A2EX Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian KM494)

View Sub Products

A2EX Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian KM494)

A2EX Cable Glands – Flameproof Ex e/Ex d & Explosion Proof

A2EX Cable Glands from the Prysmian KM494 range of hazardous area cable glands suitable for terminating circular unarmoured cables in Zone 1 and Zone 2 locations – Prysmian A2EX cable glands provide high performance in high temperatures in deluge and IP68 conditions.

A2EX Cable Glands – Prysmian KM494

Flameproof Ex e/Ex d Cable Glands & Kits
  • A2EX brass indoor and outdoor hazardous area cable gland
  • Suitable for circular unarmoured cables with extruded cable oversheath
  • Cable gland fitted with silicone rubber low smoke, zero halogen seal
  • IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to electrical enclosure with suitable sealing washer
  • Weatherproof, waterproof and deluge proof cable gland
  • Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
  • Service temperature range -50°C to +200°C
  • UL Classified in accordance with IEC 60079-0, 60079-1 and 60079-7 for use in hazardous locations
  • UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada
  • Nickel plated A2EX cable glands are available

➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.

Hazardous Area A2EX Cable Glands

PRYSMIAN KM494

Hazardous Area Zone 1 Zone 2 Cable Glands

A2EX cable glands are suitable for use in:

  • Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
  • Zones 1 & 2 with Ex ib IIA, B & C Equipment
  • Zones 1 & 2 with Ex e II Equipment
  • Zones 1 & 2 with Ex p ΙΙ Equipment
  • Zones with Ex nA II Equipment
  • Zones 21 & 22 with Ex tD II Equipment

Additionally, where the cable is effectively filled, the A2EX cable glands can be used in:

  • Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
  • Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
  • Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
  • Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
  • Zone 2 with Ex nR II Equipment

ATEX A2EX Cable Glands

ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.

 

Hazardous Cable Glands Prysmian

Cables & Accessories for Hazardous Areas

T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats

Prysmian Bicon Cable Gland Reference Cable Gland Size Cable Dimensions (mm) KM494 Cable Gland Dimensions (mm)
Cable Diameter ∅ (B) mm Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon
Standard Nickel Plated Quantity per Kit Min Max A/F (G) A/C (H)
KM494-51 KM494-51V 2 16 3.5 8.5 M16×1.5 15 36 22 24.9
KM494-71 KM494-71V 2 20SS 3.5 8.5 M20×1.5 15 36 22 24.9
KM494-52 KM494-52V 2 20S 8.0 11.5 M20×1.5 15 34 22 24.9
KM494-53 KM494-53V 2 20 8.0 16.0 M20×1.5 15 34 25.7 28.7
KM494-55 KM494-55V 2 25 11.5 21.0 M25×1.5 15 44 33 36.9
KM494-56 KM494-56V 1 32 18.5 27.5 M32×1.5 15 38 37.5 45.2
KM494-57 KM494-57V 1 40 24.0 34.0 M40×1.5 15 46 47.2 53.6
KM494-59 KM494-59V 1 50 31.0 41.0 M50×1.5 15 44 56.4 61.5
KM494-61 KM494-61V 1 63 40.0 52.5 M63×1.5 15 61 70 77.2
KM494-62 KM494-62V 1 75S 52.5 58.0 M75×1.5 15 46 80 87.4
KM494-63 KM494-63V 1 75 54.5 65.5 M75×1.5 15 44 80 87.4
A2EX Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian KM494)

A2EX Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian KM494)

Hazardous Area Offshore - Cables Joints Glands Cleats MV HV

Onshore & Offshore Cables For Hazardous Areas

Hazardous Area Cable Glands

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof