Prysmian FP100 Fire Resistant Cable – BS6387 Single Core FP Cable (Conduit Trunking)
Fire Resistant Cable
Prysmian FP100
Prysmian FP100 is fire resistant single core cable for use in steel conduit or trunking when using BS5266-1:2005.
FP100 is specified for use when upgrading existing steel conduit systems to current specification and also for new build projects featuring metallic trunking – the fire resistant cable can be used for emergency lighting, fire detection and fire alarm circuits for systems that do not require twisted pairs or a built-in metallic screen.
Prysmian FP100 fire resistant cable is suitable for use as part of a ‘standard’ or ‘enhanced’ fire resistant cable system and can help solve the installation issues when surface or void installation is not an option.
Prysmian FP100 Fire Resistant Cable
features & Benefits
- Plain annealed copper stranded (class 2) conductor to meet the requirements of BS EN 60228 class 2
- Mineral ceramic (Mica/Glass) fire resistant tape. 90°C cross-linked insulation
- FP100 cable is available in brown, black, grey, blue, red, yellow, orange and green/yellow with other core colours on request
- Suitable for essential safety circuits where the cable is protected by metal conduit
- May be used for emergency lighting, fire alarm systems or other essential services
- Temperature range -25 to +90ºC
- Bending radius up to 8mm diameter r=40, above 9mm diameter r=60
- Mechanical impact requires protection
- Fire performance BS EN 60332-1-2
- Halogen free fire resistant cables – BS EN 60754-1
- Low smoke emissions – BS EN 61034-2
Prysmian FP100 Fire Resistant Cable
Performance Standards
- 450/750 V and 600/1000 V
- BS 6387:1994 Cat C (950±40°C for 180 mins)
- BS 6387:1994 Cat W (650±40°C for 30 mins)
- BS 6387:1994 Cat Z (950±40°C for 15 mins)
- EN 50267-2-2:1999
- EN 61034-2:2005
- IEC 60331-3:2009
- IEC 60331-21:1999
- Use in screwed steel conduit to achieve fire rating
- LPCB Approved
- Low smoke, zero halogen, flame retardant
Prysmian FP100 Fire Resistant Cable – Single Core Cables
Nominal Cross Sectional Area (sqmm) | Approximate Overall Diameter (mm) | Approximate Cable Weight (kg/km) | Maximum Conductor Resistance at 20ºC (Ω/km) | Short Circuit Rating (1 second) Amps | Current Rating DC or Single Phase AC (Amps) | Current Rating Three Phase DC (Amps) | Volt Drop DC (mV/A/m) | Volt Drop Single Phase AC (mV/A/m) | Volt Drop Three Phase AC (mV/A/m) |
1.5sqmm | 3.5 | 25 | 12.1 | 215 | 23 | 20 | 31 | 31 | 27 |
2.5sqmm | 4.2 | 37 | 7.41 | 360 | 31 | 28 | 19 | 19 | 16 |
4sqmm | 4.7 | 51 | 4.61 | 570 | 42 | 37 | 12 | 12 | 10 |
6sqmm | 5.3 | 79 | 3.08 | 860 | 54 | 48 | 7.9 | 7.9 | 6.8 |
10sqmm | 6.9 | 125 | 1.83 | 1425 | 75 | 66 | 4.7 | 4.7 | 4 |
16sqmm | 7.6 | 180 | 1.15 | 2275 | 100 | 88 | 2.9 | 2.9 | 2.5 |
25sqmm | 9.2 | 275 | 0.727 | 3375 | 133 | 117 | 1.85 | 1.9 | 1.65 |
35sqmm | 10.1 | 365 | 0.524 | 5000 | 164 | 144 | 1.35 | 1.35 | 1.15 |
50sqmm | 12.0 | 495 | 0.387 | 7150 | 198 | 175 | 0.99 | 1.05 | 0.9 |
70sqmm | 14.0 | 700 | 0.268 | 10000 | 253 | 222 | 0.68 | 0.75 | 0.65 |
95sqmm | 16.0 | 960 | 0.193 | 13575 | 306 | 269 | 0.49 | 0.58 | 0.5 |
120sqmm | 17.5 | 1190 | 0.153 | 17150 | 354 | 312 | 0.39 | 0.48 | 0.42 |
150sqmm | 20.0 | 1470 | 0.124 | 21450 | 393 | 342 | 0.32 | 0.43 | 0.37 |
185sqmm | 22.0 | 1830 | 0.0991 | 26450 | 449 | 384 | 0.25 | 0.37 | 0.32 |
240sqmm | 24.0 | 2400 | 0.0754 | 34325 | 528 | 450 | 0.19 | 0.33 | 0.29 |
300sqmm | 28.0 | 3050 | 0.0601 | 42925 | 603 | 514 | 0.155 | 0.31 | 0.27 |
400sqmm | 33.0 | 4000 | 0.0470 | 57225 | 683 | 584 | 0.120 | 0.29 | 0.25 |
500sqmm | 37.0 | 5100 | 0.0366 | 71525 | 783 | 666 | 0.093 | 0.28 | 0.24 |
630sqmm | 38.0 | 6150 | 0.0283 | 90125 | 900 | 764 | 0.072 | 0.27 | 0.23 |
- * Sizes 1.5 – 10sqmm are rated at 450/750V.
- Installation methods for current rating “Enclosed in conduit on a wall or in trunking” in accordance with BS7671/IEE Wiring Regulations. Table 4E1A
- Minimum recommended cable installation temperature -5°C.
- The tabulated ratings are based upon a 30°C ambient temperature at 90°C operating temperature.
- For other ambient temperatures or where several circuits are grouped together, appropriate rating factors should be applied.
FP100 Fire Resistant Cable – Temperature Ratings Factor
Ambient Temperature ºC | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 |
Rating Factor | 1.02 | 1.00 | 0.96 | 0.91 | 0.87 | 0.82 | 0.76 | 0.71 |
FP100 Fire Resistant Cable – Rating Factors For Groupings
Number of Circuits | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
Rating Factor | 0.80 | 0.70 | 0.65 | 0.60 | 0.57 | 0.54 | 0.52 | 0.50 |
FP Cable Accessories For Fire Resistant Cables
CABLE jOINTS ♦ CLEATS ♦ GLANDS
In order to protect the integrity of Prysmian FP fire resistant cables they should be installed in accordance with the manufacturers guidance including the use of fire resistant cable cleats, joints and glands.
View the complete range of Prysmian Cable Accessories for LV MV HV Cables, including 11kV-33kV networks or see product groups:
➡ For offshore cables, including BFOU and RFOU see Prysmian Draka.