IECEx ATEX Hazardous Area Cable Glands – Prysmian A2EX 494NE Series Glands

IECEx ATEX Hazardous Area Cable Glands - Prysmian A2EX 494NE Series Glands

IECEx ATEX Hazardous Area Cable Glands – Prysmian A2EX 494NE Series Glands

Prysmian A2EXP 494NE are ATEX & IECEX certified cable glands for hazardous areas providing high performance in both deluge and IP68 conditions. The dual seal cable glands are IECEX and ATEX rated Ex d IIC / Ex e II.

Prysmian  A2EXP brass cable glands are suitable for terminating circular unarmoured cables with extruded oversheath for use indoors or outdoors – use to connect, terminate or gland cable into flameproof or increased safety equipment in hazardous areas.

PRYSMIAN A2EXP 494NE CABLE GLANDS

FEATURES & BENEFITS

  • Brass indoor and outdoor cable gland for use in hazardous areas
  • Suitable for circular unarmoured cables with extruded oversheath
  • Fitted with silicone rubber low smoke, zero halogen seal
  • Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant
  • Suitable for most climatic conditions – weatherproof, waterproof and deluge proof
  • Standard and Nickel plated versions available
  • Full Installation Instructions supplied

ATEX CERTIFIED CABLE GLANDSIEC & ATEX Cable Glands For Hazardous Areas

HAZARDOUS AREA CLASSIFICATIONS

Certified II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC.

Prysmian cable glands type A2EXP 494NE are suitable for terminating unarmoured cables in the following hazardous area locations:

  • Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
  • Zones 1 & 2 with Ex ib IIA, B & C Equipment
  • Zones 1 & 2 with Ex e II Equipment
  • Zones 1 & 2 with Ex p II Equipment
  • Zone 2 with Ex nA II Equipment
  • Zone 21 & 22 with Ex tD II Equipment

♦ For jointing cables in Zone 1 / Zone 2 hazardous areas see the 3M Electrical range of Scotchcast 1402FR (LV) and Cold Shrink (MV HV) cable joints.

Hazardous Cable Glands Prysmian

PRYSMIAN A2EXP 494NE GLANDS

PRODUCT SPECIFICATION

Prysmian Cable Gland Ordering Reference Cable Dimensions mm Cable Gland Dimensions mm
Design Reference Size Cable Diameter Ø (B) mm E Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon
Standard Nickel Plated A/F (G) A/C (H)
Min Max
494NE-03 494NE-03V 1/2”- 16 3.5 8.5 1/2” NPT 15.5 36 25.7 28.7
494NE-04 494NE-04V 1/2”- 20S 8.0 11.5 1/2” NPT 15.5 36 27.8 31.8
494NE-05 494NE-05V 1/2”- 20 8.0 16.0 1/2” NPT 15.5 34 33 36.9
494NE-08 494NE-08V 3/4” – 20 8.0 16.0 3/4” NPT 16.4 34 33 36.9
494NE-10 494NE-10V 3/4” – 25 11.5 21.0 3/4” NPT 16.4 44 33 36.9
494NE-14 494NE-14V 1” – 25 11.5 21.0 1” NPT 19.5 44 37.5 42.2
494NE-15 494NE-15V 1” – 32 18.5 27.5 1” NPT 19.5 38 37.5 42.2
494NE-20 494NE-20V 11/4” – 32 18.5 27.5 11/4” NPT 20.5 38 47.2 52.9
494NE-21 494NE-21V 11/4” – 40 24.0 34.0 11/4” NPT 20.5 46 47.2 53.6
494NE-27 494NE-27V 1 1/2” – 40 24.0 34.0 11/2” NPT 21 46 56.4 63.1
494NE-32 494NE-32V 2” – 50 31.0 41.0 2” NPT 22 44 65 71.5
494NE-38 494NE-38V 21/2” – 63 40.0 52.5 21/2” NPT 32.5 61 80 87.4
494NE-44 494NE-44V 3” – 75S 52.5 58.0 3” NPT 33.5 46 98.8 109.2
494NE-45 494NE-45V 3”- 75 54.5 65.5 3” NPT 33.5 66 98.8 109.2
Prysmian A2EXP 495NE Series Glands - Dimensions

Prysmian A2EXP 495NE Series Glands – Dimensions

Cable Glands

See the complete range of Cable Glands for wire armoured (SWA / AWA), braided (tinned copper / phosphor bronze), unarmoured and lead sheathed cables.

Applications
Hazardous Area (ATEX IECEx) Explosion Proof
Medium & High Voltage MV HV Low Smoke Zero Halogen
Fire Resistant (FP) Mining Cables (Group 1)
High Fault Current Industrial Cables LV HV 11kV 33kV

 

Prysmian Cables Glands - BW CW A2 Brass Aluminium Glands

View the complete range of BICON Cable Glands for Industrial, Hazardous Areas & High Voltages