Protolon Cable (N)TSCGEWOEU – Prysmian MV Medium Voltage Flexible Trailing Cables

Protolon Cable (N)TSCGEWOEU - Prysmian MV Medium Voltage Flexible Trailing Cables

Protolon Cable

Protolon Cable (N)TSCGEWOEU

Protolon cables type (N)TSCGEWOEU, are flexible and trailing medium voltage (MV) reeling cables.

Protolon (N)TSCGEWOEU cable is specified and installed for medium voltage flexible cable applications under high to extreme mechanical stresses, e.g. high travel speeds, dynamic tensile loads, multiple changes of direction into different planes, churning on running over rollers and torsional stresses.

MV Medium Voltage

Protolon Cable (N)TSCGEWOEU is available with the following ratings for medium voltage power supply:

  • 1.8/3kV
  • 3.6/6kV
  • 6/10kV
  • 8.7/15kV
  • 12/20kV

MV Medium Voltage Flexible Trailing Cables

âž¡ More Prysmian Cables MV HV Medium & High Voltage –  6.6kV 11kV 15kV 33kV Single & 3 Core

PROTOLON CABLE (N)TSCGEWOEU Specification

Conductor – Conductor and earth conductor made of electrolytic copper tinned, very finely stranded, class FS (refer also to DIN VDE 0295)

Insulation – Protolon HS high grade special compound based on high-quality EPR (at least 3GI3); improved mechanical and electrical characteristics (refer also to DIN VDE 0207, Part 20)

Electrical Field Control – Inner semiconductive layer of EPR, outer semiconductive layer of modified NBR, capable of being stripped when cold and thus extremely easy to prepare (Easy Strip design).

Core Identification – Natural coloured insulation with black semi-conductive layer

Core Arrangement – 3 core design, with earth conductor split into 3 parts positioned in the interstices

Cable Sheath System

  1. Protofirm Sandwich – double layer inner sheath. Compound based on EPR, quality at least 5GM3, served as water barrier, colour: red;
  2. Anti-torsion Braid – reinforced braid made of polyester threads, in a vulcanized bond between the sheaths, resulting in high strength of the sheath
  3. Protofirm Sandwich – double layer outer sheath: A sheath system with a unique combination of flexibility and robustness has been achieved through the use of a new sandwich structure. Abrasion and tear-proof high grade rubber compounds based on PCP, quality at least 5GM5, colour: bright red/red.

Cable Marking

Protolon (SMK) (N)TSCGEWOEU (number of cores)x(cross-section) (rated voltage) (year of manufacture) (serial number)

 

Protolon Cable Electrical Parameters

Rated Voltage 1.8/3kV 3.6/6kV 6/10kV 8.7/15kV 12/20kV
Maximum Permissible Operating Voltage AC 2.1/3.6kV 4.2/7.2kV 6.9/12kV 10.4/18kV 13.9/24kV
Maximum Permissible Operating Voltage DC 2.7/5.4kV 5.4/10.8kV 9/18kV 13.5/27kV 18/36kV
AC Test Voltage 6kV 11kV 17kV 24kV 29kV
EMC This design exhibits an extremely low interference level as a result of use of a symmetrical three-core design with very narrow manufacturing tolerances
Data Transmission Special designs with Twist Shielded Pairs or Individually Screened control elements available on request. A special cable design with fibre optics can be found in the product range Protolon (SMK)-LWL
Current Carrying Capacity Description According to DIN VDE 0298, Part 4. Higher values are permissible in specific cases (please consult the manufacturer)

 

Protolon Cable

Protolon Cables – MV Flexible Trailing Cables For Cranes & Port Authorities

Chemical Parameters

  • Oil Resistance – according to DIN EN 60811-404 and DIN VDE 0473-811-404, paragraph 10
  • Weather Resistance – unrestricted use outdoors and indoors, resistant to ozone, UV and moisture
  • Water Resistance – according to HD 2216

Thermal Parameters

  • Max. permissible temperature at conductor 90 °C
  • Max. short circuit temperature of the conductor 250 °C
  • Ambient temperature for fixed installation min -50 °C ; max +80 °C
  • Ambient temperature in fully flexible operation min -35 °C ; max +80 °C

Mechanical Parameters

  • Max. tensile load on the conductor 20 N/mm²
  • Max. tensile load on the conductor during acceleration Up to 30 (acc. to DIN VDE 0298 part 3: 15 N/mm²) N/mm²
  • Torsional stress ± 25 °/m
  • Min. bending radius Acc. to DIN VDE 0298 part 3
  • Min. distance with S-type directional changes 20 x D (D = cable diameter)
  • Travel speed – Gantry (reeling operation): no restriction. For speeds beyond 240 m/min it is recommended to consult T&D
  • Additional tests – reversed bending test, torsional stress test
Protolon Cables

Prysmian Cables | Terminations | Joints | Glands | Cleats | Protolon Cable MV HV

Data Sheets