Barrier Cable Glands Ex e, Ex d, Ex nR, Ex ta Armoured Cables – CMP PX2K

Barrier Cable Glands Ex e, Ex d, Ex nR, Ex ta Armoured Cables - CMP PX2K

CMP PX2K Barrier Cable Gland

CMP PX2K barrier cable gland for terminating all types of wire braid, tape, strip and single wire armoured type cables located in Zone 2 hazardous areas.

CMP PX2K Cable Glands

  • Metal-to-metal armour clamping
  • Direct & remote installation cable gland
  • Compound barrier type flameproof seal
  • Controlled outer ‘load retention’ seal
  • Unique OSTG prevents overtightening cable gland
  • Integral protected deluge seal
  • -60˚C to +85˚C
  • Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
  • Globally marked – hazardous area certified to IECEx, ATEX, UL & cCSAus
  • EMC tested
  • Order Code: CMP PX2K** (Brass) Cable Gland 

Hazardous Area Cable Glands

CMP PX2K barrier cable glands are certified by ATEX for safe glanding of cables in Zone 2 potentially explosive atmospheres according to the following hazardous area classification:

  • II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da
  • II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb

➡ See full range of CMP ATEX Barrier Cable Glands for armoured, braided and unarmoured cables – to view the complete range of CMP glands for Zone 1 & Zone 2 cable termination please visit Hazardous Area Cable Glands Zone 1 & Zone 2 locations.

cmp PX2K Barrier Cable Glands specification

CMP PX2K Barrier Cable Gland Material: Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel

Cable Gland Design Specification: BS6121: Part 1: 1989, IEC 62444, EN 62444

The following table enables the selection of CMP PX2K barrier cable glands – should you need to discuss a specific application for hazardous area or high voltage cable applications please call T&D.

CMP Cable Gland Size Available Entry Threads “C” (Alternative Metric Thread Lengths Available Number of Cores Diameter Over Conductors “A” Cable Bedding Diameter “G” Overall Cable Diameter “B” Armour Range Across Flats “D” Across Corners “D” Protrusion Length “F” Combined Ordering Reference (Brass Metric) Cable Gland Shroud Cable Gland Weight (kgs)
Standard Option Grooved Cone (X) Stepped Cone (W)
Metric Thread Length (Metric) “E” NPT Thread Length (NPT) “E” NPT Max Max Max Min Max Min Max Min Max Max Max Max Size Type Ordering Suffix
PX2K20s16 M20 15.0 1/2″ 19.9 3/4″ 11 11.7 11.7 6.1 13.1 0.3 1.0 0.8 1.25 30.5 33.6 62.0 20S16 PX2K 1RA PVC06 0.24
PX2K20S M20 15.0 1/2″ 19.9 3/4″ 11 11.7 11.7 9.5 15.9 0.3 1.0 0.8 1.25 30.5 33.6 62.0 20S PX2K 1RA PVC06 0.23
PX2K20 M20 15.0 1/2″ 19.9 3/4″ 11 12.6 12.9 12.5 20.9 0.4 1.0 0.8 1.25 30.5 33.6 63.0 20 PX2K 1RA PVC06 0.24
PX2K25S M25 15.0 3/4″ 20.2 1″ 21 17.5 17.9 14.0 22.0 0.4 1.2 1.25 1.6 37.5 41.3 69.5 25S PX2K 1RA PVC09 0.37
PX2K25 M25 15.0 3/4″ 20.2 1″ 21 17.5 17.9 18.2 26.2 0.4 1.2 1.25 1.6 37.5 41.3 69.5 25 PX2K 1RA PVC09 0.37
PX2K32 M32 15.0 1″ 25.0 1 1/4″ 38 23.6 23.9 23.7 33.9 0.4 1.2 1.6 2.0 46.0 50.5 75.0 32 PX2K 1RA PVC11 0.57
PX2K40 M40 15.0 1 1/4″ 25.6 1 1/2″ 59 30.0 30.3 27.3 40.4 0.4 1.6 1.6 2.0 55.0 60.5 75.0 40 PX2K 1RA PVC15 0.80
PX2K50S M50 15.0 1 1/2″ 26.1 2″ 89 36.6 36.9 35.2 46.7 0.4 1.6 2.0 2.5 60.0 66.0 77.0 50S PX2K 1RA PVC18 0.90
PX2K50 M50 15.0 2″ 26.9 2 1/2″ 89 41.0 41.3 40.4 53.0 0.6 1.6 2.0 2.5 70.1 77.1 77.0 50 PX2K 1RA PVC21 1.19
PX2K63S M63 15.0 2″ 26.9 2 1/2″ 115 47.9 48.4 45.6 59.4 0.6 1.6 2.0 2.5 75.0 82.5 79.7 63S PX2K 1RA PVC23 1.39
PX2K63 M63 15.0 2 1/2″ 39.9 3″ 115 53.7 54.0 54.6 65.8 0.6 1.6 2.0 2.5 80.0 88.0 80.3 63 PX2K 1RA PVC25 1.41
PX2K75S M75 15.0 2 1/2″ 39.9 3″ 140 59.9 60.2 59.0 72.0 0.6 1.6 2.0 2.5 90.0 99.0 86.8 75S PX2K 1RA PVC28 2.09
PX2K75 M75 15.0 3″ 41.5 3 1/2″ 140 64.2 64.2 66.7 78.4 0.6 1.6 2.5 3.0 100.0 110.0 88.3 75 PX2K 1RA PVC30 2.54
PX2K90 M90 24.0 3 1/2″ 42.8 4″ 200 75.3 75.6 76.2 90.3 0.8 1.6 3.15 4.0 115.0 126.5 102.1 90 PX2K 1RA PVC32 3.71
PX2K100 M100 24.0 3 1/2″ 42.8 4″ 200 85.6 85.9 86.1 101.4 0.8 1.6 3.15 4.0 127.0 139.7 114.0 100 PX2K 1RA LSF33 4.31

CMP PX2K Barrier Cable Gland

Barrier Cable Glands Ex e, Ex d, Ex nR, Ex ta Armoured Cables - CMP PX2K

PX2K Cable Glands CMP

CMP Cable Glands

CMP Cable Glands – cable terminations for Industrial, High Voltage, Hazardous Area Explosive Atmospheres (ATEX & IECEx) & Group 1 Mining Cables  – including CIEL High Fault Current, SOLO Low Smoke Zero Halogen, ZEN Insulated & RapidEx Barrier Cable glands

➡ For connecting, repairing or splicing cables see Hazardous Area Cable Joints.

Data Sheets