ABB POLIM-R..ND MV HV Surge Arrester Class DC-B DC Traction Systems 0.75kV Indoor & Outdoor

ABB POLIM-R..ND MV HV Surge Arrester Class DC-B DC Traction Systems 0.75kV Indoor & Outdoor

ABB POLIM-R..ND MV HV Surge Arrester Class DC-B DC Traction Systems 0.75kV Indoor & Outdoor

ABB POLIM-R..ND surge arresters are used for the short-circuit protection of medium voltage and high voltage electrical equipment and cables against overvoltages caused by lightning, atmospheric discharges and switching conditions up to 0.75kV.

POLIM-R..ND surge arrester is intended for use indoors and outdoors and are designed with metal-oxide (MO) resistors without spark gaps molded in silicone housing and tested according to IEC 62848-1 and EN 50526-1.

  • IEC 62848-1:2016 Railway applications – DC surge arresters and voltage limiting devices – Part 1: Metal-oxide surge arresters without gaps
  • EN 50526-1 Railway applications – Fixed installations – D.C. surge arresters and voltage limiting devices – Part 1: Surge arresters

ABB POLIM-R..ND surge arresters are for use with MV-HV cables, rolling stock, traction systems, fixed installations and secondary equipment – T&D distribute cable joints, terminations and connectors to support the construction of electrical networks, substations and overhead lines for 11kV, 33kV and up to 66kV.

Surge arresters should be installed as close as possible to the medium/high voltage electrical equipment to be protected within the protective distance with sheds pointing downwards – minimum permissible distances between the surge arresters and the earth must be observed.

ABB POLIM-R..ND MV HV Surge Arrester

Technical Specification

Part Number POLIM-R..1ND POLIM-R..2ND
Nominal Discharge Current /n 8/20μs 10kA Peak 20kA Peak
Line Discharge Class (LD) DC-B DC-B
High Current Operating Duty Test /hc 4/10μs 100kA Peak 100kA Peak
Switching Current Impulse / sw (30/60μs) 1000A Peak 2000A Peak
Charge Transfer Capability Qt 2.5 As 5 As
Energy Withstand Capability W 9.5kJ/kV Uc 19kj/kV Uc
Short Circuit Rating /s DC 20kA DC for 0.2s 20kA DC for 0.2s
Torque 20Nm 20Nm
Short Term Load SSL Perpendicular To Axis 60Nm 60Nm
Long Term Load SLL Perpendicular To Axis 30Nm 30Nm
Ambient Air Temperature -60 to +40ºC -60 to +40ºC
Altitude Up to 1800m Up to 1800m

 

ABB POLIM-R..1ND MV HV Surge Arrester Class DC-B DC Traction Systems 0.75kV Indoor & Outdoor - Dimensions

ABB POLIM-R..ND MV HV Surge Arrester – Dimensions

ABB Surge Arresters Overview

Should you require assistance for the specification or supply of MV-HV surge arresters for 11kV, 33kV and up to 52kV voltages please do not hesitate to contact us.

Surge Arrester Type

ABB Surge Arrester POLIM-D

POLIM-D

ABB Surge Arrester POLIM-D..PI-2 PI-3

POLIM-D..PI-2 PI-3

ABB Surge Arrester POLIM-K

POLIM-K

ABB Surge Arrester MWD

MWD

ABB Surge Arrester MWK

MWK

POLIM-C..N

POLIM-C..N

POLIM-C..LB

POLIM-C..LB

POLIM-I..N

POLIM-I..N

POLIM-S..N

POLIM-S..N

POLIM-R..N

POLIM-R..N

POLIM-H..N

POLIM-H..N

Technical Data
System Voltage Us ≤ 52kV ≤ 52kV ≤ 52kV ≤ 52kV ≤ 52kV ≤ 7.5kV ≤ 5kV ≤ 72kV ≤ 72kV ≤ 1kV ≤ 72kV
Continuous Operating Voltage Uc ≤ 44kV ≤ 42kV ≤ 44kV ≤ 44kV ≤ 44kV  ≤ 7.5kV ≤ 4.8kV ≤ 56kV ≤ 56kV ≤ 1kV ≤ 58kV
Nominal Discharge Current ln 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 20kA 20kA
High Current Impulse 100kA 65kA 100kA 100kA 100kA 100kA 100kA 100kA 100kA 100kA 100kA
IEC Line Discharge Class 1 1 2 2 2  2 2 2 3 4 4
Application Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor Indoor Indoor & Outdoor Indoor & Outdoor Indoor Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor
Medium Voltage & High Voltage Applications – Recommended Overvoltage Protection 11kV 33kV 52kV
Transformers Yes Yes Yes Yes Yes  Yes  – Yes Yes Yes
Overhead Lines Yes Yes Yes Yes Yes Yes
Cables Yes Yes Yes Yes Yes Yes
Rotating Machines Yes Yes Yes Yes Yes Yes
Capacitors & Capacitor Banks Yes Yes Yes Yes Yes Yes Yes
Cable Sheath Protection HV Cables Yes Yes Yes Yes Yes
Switchgear & Switching Cubicles Yes
Metal-Encapsulated Switchgear Yes
Inductances, Reactors, PLC Line Traps Yes
Transformers Of Arc Furnace Yes Yes
Further Medium Voltage Apparatuses Yes Yes Yes Yes Yes Yes Yes  Yes Yes
Component of Secondary Equipment  Yes Yes
Power Electronics Yes Yes

Surge Arrester Medium High Voltage MV HV 11kV 33kV 66kV

ABB Medium & High Voltage Products – complete range of MV-HV surge arresters for overvoltage protection of substations and overhead line distribution networks

Earthing Surge Arresters

Installers must observe national regulations and the requirements of the system owner/utility. ABB POLIM-R..ND surge arresters should be connected to the system ground via the shortest path – all contact surfaces should be cleaned and lubricated with acid-free contact grease.

Observe recommended minimum diameters for ABB POLIM-R..ND arresters:

  • Copper Diameter 20mm
  • Aluminium Diameter 40mm

Commissioning MV-HV Medium & High Voltage Surge Arresters

Due to the risk of electric shock only authorised personnel should work on ABB POLIM-R..ND surge arresters and observe BS EN 50110-1:2013 Operation of Electrical Installations – the MV-HV power system should be disconnected from the power supply, de-energised and grounded using portable short-circuit earthing kits for either substation or overhead line applications. If live-working is required and unavoidable around electrical equipment a calculation of arc risk should be sanctioned and appropriate arc flash protection clothing worn.

Arc Flash Clothing Protection PPE

Arc Flash Clothing | Protection For Workers on LV 11kV 33kV 52kV Electricity Substations, Switchgear, Cables & Lines

 