3M 94-EB63-4
33kV Cable Termination Cold Shrink – 3M 94-EB63-4
3 Core Indoor Outdoor Cable Termination
These 3M QTII type cable terminations utilise Cold Shrink technology to terminate and connect MV HV cables – 3M 94-EB63-4 is a medium voltage cold shrink cable termination suitable for connecting 3 core polymeric (XLPE EPR) insulated cables up to 33kV with copper wire screened.
33kV Cable Terminations
3M QTII Cold Shrink Cable Termination Kits are designed for 33/36kV Umax voltage class, three core polymeric high voltage power cable systems according to HD 620 (IEC60502).
Cable termination suits 33kV cables with 25sqmm, 35sqmm, 50sqmm, 70sqmm, 95sqmm, 120sqmm, 150sqmm 3 core conductors.
Order Code – 3M 94-EB63-4
- Part Number – 3M 94-EB63-4
- 33kV Cable Termination (MV Medium Voltage)
- 19/33(36) kV Cables
- Cable Termination Type – Cold Shrink (Silicone)
- Manufacturer & Range – 3M QTII Termination
- Termination Indoor Outdoor (Substation, Switchgear, Transformer, Motor 33kV)
- Number Of Cores – 3 Core
- Conductors – 25-150sqmm
- Diameter Over Primary Insulation – 21.3 – 35.0mm
- Max. Lug Diameter Accepted (mm) – 35mm
- Includes integrated stress control device, silicone elastomeric insulation & silicone tape for moisture sealing
- Skirts are integrated for easier & faster installation
- Includes Scotchcast Resin for sealing the cable crutch
- Includes armour continuity components, re-jacketing tubes and three core cold shrink breakout boots
- Shelf Life – 3 years when stored between -40ºC to +50ºC
- Meets & exceeds European Standard CENELEC HD 629.1 and IEC 60502-4
- Single Core & Outdoor Pole-Mounted Terminations Available
- Also: 3M Cold Shrink Cable Joints MV HV
3M termination kits include sufficient components to terminate a 3 core cable, including breakout. Bushing boots optional.
3M QTII Series Terminations including 3M 94-EB63-4 are not subject of the European WEEE and RoHS Directives but meet their requirements.
PRODUCT IDENTIFICATION
3M QTII Series Cold Shrink Termination kits are marked with supplier name, cable cross section ranges (sqmm), voltage class and cable type, storage conditions and 3M manufacturing codes for product traceability.
TERMINATION PERFORMANCE TESTS
3M™ QTII 94-EB Series Cable Terminations, manufactured using Cold Shrink technology, meet and exceed the requirements of the European standard CENELEC HD 629.1 as well as IEC 60502-4.
Cold Shrink Storage
The shelf life of 3M 94-EB63-4 cold shrink terminations is specified as 3 years. Temperature: – 40°C to +50°C.
3M 33kV Cable Termination Part Number | Application Range Guide (sqmm) | Diameter Over Primary Insulation (mm) | Maximum Lug Diameter Accepted (mm) |
3M 94-EB63-4 | 25-150sqmm | 21.3–35.0mm | 35mm |
3M 94-EB64-4 | 95–240sqmm | 27.4–45.7mm | 45mm |
Watch Video ➡ 3M Cold Shrink Terminations – QTII Standard Terminations

3M QTII Cold Shrink Cable Terminations | MV HV | 3.3/6.6(7.2)kV 11kV 33kV 26/45(52)kV
Medium & high voltage cable glands, cleats & accessories
Complete ranges of cable cleats and cable glands are available to support the termination and installation of medium/high voltage power cables up to 33kV.
➡ See full range of 3M Cold Shrink Cable Terminations or visit only 33kV 3 Core Indoor Terminations.