Barrier Cable Glands For Lead Sheathed Armoured Cables In Hazardous Areas – CMP PX2KPB

Barrier Cable Glands For Lead Sheathed Armoured Cables In Hazardous Areas - CMP PX2KPB

CMP PX2KPB Barrier Cable Gland

CMP PX2KPB barrier cable gland for terminating all types of lead sheathed armoured type cables located in Zone 2 hazardous areas.

CMP PX2KPB Cable Glands

  • Effectively earths / grounds lead sheathed cables
  • Metal-to-metal armour clamping
  • Direct & remote installation cable gland
  • Compound barrier type flameproof seal
  • Controlled outer ‘load retention’ seal
  • Unique OSTG prevents overtightening cable gland
  • Integral protected deluge seal
  • -60˚C to +85˚C
  • Globally marked – hazardous area certified to IECEx & ATEX
  • EMC tested
  • Order Code: CMP PX2KPB** (Brass) Cable Gland 

Hazardous Area Cable Glands

CMP PX2KPB barrier cable glands are certified by ATEX for safe glanding of cables in Zone 2 potentially explosive atmospheres according to the following hazardous area classification:

  • II 2G, II 1D, Ex d IIC Gb, Ex e IIC Gb, Ex ta IIIC Da,
  • II 3G Ex nR IIC Gc, IM2 Ex d I Mb, Ex e I Mb

➡ See full range of CMP ATEX Barrier Cable Glands for armoured, braided and unarmoured cables – to view the complete range of CMP glands for Zone 1 & Zone 2 cable termination please visit Hazardous Area Cable Glands Zone 1 & Zone 2 locations.

cmp PX2KPB Barrier Cable Glands specification

CMP PX2KPB Barrier Cable Gland Material: Brass, Electroless Nickel Plated Brass, Aluminium, Stainless Steel

Cable Gland Design Specification: BS6121: Part 1: 1989, IEC 62444, EN 62444

The following table enables the selection of CMP PX2KPB barrier cable glands – should you need to discuss a specific application for hazardous area or high voltage cable applications please call T&D.

CMP Cable Gland Size Available Entry Threads “C” (Alternative Metric Thread Lengths Available Number of Cores Diameter Over Conductors “A” Lead Sheath Diameter “G” Overall Cable Diameter “B” Armour Range Across Flats “D” Across Corners “D” Protrusion Length “F” Combined Ordering Reference (Brass Metric) Cable Gland Shroud Cable Gland Weight (kgs)
Standard Option Grooved Cone (X) Stepped Cone (W)
Metric Thread Length (Metric) “E” NPT Thread Length (NPT) “E” NPT Max Max Min Max Min Max Min Max Min Max Max Max Max Size Type Ordering Suffix
PX2KPB20s16 M20 15.0 1/2″ 19.9 3/4″ 11 11.7 3.1 7.8 6.1 13.1 0.3 1.0 0.8 1.25 30.5 33.6 62.0 20S16 PX2KPB 1RA PVC06 0.25
PX2KPB20S M20 15.0 1/2″ 19.9 3/4″ 11 11.7 6.1 11.0 9.5 15.9 0.3 1.0 0.8 1.25 30.5 33.6 62.0 20S PX2KPB 1RA PVC06 0.23
PX2KPB20 M20 15.0 1/2″ 19.9 3/4″ 11 12.6 6.5 13.4 12.5 20.9 0.4 1.0 0.8 1.25 30.5 33.6 63.0 20 PX2KPB 1RA PVC06 0.24
PX2KPB25S M25 15.0 3/4″ 20.2 1″ 21 17.5 11.1 19.3 14.0 22.0 0.4 1.2 1.25 1.6 37.5 41.3 69.5 25S PX2KPB 1RA PVC09 0.37
PX2KPB25 M25 15.0 3/4″ 20.2 1″ 21 17.5 11.1 19.3 18.2 26.2 0.4 1.2 1.25 1.6 37.5 41.3 69.5 25 PX2KPB 1RA PVC09 0.37
PX2KPB32 M32 15.0 1″ 25.0 1 1/4″ 38 23.6 17.0 25.5 23.7 33.9 0.4 1.2 1.6 2.0 46.0 50.5 75.0 32 PX2KPB 1RA PVC11 0.57
PX2KPB40 M40 15.0 1 1/4″ 25.6 1 1/2″ 59 30.0 22.0 31.2 27.3 40.4 0.4 1.6 1.6 2.0 55.0 60.5 75.0 40 PX2KPB 1RA PVC15 0.80
PX2KPB50S M50 15.0 1 1/2″ 26.1 2″ 89 36.6 29.5 37.2 35.2 46.7 0.4 1.6 2.0 2.5 60.0 66.0 77.0 50S PX2KPB 1RA PVC18 0.90
PX2KPB50 M50 15.0 2″ 26.9 2 1/2″ 89 41.0 35.6 42.6 40.4 53.0 0.6 1.6 2.0 2.5 70.1 77.1 77.0 50 PX2KPB 1RA PVC21 1.19
PX2KPB63S M63 15.0 2″ 26.9 2 1/2″ 115 47.9 40.1 48.5 45.6 59.4 0.6 1.6 2.0 2.5 75.0 82.5 79.7 63S PX2KPB 1RA PVC23 1.41
PX2KPB63 M63 15.0 2 1/2″ 39.9 3″ 115 53.7 47.2 54.2 54.6 65.8 0.6 1.6 2.0 2.5 80.0 88.0 80.3 63 PX2KPB 1RA PVC25 1.44
PX2KPB75S M75 15.0 2 1/2″ 39.9 3″ 140 59.9 52.8 60.2 59.0 72.0 0.6 1.6 2.0 2.5 90.0 99.0 86.8 75S PX2KPB 1RA PVC28 2.13
PX2KPB75 M75 15.0 3″ 41.5 3 1/2″ 140 64.2 59.1 65.2 66.7 78.4 0.6 1.6 2.5 3.0 100.0 110.0 88.3 75 PX2KPB 1RA PVC30 2.57
PX2KPB90 M90 24.0 3 1/2″ 42.8 4″ 200 75.3 66.6 77.1 76.2 90.3 0.8 1.6 3.15 4.0 115.0 126.5 102.1 90 PX2KPB 1RA PVC32 3.75
PX2KPB100 M100 24.0 3 1/2″ 42.8 4″ 200 85.6 76.0 88.1 86.1 101.4 0.8 1.6 3.15 4.0 127.0 139.7 114.0 100 PX2KPB 1RA LSF33 4.87

CMP PX2KPB Barrier Cable Gland

Barrier Cable Glands For Lead Sheathed Armoured Cables In Hazardous Areas - CMP PX2KPB

PX2KPB Cable Glands CMP

CMP Cable Glands

CMP Cable Glands – cable terminations for Industrial, High Voltage, Hazardous Area Explosive Atmospheres (ATEX & IECEx) & Group 1 Mining Cables  – including CIEL High Fault Current, SOLO Low Smoke Zero Halogen, ZEN Insulated & RapidEx Barrier Cable glands

➡ For connecting, repairing or splicing cables see Hazardous Area Cable Joints.