Barrier Cable Glands For Unarmoured & Braided Cables In Hazardous Areas – CMP PXSS2K

Barrier Cable Glands For Unarmoured & Braided Cables In Hazardous Areas - CMP PXSS2K

CMP PXSS2K Barrier Cable Gland

CMP PXSS2K barrier cable gland for terminating all types of unarmoured & braid armour type cables located in Zone 2 hazardous areas.

CMP PXSS2K Cable Glands

  • Direct & remote installation cable gland
  • Superior levels of cable retention
  • Displacement type environmental seal
  • Compound barrier type flameproof seal
  • Designed to prevent Coldflow
  • Integral protected deluge seal
  • -60˚C to +85˚C
  • Class I Zone 1, 21 and Zone 2, 22
  • Globally marked – hazardous area certified to IECEx, ATEX, UL & cCSAus
  • EMC tested
  • Order Code: CMP PXSS2K** (Brass) Cable Gland 

Hazardous Area Cable Glands

CMP PXSS2K barrier cable glands are certified by ATEX for safe glanding of cables in Zone 2 potentially explosive atmospheres according to the following hazardous area classification:

  • II 2 GD, II 1D, Ex d IIC Gb, Ex e IIc Gb, Ex ta IIIC Da
  • II 3 G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb

➡ See full range of CMP ATEX Barrier Cable Glands for armoured, braided and unarmoured cables – to view the complete range of CMP glands for Zone 1 & Zone 2 cable termination please visit Hazardous Area Cable Glands Zone 1 & Zone 2 locations.

cmp PXSS2K Barrier Cable Glands specification

CMP PXSS2K Barrier Cable Gland Material: Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel

Cable Gland Design Specification: BS6121: Part 1: 1989, IEC 62444, EN 62444

The following table enables the selection of CMP PXSS2K barrier cable glands – should you need to discuss a specific application for hazardous area or high voltage cable applications please call T&D.

CMP Cable Gland Size Available Entry Threads “C” (Alternative Metric Thread Lengths Available Number of Cores Diameter Over Conductors “A” Cable Bedding Diameter “G” Overall Cable Diameter “B” Across Flats “D” Across Corners “D” Protrusion Length “F” Combined Ordering Reference (Brass Metric) Cable Gland Shroud Cable Gland Weight (kgs)
Standard Option
Metric Thread Length (Metric) “E” NPT Thread Length (NPT) “E” NPT Max Max Max Min Max Max Max Max Size Type Ordering Suffix
PXSS2K20s16 M20 15.0 1/2″ 19.9 3/4″ 11 8.6 8.6 3.1 8.6 30.0 33.0 53.1 20S16 PXSS2K 1RA PVC06 0.20
PXSS2K20S M20 15.0 1/2″ 19.9 3/4″ 11 11.7 11.7 6.1 11.7 30.0 33.0 53.1 20S PXSS2K 1RA PVC06 0.20
PXSS2K20 M20 15.0 1/2″ 19.9 3/4″ 11 12.6 12.9 6.5 14.0 30.0 33.0 54.2 20 PXSS2K 1RA PVC06 0.20
PXSS2K25 M25 15.0 3/4″ 20.2 1″ 21 17.5 17.9 11.1 20.0 36.0 39.6 60.0 25 PXSS2K 1RA PVC09 0.33
PXSS2K32 M32 15.0 1″ 25.0 1 1/4″ 38 23.6 23.9 17.0 26.3 41.0 45.1 61.1 32 PXSS2K 1RA PVC10 0.39
PXSS2K40 M40 15.0 1 1/4″ 25.6 1 1/2″ 59 30.0 30.3 22.0 32.1 50.0 55.0 62.4 40 PXSS2K 1RA PVC13 0.56
PXSS2K50S M50 15.0 1 1/2″ 26.1 2″ 89 36.6 36.9 29.5 38.2 55.0 60.5 65.2 50S PXSS2K 1RA PVC15 0.66
PXSS2K50 M50 15.0 2″ 26.9 2 1/2″ 89 41.0 41.3 35.6 44.0 60.0 66.0 67.6 50 PXSS2K 1RA PVC18 0.73
PXSS2K63S M63 15.0 2″ 26.9 2 1/2″ 115 47.9 48.4 40.1 49.9 70.1 77.1 71.1 63S PXSS2K 1RA PVC21 1.07
PXSS2K63 M63 15.0 2 1/2″ 39.9 3″ 115 53.7 54.0 47.2 55.9 75.0 82.5 70.4 63 PXSS2K 1RA PVC23 1.06
PXSS2K75S M75 15.0 2 1/2″ 39.9 3″ 140 59.9 60.2 52.8 61.9 80.0 88.0 75.3 75S PXSS2K 1RA PVC25 1.30
PXSS2K75 M75 15.0 3″ 41.5 3 1/2″ 140 64.2 64.2 59.1 67.9 85.0 93.5 74.9 75 PXSS2K 1RA PVC27 1.30
PXSS2K90 M90 24.0 3 1/2″ 42.8 4″ 200 75.3 75.6 66.6 79.4 108.0 118.8 94.8 90 PXSS2K 1RA PVC31 3.02
PXSS2K100 M100 24.0 3 1/2″ 42.8 4″ 200 85.6 85.9 76.0 90.9 123.0 135.3 86.3 100 PXSS2K 1RA LSF33 4.00

CMP PXSS2K Barrier Cable Gland

Barrier Cable Glands For Unarmoured & Braided Cables In Hazardous Areas - CMP PXSS2K

PXSS2K Cable Glands CMP

CMP Cable Glands

CMP Cable Glands – cable terminations for Industrial, High Voltage, Hazardous Area Explosive Atmospheres (ATEX & IECEx) & Group 1 Mining Cables  – including CIEL High Fault Current, SOLO Low Smoke Zero Halogen, ZEN Insulated & RapidEx Barrier Cable glands

➡ For connecting, repairing or splicing cables see Hazardous Area Cable Joints.