IECEx ATEX Hazardous Area Cable Glands – Prysmian A2EX 494NE Series Glands

IECEx ATEX Hazardous Area Cable Glands – Prysmian A2EX 494NE Series Glands
Prysmian A2EXP 494NE are ATEX & IECEX certified cable glands for hazardous areas providing high performance in both deluge and IP68 conditions. The dual seal cable glands are IECEX and ATEX rated Ex d IIC / Ex e II.
Prysmian A2EXP brass cable glands are suitable for terminating circular unarmoured cables with extruded oversheath for use indoors or outdoors – use to connect, terminate or gland cable into flameproof or increased safety equipment in hazardous areas.
PRYSMIAN A2EXP 494NE CABLE GLANDS
FEATURES & BENEFITS
- Brass indoor and outdoor cable gland for use in hazardous areas
- Suitable for circular unarmoured cables with extruded oversheath
- Fitted with silicone rubber low smoke, zero halogen seal
- Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant
- Suitable for most climatic conditions – weatherproof, waterproof and deluge proof
- Standard and Nickel plated versions available
- Full Installation Instructions supplied
ATEX CERTIFIED CABLE GLANDS
HAZARDOUS AREA CLASSIFICATIONS
Certified II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC.
Prysmian cable glands type A2EXP 494NE are suitable for terminating unarmoured cables in the following hazardous area locations:
- Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
- Zones 1 & 2 with Ex ib IIA, B & C Equipment
- Zones 1 & 2 with Ex e II Equipment
- Zones 1 & 2 with Ex p II Equipment
- Zone 2 with Ex nA II Equipment
- Zone 21 & 22 with Ex tD II Equipment
♦ For jointing cables in Zone 1 / Zone 2 hazardous areas see the 3M Electrical range of Scotchcast 1402FR (LV) and Cold Shrink (MV HV) cable joints.
PRYSMIAN A2EXP 494NE GLANDS
PRODUCT SPECIFICATION
Prysmian Cable Gland Ordering Reference | Cable Dimensions mm | Cable Gland Dimensions mm | |||||||
Design Reference | Size | Cable Diameter Ø (B) mm E | Entry Thread (D) | Thread Length (E) | Protrusion Length (F) | Hexagon | |||
Standard | Nickel Plated | A/F (G) | A/C (H) | ||||||
Min | Max | ||||||||
494NE-03 | 494NE-03V | 1/2”- 16 | 3.5 | 8.5 | 1/2” NPT | 15.5 | 36 | 25.7 | 28.7 |
494NE-04 | 494NE-04V | 1/2”- 20S | 8.0 | 11.5 | 1/2” NPT | 15.5 | 36 | 27.8 | 31.8 |
494NE-05 | 494NE-05V | 1/2”- 20 | 8.0 | 16.0 | 1/2” NPT | 15.5 | 34 | 33 | 36.9 |
494NE-08 | 494NE-08V | 3/4” – 20 | 8.0 | 16.0 | 3/4” NPT | 16.4 | 34 | 33 | 36.9 |
494NE-10 | 494NE-10V | 3/4” – 25 | 11.5 | 21.0 | 3/4” NPT | 16.4 | 44 | 33 | 36.9 |
494NE-14 | 494NE-14V | 1” – 25 | 11.5 | 21.0 | 1” NPT | 19.5 | 44 | 37.5 | 42.2 |
494NE-15 | 494NE-15V | 1” – 32 | 18.5 | 27.5 | 1” NPT | 19.5 | 38 | 37.5 | 42.2 |
494NE-20 | 494NE-20V | 11/4” – 32 | 18.5 | 27.5 | 11/4” NPT | 20.5 | 38 | 47.2 | 52.9 |
494NE-21 | 494NE-21V | 11/4” – 40 | 24.0 | 34.0 | 11/4” NPT | 20.5 | 46 | 47.2 | 53.6 |
494NE-27 | 494NE-27V | 1 1/2” – 40 | 24.0 | 34.0 | 11/2” NPT | 21 | 46 | 56.4 | 63.1 |
494NE-32 | 494NE-32V | 2” – 50 | 31.0 | 41.0 | 2” NPT | 22 | 44 | 65 | 71.5 |
494NE-38 | 494NE-38V | 21/2” – 63 | 40.0 | 52.5 | 21/2” NPT | 32.5 | 61 | 80 | 87.4 |
494NE-44 | 494NE-44V | 3” – 75S | 52.5 | 58.0 | 3” NPT | 33.5 | 46 | 98.8 | 109.2 |
494NE-45 | 494NE-45V | 3”- 75 | 54.5 | 65.5 | 3” NPT | 33.5 | 66 | 98.8 | 109.2 |

Prysmian A2EXP 495NE Series Glands – Dimensions
Cable Glands
See the complete range of Cable Glands for wire armoured (SWA / AWA), braided (tinned copper / phosphor bronze), unarmoured and lead sheathed cables.
Hazardous Area (ATEX IECEx) | Explosion Proof |
Medium & High Voltage MV HV | Low Smoke Zero Halogen |
Fire Resistant (FP) | Mining Cables (Group 1) |
High Fault Current | Industrial Cables LV HV 11kV 33kV |

View the complete range of BICON Cable Glands for Industrial, Hazardous Areas & High Voltages