E1WF Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 472AA)

View Sub Products

E1WF Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian 472AA)

E1WF Cable Glands – Flameproof Ex e/Ex d & Explosion Proof

E1WF Cable Glands from the Prysmian 472AA range of hazardous area cable glands suitable for terminating circular steel wire armoured cables in Zone 1 and Zone 2 locations – Prysmian E1WF cable glands provide high performance in high temperatures and achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant.

E1WF Cable Glands – Prysmian 472AA

Flameproof Ex e/Ex d Cable Glands & Kits
  • E1WF brass indoor and outdoor hazardous area cable gland
  • Suitable for circular armoured cables with extruded cable with extruded polymeric bedding and oversheath
  • Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant
  • Weatherproof & waterproof cable gland
  • Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
  • Inner PCP seal grips cable bedding and provides additional ingress protection
  • Three part armour lock provides mechanical cable retention and electrical continuity
  • Service temperature range -60°C to +90°C
  • ATEX Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1
  • Nickel plated E1WF cable glands are available

➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.

Hazardous Area E1wF Cable Glands

PRYSMIAN 472AA

Hazardous Area Zone 1 Zone 2 Cable Glands

E1WF cable glands are suitable for use in:

  • Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
  • Zones 1 & 2 with Ex ib IIA, B & C Equipment
  • Zones 1 & 2 with Ex e II Equipment
  • Zone 2 with Ex nA II Equipment
  • Zones 21 & 22 with Ex tD II Equipment

Additionally, where the cable is effectively filled, the E1WF cable glands can be used in:

  • Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
  • Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
  • Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
  • Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
  • Zone 2 with Ex nR II Equipment

ATEX E1WF Cable Glands

ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.

 

Hazardous Cable Glands Prysmian

Cables & Accessories for Hazardous Areas

T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats

Prysmian Bicon Cable Gland Reference Cable Gland Size Cable Dimensions (mm) E1WF Cable Gland Dimensions (mm)
Under Armour Ø (A) Overall Ø (B) Armour Wire Ø Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon
Standard Nickel Plated Min Max Min Max A/F (G) A/C (H)
472AA-51 472AA-51V 16 3.8 8.7 8.0 13.2 0.9 M16×1.5 15 41 23.4 26.7
472AA-71 472AA-71V 20SS 3.8 8.7 8.0 13.2 0.9 M20×1.5 15 41 23.4 26.7
472AA-52 472AA-52V 20S 8.0 11.8 8.0 15.8 0.9 /1.25 M20×1.5 15 43 25.7 29.2
472AA–53 472AA–53V 20 11.8 14.2 11.7 20.8 0.9 /1.25 M20×1.5 15 43 30.5 34.0
472AA–55 472AA–55V 25 14.0 20.1 17.0 27.2 1.25 / 1.6 M25×1.5 15 48 37.6 42.2
472AA–56 472AA–56V 32 19.7 26.6 23.5 33.5 1.6 / 2.0 M32×1.5 15 53 47.2 53.6
472AA–57 472AA–57V 40 26.6 32.4 29.0 39.9 1.6 / 2.0 M40×1.5 15 56 56.4 61.5
472AA-58 472AA-58V 50S 32.4 38.4 38.0 46.2 2.0 / 2.5 M50×1.5 15 61 60.0 66.0
472AA–59 472AA–59V 50 38.4 44.3 39.5 52.6 2.0 / 2.5 M50×1.5 15 61 70.1 77.2
472AA–60 472AA–60V 63S 44.3 50.3 50.0 58.9 2.5 M63×1.5 15 64 75.0 83.0
472AA–61 472AA–61V 63 50.3 56.2 51.3 65.3 2.5 M63×1.5 15 64 80.0 87.4
472AA–62 472AA–62V 75S 56.2 62.2 62.0 71.6 2.5 M75x1.5 15 73 90.2 99.1
472AA–63 472AA–63V 75 62.2 68.1 62.5 78.0 2.5 M75x1.5 15 73 98.8 109.2
472AA–64 472AA–64V 85 68.0 74.0 68.0 88.0 3.15 M85x1.5 20 102 115.1 126.0