefly explained as follows taking into account:
The Sources of Lightning
The Likely Damage
The Likely Losses
The following Table 2 from BS EN 62305 explains the link between Sources, Damages & Losses.
Sources of damage, types of damage and types of loss according to the point of strike:
| Lightning Flash | Structure | |
| Source of Damage | Type of Damage | 1 Type of Loss |
| S1 | D1D2D3 | L1, L4aL1, L2, L3, L4 L1b, L2, L4 |
| S2 | D3 | L1b, L2, L4 |
| S3 | D1D2D3 | L1, L4a,L1, L2, L3,L4Â Lib, L2, L4 |
| S4 | D3 | L1b, L2, L4 |
Note:
a) Only for properties where animals may be lost.
b) Only for structures with risk of explosion and for hospitals or other structures where failures of internal systems immediately endangers human
Risk: The risks to be evaluated in a structure may be as follows
Risk Management
The following procedure shall be applied:
Protection does not include connected lines outside of the structure.
The calculated risks R1, R2 & R3 shall be compared with tolerable risk. The permissible values for the tolerable risk are mentioned in the Table 4 BS EN 62305.
| Types of Loss | RT (y-1) | |
| L1 | Loss of human life or permanent injuries | 10-5 |
| L2 | Loss of service to the public | 10-4 |
| L3 | Loss of cultural heritage | 10-4 |
If R < RT, lightning protection is not necessary. If R > RT, protection measures shall be adopted in order to reduce R RT for all risks to which the structure is subjected.
The manual calculations are time consuming. It is recommended to use available Lightning Protection Risk Management Software to perform these calculations – contact T&D.

Contact us to discuss all your Substation Earthing, Cable Jointing & Terminating requirements for the installation of LV MV HV cables, copper earthing tapes and infrastructure including switchgear, transformers and electrical equipment up to 33kV.
Product Categories: Duct Seals | Cable Cleats | Cable Glands | Electrical Safety | Arc Flash Protection | Cable Jointing Tools | Cable Pulling | Earthing | Feeder Pillars | Cable Joints LV | Joints & Terminations MV HVÂ

Largest UK Stocks Of Copper Earthing Tapes

Earth Rods | Earth Bars | Earth Mats | Earth Clamps – manufactured from high conductivity copper by AN Wallis and supplied by Thorne & Derrick
Published 09 Jan 2026
We’d like to welcome our newest addition to the Thorne and Derrick team! Eva will be joining us as a content creator apprentice at our office in Chester-Le-Street. Eva will bring fresh new ideas to all of our social...
Published 09 Jan 2026
Insulating Matting Recommendations and Guidance for Electrical Safety Guest Blog From COBA Electrical safety is non-negotiable, especially when working around live switchgear, high-voltage panels, and electrical distribution equipment. One critical but sometimes overlooked safeguard is electrical insulating matting, designed...