Celebrating Charlie & Ella’s Level 4 Sales Executive Apprenticeships
At Thorne & Derrick International, we are proud to champion talent development and recognise the dedication required to achieve professional growth.
We are therefore delighted to congratulate Charlie Baines and Ella Bradley, who have both successfully completed their Level 4 Sales Executive Apprenticeships through Gateshead Learning and Skills.
This is a significant achievement and reflects the determination, hard work and commitment Charlie and Ella have demonstrated throughout their apprenticeship journeys.
Their success also reflects Thorne & Derrick’s continued commitment to investing in its people and supporting apprenticeship programmes that create meaningful opportunities for professional development and long-term career progression.
A Thorne & Derrick First for Ella Bradley
We are especially proud to announce that Ella completed her apprenticeship with a distinction.
Ella is the first person at Thorne & Derrick to achieve a distinction in the Sales Executive apprenticeship, making this an important milestone for both Ella and the company.
This outstanding result reflects the consistently high standard of work Ella maintained throughout the programme, as well as her commitment to developing her knowledge, confidence and professional sales capabilities.
Ella’s distinction sets an inspiring example for other apprentices and colleagues working towards their own professional development goals.
A Testament to Dedication and Development
Completing a Level 4 apprenticeship requires apprentices to balance their everyday responsibilities with structured learning, workplace development and formal assessment.
Throughout the programme, Charlie and Ella continued to develop the knowledge, skills and professional behaviours required within a modern sales role.
Key Areas of Development Included:
Sales Planning – Developing structured and effective approaches to sales activity.
Customer Engagement – Building trusted relationships and communicating confidently with customers.
Product and Sector Knowledge – Strengthening their understanding of Thorne & Derrick’s specialist products and markets.
Commercial Awareness – Developing an understanding of the commercial factors influencing successful sales.
Negotiation Skills – Building the confidence required to progress opportunities and achieve positive outcomes.
These skills are particularly important within Thorne & Derrick’s specialist industries, where customers depend on knowledgeable sales professionals to understand complex requirements and help identify appropriate technical solutions.
Recognising the Importance of Mentorship
The successful completion of an apprenticeship is supported not only by formal learning but also by the encouragement, knowledge and practical guidance provided in the workplace.
Special recognition goes to Laura McCabe, who mentored Charlie and Ella throughout their apprenticeship journeys.
Laura provided ongoing guidance as Charlie and Ella developed their skills, applied their learning within the workplace and progressed through the different stages of the programme.
Her contribution highlights the important role experienced colleagues play in helping apprentices build confidence, overcome challenges and fulfil their professional potential.
Congratulations from Thorne & Derrick
Managing Director Richard Derrick joined Laura and the wider Thorne & Derrick team in congratulating Charlie and Ella on their achievements.
Their success reflects the commitment they have shown to their professional development and demonstrates the value of combining structured learning with practical workplace experience.
We would also like to thank Gateshead Learning and Skills for the training and support provided throughout Charlie and Ella’s apprenticeships.
Congratulations, Charlie and Ella. Your achievements are a credit to your dedication, and everyone at Thorne & Derrick is extremely proud of you both.
Empowering Future Professionals
Charlie and Ella’s success reflects Thorne & Derrick’s belief in developing talented individuals who are equipped to progress within their careers and contribute to the continued success of the business.
Now equipped with nationally recognised Level 4 qualifications, Charlie and Ella are well positioned to continue building their experience, taking on new responsibilities and delivering value to Thorne & Derrick and its customers.
Their achievements also demonstrate the important role apprenticeships can play in nurturing talent, developing workplace skills and creating opportunities for meaningful career progression.
About Thorne & Derrick International
Thorne & Derrick International is a UK-based specialist distributor of LV, MV and HV cable accessories and tooling, complemented by an extensive range of hazardous area certified electrical equipment.
With more than 40 years of industry expertise, Thorne & Derrick supplies trusted products, technical support and tailored solutions to customers working across power, utilities, rail, construction, oil and gas, marine and process industries.
Thorne & Derrick remains committed to investing in its people and developing future-ready capabilities through apprenticeship programmes that nurture talent, strengthen workplace knowledge and support long-term career development.
On Friday 4th of September, Thorne & Derrick will be welcoming you to Faraday Power Group Event #FPG3. Â
We look forward to seeing clients, suppliers, service providers and professionals from the High Voltage Power Industry.
What is FPG?
Faraday Power Group is an informal, friendly, open-network of professional companies rooted in the North of England; Thorne & Derrick are founder members and are committed to providing full support to the evolving challenges and requirements of the Power Industry.
Together we improve safety, introduce innovation and open opportunities for all, that’s FPG.
Location: The Faraday Centre, Wilton Centre, Redcar
Date: Friday 4th of September
Time: 10:00 – 15:00
Cost:FREE for all Visitors
We’re gearing up for the Faraday Power Group Event #3, bringing together organisations from across the UK to collaborate, innovate and strengthen standards and opportunities across the electrical power industry.
We are committed to building cross-sector engagement across the Electrical Power Industry.
Many leading High Voltage Service Providers, Contractors, Manufacturers & Jointers are attending from across the UK for a day of knowledge sharing, professional introductions and networking to discuss our objectives and ambitions within the power industry.
What’s included (Free)
Exhibitor stall (round table + seating)
Chance to present or demonstrate your product/service
Networking with key companies across multiple sectors
Lunch includedfor exhibitors and attendees
Parking included
Transport available from the Wilton Centre Visitor’s Centre to The Faraday Centre
Guided facility tours of The Faraday Centre
Join Us for Demonstrations| You can try and test the Latest HV Tools used by HV Onshore & Offshore Jointers up to 66kV.
The Faraday Power Group is a collective of companies based in the North of England, working together to promote innovation, improve safety standards and support the evolving needs of the electrical power industry.
The upcoming event hosted at The Faraday Centre will bring together industry professionals, manufacturers and technical specialists for networking, knowledge sharing and live demonstrations.
Important Site Information
The Wilton Centre is a COMAH site, therefore all visitors (including exhibitors) must complete a quick visitor safety induction. If completed online beforehand via our instructions, your pass will be ready on arrival. If completed on the day, please allow an additional 15–20 minutes to physically complete it with the Falck induction team.
⛔ No under-18s Permitted/ Right Of Admission Reserved (COMAH site).
Watch our #FPG2 Video from the March 2027 EventÂ
Courtesy of Power Engineering Services Ltd.
Exhibitor Set-up
🕗 08:00 – 09:30
Stall space is compact – please plan for a round table display. You are welcome to bring a small banner and marketing materials, as well as demo products/merchandise. If you have any special requirements (power, equipment placement, product demonstrations), just let me know.
To Register Interest (Exhibit or Attend): please message :Â 📧 [email protected]
If you have dietary requirements or allergies, please include that in your reply so catering can accommodate appropriately.
We are incredibly proud of the innovation happening in the North East of England and want this to become a place where new partnerships, contracts and collaborations start.
It would be great to have you with us.
Thanks, and we hope to welcome you on the day.
Location
The Faraday Centre Ltd
The Wilton Centre Annexe
South Building
Wilton Centre
Redcar
TS10 4RF
Thorne & Derrick
Thorne & Derrick are Specialist Electrical Distributors of products to provide safe and reliable LV HV Cable Termination, Jointing, Installation & Power Systems from 600V to 66kV.
The PENTA VISARC arc flash helmet has been developed to protect one of the most exposed areas of an electrical worker’s body during an arc flash: the face.
Arc flash jackets, trousers, coveralls and switching suits can protect the body, but they do not automatically protect the eyes, forehead, cheeks, jawline, chin or sides of the face.
The VISARC Electrical Safety Helmet addresses this risk by combining an electrically insulating helmet shell, an integrated retractable face shield and, depending on the selected configuration, rigid chin and lateral protection.
This coordinated helmet system is designed to protect electrical workers against arc flash heat, ultraviolet radiation, molten-metal projections, high-speed particles and mechanical hazards while maintaining the visibility needed for detailed electrical work.
Available in APC1, APC2 12 cal/cm² and APC2 25 cal/cm² configurations, VISARC enables head and face protection to be selected according to the electrical risk assessment rather than applying one protection level to every task.
Thorne & Derrick supply the PENTA VISARC Helmet alongside arc flash clothing, insulating gloves and specialist electrical safety equipment for workers operating on or near LV, MV and HV Electrical Systems.
Quick Answer: How Does VISARC Protect the Face During an Arc Flash?
The PENTA VISARC Helmet combines an electrical safety helmet with an integrated arc flash face shield. APC2 configurations also incorporate rigid, retractable chin and lateral protection to extend protective coverage beneath and around the face.
The arc flash helmet is designed to protect against the thermal effects of an electrical arc, ultraviolet radiation, molten-metal projections, high-speed particles and mechanical hazards.
VISARC is available in three configurations: APC1, APC2 with an ATPV of 12 cal/cm² and APC2 with an ATPV of 25 cal/cm². The correct configuration must be selected through a competent electrical risk assessment.
PENTA VISARC Arc Flash Face Protection Helmet
PENTA VISARC: Quick Summary
What It Is
An integrated electrical safety helmet and arc flash face shield system developed by PENTA.
Areas Protected
Head, eyes and face, with extended chin and lateral facial protection depending on the configuration.
Arc Flash Configurations
APC1, APC2 ATPV 12 cal/cm² and APC2 ATPV 25 cal/cm².
Face Shield Performance
Optical Class 1, internally anti-fog and externally scratch-resistant.
Helmet Shell
Class 2 under EN 50365:2023 and tested up to 30kV.
Selection Requirement
The correct configuration must be selected according to the electrical risk assessment and complete PPE system.
What Is the PENTA VISARC Arc Flash Helmet?
The PENTA VISARC arc flash helmet is an integrated head and face protection system for electrical workers.
It has been designed to address several hazards within one coordinated assembly:
Thermal hazards from an electrical arc
Electrical risks affecting the head
Mechanical impact and penetration hazards
Ultraviolet radiation
Molten-metal projections
High-speed particles
Reduced visibility caused by fogging, scratches or distortion
Instead of attaching a separate face shield to a general-purpose helmet, VISARC integrates the helmet shell, face shield and protective frame into one system.
This is important because every component of Category III electrical PPE must work together as part of the certified arrangement.
The integrated system also helps protect the face shield when it is retracted into the helmet, reducing its exposure to accidental scratches and damage while it is not in use.
The VISARC principle: combine arc flash performance, electrical head protection, facial coverage and clear vision in one helmet rather than treating the visor as a separate accessory.
What Can an Arc Flash Do to the Face?
An arc flash is a rapid release of electrical energy through the air between conductors or from an energised conductor to an earthed surface.
The event can occur following insulation breakdown, accidental contact, equipment failure, contamination, loose connections, incorrect operation or the introduction of a conductive object.
An electrical arc may release:
Intense thermal energy
Visible and ultraviolet radiation
Molten and vaporised metal
High-speed equipment fragments
Hot gases and smoke
A powerful pressure wave
Extremely high noise levels
The face is particularly vulnerable because it may be close to the electrical equipment and is not protected by the garments covering the torso, arms or legs.
How Arc Flash Can Affect the Face
Eyes
Intense light, ultraviolet radiation, particles and molten metal can cause serious eye injury.
Exposed Skin
Thermal energy can cause severe burns to the forehead, cheeks, chin and other exposed areas.
Chin and Jawline
Heat and projected material may travel underneath a conventional face shield.
Sides of the Face
An arc may not be directly in front of the worker, leaving lateral facial areas exposed.
Head
The worker may be exposed to heat, impact, falling objects and fragments released from equipment.
Hearing
Arc blast noise and pressure can create a separate risk of hearing injury.
Arc flash exposure is not limited to high-voltage systems. Serious electrical arcs can occur on LV equipment as well as MV and HV systems.
The actual risk depends on the equipment, available fault current, protection clearing time, working distance, configuration and task being performed.
Why Is Arc Flash Clothing Not Enough to Protect the Face?
Arc flash clothing only protects the areas it covers.
An arc-rated jacket, pair of trousers or coverall may protect the torso, arms and legs, but those garments do not automatically protect the face.
A complete arc flash PPE system may also require:
An arc flash helmet
An arc-rated face shield or visor
Chin and lateral facial protection
An arc flash hood or balaclava
Safety glasses
Electrical insulating gloves
Suitable protective overgloves
Hearing protection
Appropriate safety footwear
VISARC has been designed specifically to address protection above the neckline.
The integrated helmet and face shield provide protection across the head, eyes and central facial area. The chin and lateral protection available within the VISARC range extends coverage around areas that may remain more exposed with a conventional open-bottom face shield.
Important: The VISARC helmet must still be worn as part of a complete PPE ensemble. A helmet does not replace suitable arc flash clothing, hand protection, hearing protection or any additional neck protection required by the risk assessment.
How Does VISARC Extend Arc Flash Protection Around the Face?
The design of the PENTA VISARC Helmet considers more than protection directly in front of the eyes.
An electrical arc can occur below, beside or at an angle to the worker. Heat, ultraviolet radiation and projected particles may therefore reach areas outside the centre of a conventional visor.
VISARC addresses this through a combination of:
An integrated face shield protecting the eyes and central facial area
A helmet shell protecting the upper head
Rigid protection beneath the face shield towards the chin
Lateral extensions around the sides of the face
Overlap between the protective components
A retractable design that allows the complete system to remain attached to the helmet
Coloured Helmet Crest Options
VISARC Facial Protection Areas
Eyes
Integrated arc flash face shield designed to protect against radiation, particles and molten-metal projection.
Forehead and Central Face
Coverage is provided by the combination of the helmet shell and lowered face shield.
Chin and Jawline
Rigid retractable protection extends beneath the visor on APC2 configurations and can be specified for APC1.
Sides of the Face
Lateral protection extends coverage around the sides of the face rather than protecting only from the front.
Upper Head
The helmet shell provides electrical and mechanical head protection under the relevant standards.
For the APC1 version, rigid chin and lateral protection can be specified as an accessory and may be removed where permitted by the approved configuration.
For the APC2 versions, the retractable chin and lateral protection forms part of the helmet’s certified arc flash arrangement.
Whole-face coverage should not be confused with full head-and-neck enclosure. Some higher-risk tasks may require an arc flash hood, balaclava, shroud or complete switching suit.
The correct arrangement must always be determined by the task-specific risk assessment.
How Does the VISARC Arc Flash Face Shield Perform?
The face shield is one of the most important elements of an arc flash helmet.
It must provide the required protective performance while allowing the electrical worker to see equipment, conductors, labels, indicators and test points clearly.
The VISARC face shield is designed to protect against:
Thermal effects from an electrical arc
Ultraviolet radiation
Molten-metal projections
High-speed particles
External scratching
Internal fogging
It provides Optical Class 1 performance, the highest optical classification, helping reduce image distortion, visual blur and eye fatigue.
The internal surface is treated to resist fogging, while the outside of the shield is scratch-resistant.
These characteristics are directly relevant to safe working performance.
A visor that fogs, becomes heavily scratched or distorts the worker’s view can make it more difficult to:
Identify cable and conductor markings
Read equipment labels
See warning indicators
Position tools accurately
Recognise damaged equipment
Maintain awareness of the surrounding work area
Clear vision is a safety feature: Optical performance helps the wearer keep the face shield lowered rather than repeatedly lifting it to obtain a clearer view of the task.
Why Are VISARC Chin and Lateral Protection Important?
A conventional face shield primarily protects the area directly in front of the wearer.
During an arc flash, however, the heat, radiation, molten metal and projected particles may not travel in a straight line towards the middle of the shield.
The electrical arc may be:
Below the worker’s eye level
To one side of the worker
Inside partially enclosed equipment
Reflected or channelled by the equipment enclosure
Directed around the lower or lateral edge of a visor
VISARC’s rigid chin and lateral protection extends the protected area beneath and around the face shield.
This helps reduce open areas around the jawline and sides of the face while maintaining a retractable system that remains integrated with the helmet.
The design is particularly relevant to electrical tasks involving:
Switchgear operation
Circuit-breaker racking
Electrical testing
Fault finding
Cable jointing and termination work
Maintenance inside electrical panels
Commissioning and inspection
The chin and lateral protection must remain in the approved position and configuration required for the selected VISARC protection level.
It should not be removed, modified or replaced with an unapproved component.
Arc Flash Protection up to 25Cal with VISARC
VISARC APC1, APC2 12 Cal and APC2 25 Cal Explained
The PENTA VISARC range is available in three principal arc flash protection configurations.
This allows the wearer or duty holder to select the appropriate system using the findings of the electrical risk assessment.
PENTA VISARC Protection Configurations
VISARC Configuration
Arc Flash Performance
Chin and Lateral Protection
VISARC APC1
APC1 box-test classification. This version does not have an open-arc ATPV rating.
Rigid or fabric lateral protection can be selected as an approved option.
VISARC APC2 – 12 cal/cm²
APC2 box-test classification with an ATPV of 12 cal/cm².
Rigid retractable chin and lateral protection is integrated into the certified configuration.
VISARC APC2 – 25 cal/cm²
APC2 box-test classification with an ATPV of 25 cal/cm².
Rigid retractable chin and lateral protection is integrated into the certified configuration.
VISARC APC1
The APC1 version provides Class 1 electrical arc protection under the box-test method.
It does not use an ATPV value from an open-arc test and should not be described as a particular cal/cm² helmet unless supported by specific manufacturer certification.
Rigid chin and lateral protection can be added to the APC1 helmet using the approved mounting points. A flame-resistant fabric lateral protection option is also available.
VISARC APC2 – 12 cal/cm²
The 12 cal/cm² version combines APC2 box-test performance with an ATPV of 12 cal/cm².
It includes the integrated retractable chin and lateral protection system, extending the protected area beneath and around the face shield.
VISARC APC2 – 25 cal/cm²
The 25 cal/cm² configuration provides the highest arc rating within the VISARC range.
It combines APC2 box-test classification with an ATPV of 25 cal/cm² and the integrated retractable chin and lateral protection system.
Do not select by rating alone: The correct VISARC helmet depends on the calculated or assessed incident energy, task, equipment, working distance, protection clearing time and complete PPE ensemble.
Which Standards Does the PENTA VISARC Helmet Meet?
The standards applying to VISARC depend on whether the component being considered is the helmet shell, face shield or complete helmet-and-shield assembly.
PENTA VISARC Standards
Component
Standard
Purpose
Helmet
EN 397:2025
Industrial safety helmet requirements, including relevant impact and penetration performance.
Helmet
EN 50365:2023
Electrically insulating helmets for use on low-voltage installations. The VISARC shell is Class 2 and tested up to 30kV.
Face Shield
EN ISO 16321-1:2022
General occupational eye and face protection requirements.
Helmet and Face Shield Assembly
EN IEC 62819:2023
Eye, face and head protectors against the effects of electric arc.
Standards provide evidence of performance under defined test conditions. They do not mean that one helmet configuration is suitable for every electrical installation or task.
The 30kV test level of the helmet shell must not be treated as a general working-voltage recommendation for the complete PPE system.
Electrical PPE selection should be based on the specific hazard, task, system and risk assessment.
Why Do Visibility and Optical Quality Matter During Electrical Work?
Protection is only effective when the worker can wear it correctly throughout the task.
Electrical work can involve small conductors, closely spaced terminals, labels, test points and equipment indicators. Poor visibility can increase the possibility of mistakes.
The VISARC face shield is designed to reduce:
Image distortion
Visual blur
Eye fatigue
Internal fogging
Obstruction caused by surface scratches
Its Optical Class 1 performance supports extended use where clear vision is essential.
The face shield also provides a high level of visible light transmission for its protection class, helping the user work without unnecessarily lifting the shield.
How VISARC Visibility Supports Safer Working
Optical Class 1
Helps minimise distortion during prolonged use.
Internal Anti-Fog Treatment
Helps maintain visibility during changing temperatures and physically demanding work.
External Scratch Resistance
Helps maintain the clarity of the visor during normal handling and use.
Integrated Storage Position
The visor retracts into the helmet system, helping protect it when it is not lowered.
A scratched or damaged face shield must still be inspected and replaced where required. Scratch resistance does not make the surface immune to damage.
Why Does the Integrated VISARC Helmet Design Matter?
Arc flash head protection is sometimes assembled from a helmet, separate visor carrier and additional components.
VISARC has instead been developed as a coordinated system.
The integrated design provides several practical benefits:
The face shield remains attached to the helmet
The shield can be lowered and retracted as part of the same system
The helmet structure protects the shield while it is raised
Chin and lateral protection remain aligned with the face shield
The certified components are designed to work together
The system is balanced for prolonged electrical work
Approved accessories use designated mounting positions
The helmet uses a double-shell design that helps protect the retracted face shield and prolong its usable condition.
This is particularly important because scratches, cracks, chemical contamination or unapproved modifications can affect the performance of an arc flash face shield.
An integrated system also reduces the need to assemble unrelated helmet and visor components on site.
Certified as a system: The VISARC helmet, face shield and protective components should remain within the manufacturer-approved configuration. Substituting components may invalidate certification.
Can VISARC Protection Be Customised for Different Electrical Workers?
VISARC has been designed as a modular helmet platform.
This allows the helmet to be configured around the role, working environment and required level of protection without changing the certified protection level of the selected helmet.
Available options can include:
Rigid chin and lateral protection for APC1
Flame-resistant fabric lateral protection
Integrated headlamp modules
Personal voltage alarm options
Neck protection against ultraviolet radiation
Retroreflective strips
Approved hearing protection
Coloured helmet crests for role identification
Company logo personalisation
Coloured crests can be used to distinguish teams or responsibilities on a shared site, such as different authorised roles or work supervisors.
Integrated electronic modules can combine a headlamp with additional functions, including rear visibility lighting and a personal electric-field alarm.
A personal voltage alarm is an additional warning device. It must not replace:
Safe isolation
Approved voltage detection procedures
Test-before-touch requirements
Electrical risk assessment
Site safety rules
Not every accessory combination is compatible. The approved manufacturer configuration must be checked before combining lateral protection, hearing protection, lighting or electronic modules.
How Should a VISARC Arc Flash Helmet Be Selected?
The correct VISARC configuration should be selected using the results of a competent electrical risk assessment.
It should not be selected using voltage alone.
Important factors include:
The electrical task being performed
The system voltage
The available fault current
The protection clearing time
The predicted or calculated incident energy
The equipment type and configuration
The condition and maintenance history of the equipment
The working distance
The position of the worker
The possibility of a constrained or directed arc
The clothing and other PPE being worn
The need for additional neck or hearing protection
VISARC Selection Checklist
Identify the Task
Confirm whether the work involves switching, testing, maintenance, inspection, cable jointing, fault finding or commissioning.
Assess the Arc Hazard
Use available arc flash study data or a competent task-specific risk assessment.
Choose the Protection Level
Compare the assessed exposure with the APC classification and ATPV of the helmet.
Review Facial Coverage
Consider whether chin, lateral, neck or complete hood protection is required.
Check the Complete PPE System
Ensure the helmet is compatible with the selected clothing, gloves, eye protection and hearing protection.
Confirm Accessory Compatibility
Use only PENTA-approved accessories and combinations for the selected helmet.
Check Fit and Adjustment
Adjust the helmet to the individual wearer and verify that the face shield lowers and locks correctly.
A higher arc rating is not automatically the best choice for every task.
The selected helmet should provide adequate protection without unnecessarily reducing visibility, mobility or comfort.
Who May Need a PENTA VISARC Arc Flash Helmet?
VISARC may be considered wherever electrical workers could be exposed to electric arc hazards during operation, testing, inspection, maintenance or fault conditions.
Potential users include:
Cable jointers
Authorised and senior authorised persons
Electrical maintenance technicians
Switchgear engineers
Substation engineers
Utility workers and linesmen
Industrial electricians
Rail and traction-power engineers
Renewable-energy technicians
Data-centre electrical teams
Battery energy storage technicians
Electric-vehicle infrastructure engineers
Electrical testing and commissioning personnel
VISARC may be used within industries such as:
Electricity transmission and distribution
Utilities and substations
Manufacturing and industrial processing
Rail infrastructure
Renewable energy
Data centres
Oil, gas and petrochemical facilities
Marine and offshore installations
Battery storage
Commercial power distribution
The industry or job title does not determine the correct helmet. Selection must be based on the actual task and electrical hazard.
Can the PENTA VISARC Helmet Prevent an Arc Flash?
No helmet or item of PPE can prevent the electrical fault itself.
VISARC is designed to reduce the potential severity of injury if an arc flash occurs within the tested limitations of the selected helmet configuration.
Preventing the event and avoiding exposure must remain the priority.
Arc flash risk management should consider:
Predict – identify the arc hazard and assess its possible severity.
Prevent – eliminate the hazard or reduce the likelihood and severity of an event.
Process – implement competent people, safe procedures and controlled working practices.
Protect – select suitable PPE for any residual risk that remains.
Risk reduction measures may include:
De-energising and safely isolating equipment
Remote switching or operation
Increasing working distance
Reviewing protection settings
Using arc-resistant equipment
Improving equipment maintenance
Restricting access
Providing electrical safety training
Implementing task-specific procedures
Wearing correctly selected arc-rated PPE
PPE is the final line of defence: Wearing a VISARC helmet does not make unnecessary live working safe and should never replace safe isolation or competent electrical procedures.
How Should the VISARC Helmet Be Inspected and Maintained?
The VISARC helmet should be inspected before each use.
Checks should include:
No cracks, splits or visible damage to the helmet shell
No serious scratches, cracks or damage to the face shield
No signs of chemical contamination
The face shield lowers fully
The face shield clips correctly onto its frame
The chin and lateral protection moves and locks correctly
The harness and chinstrap are secure
Accessories are fitted in accordance with PENTA instructions
No unapproved modifications have been made
Any helmet that has sustained a significant impact should be replaced, even where damage is not immediately visible.
For cleaning:
Clean the helmet using lukewarm soapy water or a suitable soft wipe
Allow the helmet to dry at room temperature
Use the supplied microfibre cloth to remove dust from the face shield
Use lukewarm water without soap for more thorough visor cleaning
Do not use products containing solvents
Follow the full instructions supplied with the helmet
PENTA states that the helmet can be stored for up to three years from its manufacturing date and used for up to five years from the date of first use, provided that it continues to pass the required pre-use inspections.
Actual replacement may be required earlier if the helmet is damaged, contaminated, modified, subjected to impact or fails inspection.
Common PENTA VISARC and Arc Flash Helmet Mistakes
Incorrect selection or use can create gaps in protection.
Common mistakes include:
Selecting the helmet using voltage alone – arc flash severity also depends on fault current, clearing time, equipment configuration and working distance.
Assuming arc flash clothing protects the face – garments only protect the areas they cover.
Treating an ordinary visor as arc flash protection – general impact or splash protection does not automatically provide certified electrical arc protection.
Removing APC2 chin protection – the integrated protection is part of the certified APC2 configuration.
Changing the face shield to alter the protection level – the originally certified VISARC protection level must be maintained.
Mixing unapproved components – unrelated helmets, shields and accessories may invalidate the certified arrangement.
Using a damaged or heavily scratched visor – damage can affect visibility and protective performance.
Ignoring the chin and sides of the face – an electrical arc may occur below or beside the worker.
Assuming the highest rating suits every task – PPE should be proportionate to the assessed exposure.
Using the voltage alarm as a voltage detector – a personal alarm does not replace safe isolation or approved voltage testing.
Failing to inspect the helmet – cracks, impact damage or contaminated components may prevent the helmet performing as intended.
Assuming PPE prevents the incident – VISARC reduces potential injury but cannot prevent an electrical fault.
Related VISARC and Arc Flash Safety Products
The VISARC helmet should be selected as part of a complete electrical safety PPE system.
PENTA VISARC Arc Flash Helmet – integrated head and face protection available in APC1, APC2 12 cal/cm² and APC2 25 cal/cm² configurations.
A: PENTA VISARC is an integrated electrical safety helmet and arc flash face shield system. It provides electrical and mechanical head protection alongside certified face protection against electrical arc hazards.
Q: Does the VISARC helmet protect the whole face?
A: The integrated face shield protects the eyes and central facial area. Rigid chin and lateral protection extends coverage beneath and around the face. This protection is integrated into APC2 models and available as an approved option for APC1. Some tasks may still require additional neck protection or a complete arc flash hood.
Q: What protection levels are available?
A: VISARC is available in three principal configurations: APC1, APC2 with an ATPV of 12 cal/cm² and APC2 with an ATPV of 25 cal/cm².
Q: What is the difference between VISARC APC1 and APC2?
A: APC1 and APC2 represent different box-test arc protection classes. APC2 involves the more severe test exposure. VISARC APC2 models are also available with ATPV ratings of 12 or 25 cal/cm² and include integrated chin and lateral protection.
Q: Is the APC1 VISARC helmet rated in cal/cm²?
A: No open-arc ATPV rating is stated for the APC1 VISARC configuration. It is classified using the APC1 box-test method and should not be assigned a cal/cm² value without specific manufacturer evidence.
Q: Is a 25 cal VISARC helmet always better than a 12 cal helmet?
A: The 25 cal configuration has a higher tested arc rating, but the correct helmet should be selected according to the assessed incident energy, task, visibility, working conditions and complete PPE system. The highest rating is not automatically required for every application.
Q: Can the VISARC face shield be changed to alter the arc protection level?
A: No. The protection level originally certified and supplied by PENTA must be maintained. Changing Category III PPE components outside the approved configuration may invalidate the certification.
Q: Is the VISARC face shield anti-fog and scratch-resistant?
A: Yes. The face shield has anti-fog treatment on its internal surface and scratch-resistant treatment on its external surface. It should still be inspected before use and replaced if damaged.
Q: What optical class is the VISARC face shield?
A: The VISARC face shield provides Optical Class 1 performance, helping reduce image distortion and visual fatigue during extended use.
Q: Does arc flash clothing protect the face?
A: No. Arc flash garments protect only the areas they cover. A certified arc flash helmet, face shield or hood may be required to protect the head, eyes and face.
Q: Is an ordinary safety visor suitable for arc flash protection?
A: Not necessarily. General impact or splash protection does not automatically provide protection against electrical arc hazards. The visor must have the appropriate arc flash certification and performance for the task.
Q: Can VISARC be used for LV, MV and HV electrical work?
A: VISARC may form part of the PPE used across LV, MV and HV environments, but suitability cannot be decided from voltage alone. The task, system, incident energy, working distance and complete risk assessment must be considered.
Q: Can VISARC include a voltage alarm?
A: VISARC can be configured with an integrated headlamp and personal electric-field alarm. The alarm is an additional warning device and does not replace approved voltage detection, safe isolation or test-before-touch procedures.
Q: How long does a VISARC helmet last?
A: PENTA states a maximum storage period of three years from manufacture and a maximum in-use period of five years from first use, subject to correct storage, maintenance and successful pre-use inspection. Damage or impact may require earlier replacement.
Q: Can the VISARC helmet prevent an arc flash?
A: No. VISARC is designed to reduce potential injury if an arc flash occurs within the helmet’s tested limitations. It cannot prevent the electrical fault. Isolation, risk reduction and safe working procedures remain the priority.
Conclusion: Arc Flash Protection Should Not Stop at the Collar
An arc flash can expose the eyes, skin, chin and sides of the face to intense heat, ultraviolet radiation, molten metal and high-speed particles.
Arc flash clothing can protect the body, but it cannot protect facial areas that remain uncovered.
The PENTA VISARC arc flash helmet has been developed to address this gap through an integrated helmet, retractable face shield and configurable chin and lateral protection system.
Its Optical Class 1 visor, anti-fog and scratch-resistant surfaces, integrated double-shell design and three protection configurations provide a flexible head and face protection platform for electrical workers.
The range includes:
VISARC APC1
VISARC APC2 with an ATPV of 12 cal/cm²
VISARC APC2 with an ATPV of 25 cal/cm²
The correct configuration must always be selected through a competent arc flash risk assessment and worn with suitable clothing, gloves, hearing protection and any additional head or neck protection required for the task.
Thorne & Derrick supply PENTA VISARC helmets, arc flash clothing, face protection, insulating gloves and electrical safety PPE for LV, MV and HV electrical workers operating across utilities, substations, rail, renewables, data centres, industry and power distribution.
Cable trough is a protective cable containment system used to route, support and protect power, signalling, telecoms, control and communications cables above ground or at shallow depth. Cable troughing is commonly used across railways, substations, highways, utilities, industrial sites, renewable energy projects and electrical infrastructure.
In simple terms, a cable trough provides a defined channel for cables. The trough helps protect cables from mechanical damage, weather exposure, accidental impact, vegetation, debris and unauthorised interference, while still allowing access for inspection, repair, cable jointing and future cable additions.
Cable troughs are available in different materials and formats, including concrete cable troughs, GRC cable troughs, lightweight composite troughs, straight sections, lids, T-pieces, bends, transitions, channels and elevated troughing systems.
Cable trough is a cable protection and containment system used to route cables safely through rail, power, highway and infrastructure environments. It normally consists of a channel or trough section with a removable lid, allowing cables to be protected while still remaining accessible for inspection, maintenance and future installation work.
Cable troughing is commonly used for LV, MV and HV power cables, signalling cables, telecoms cables, control cables and communications cables. It is especially common in trackside rail environments, substations, power networks and utility cable routes.
Cable Trough: Quick Summary
What It Is
A protective channel system used to route and protect cables while allowing access for maintenance.
Main Purpose
To protect cables from mechanical damage, environmental exposure and route disruption.
Common Materials
Concrete, GRC, composite and other lightweight cable protection materials.
Typical Uses
Rail, trackside, highways, substations, utilities, renewables, industrial sites and power distribution routes.
A cable trough is a physical containment route used to house and protect cables. Unlike a buried duct where the cable is pulled through an enclosed pipe, a cable trough is usually an open channel with a lid fitted over the top.
This makes cable troughing useful where cables need both protection and future access. The lid can be removed so engineers can inspect cables, install additional circuits, carry out jointing work or repair damaged sections without excavating a fully buried route.
Cable troughing systems can be used for:
Power cables
Rail signalling cables
Telecommunications cables
Control and instrumentation cables
Fibre optic cables
Substation auxiliary cables
Trackside and infrastructure cable routes
The correct trough system depends on cable type, cable quantity, route layout, loading requirement, access needs, ground conditions and project approval requirements.
Where Is Cable Trough Used?
Cable troughing is used where cables need mechanical protection and accessible containment.
Typical locations include:
Railway trackside routes – protecting power, signalling and telecoms cables along rail infrastructure.
Substations – routing LV, MV and HV power, control and auxiliary cables.
Highways – protecting cables for lighting, traffic systems, signage and communications.
Utilities – housing power and communications cables across infrastructure networks.
Renewable energy sites – protecting cable routes for solar, wind and battery storage projects.
Industrial sites – protecting cables in outdoor process, plant and utility areas.
Bridges, tunnels and embankments – where elevated or lightweight cable troughing may be required.
Cable trough is especially useful where a cable route must remain accessible after installation.
Types Of Cable Trough
Cable troughs are available in different materials and shapes to suit different route conditions.
Common Types Of Cable Trough
Concrete Cable Trough
Robust troughing used for permanent cable protection, especially in rail and infrastructure environments.
GRC Cable Trough
Glassfibre reinforced concrete troughing used where lighter weight, elevated routes or difficult access make traditional concrete less practical.
Lightweight Composite Trough
Modern lightweight troughing used for rail, light rail, highways and power applications where faster handling may be required.
Elevated Cable Trough
Troughing installed above ground or on support structures, often used on bridges, tunnels, embankments and trackside routes.
Cable Trough Lids
Removable covers fitted to trough sections to protect cables while allowing future access.
Cable trough systems may also include straight sections, bends, T-pieces, transitions, joint boxes, brackets, stakes and direction-change accessories.
Concrete Cable Trough
Concrete cable trough is one of the most established cable protection methods used in rail and infrastructure projects. It provides strong, durable, permanent cable containment with removable lids for future access.
Concrete troughs are used to protect power, signalling, telecoms and communication cables from physical damage and environmental conditions. They are particularly common on rail infrastructure, where trackside cable routes need long service life and reliable protection.
Benefits of concrete cable troughing include:
High mechanical strength
Long-term cable protection
Removable lids for access
Suitable for rail and infrastructure projects
Protection from environmental and mechanical damage
Support for future cable jointing, repairs and additions
Power & Cables supplies concrete cable troughs for LV, 11kV, 25kV and 33kV trackside cable protection, including Anderton concrete troughing and Anderlite lightweight concrete trough systems.
GRC Cable Trough
GRC cable trough is manufactured from glassfibre reinforced concrete. It is used where a lighter weight troughing system is needed while still providing cable support and protection.
GRC troughing is commonly used at trackside ground level, over bridges and through tunnels. It can be useful in locations where manual handling, access, elevated installation or route flexibility are important.
Railway infrastructure is one of the most common applications for cable troughing. Trackside cable routes must protect power, signalling and telecoms cables while allowing access for maintenance and network changes.
Rail cable troughing is used for:
Signalling cables
Telecommunications cables
Trackside power cables
Control cables
LV and MV cable routes
Tunnel, bridge and elevated route sections
In rail environments, cable trough may need to meet project-specific approvals, load requirements, route design and installation standards. Troughing may also need bends, transitions, tee sections and lightweight alternatives for difficult access locations.
Cable Trough For Power Cables
Cable trough is also used for power cable protection in substations, industrial sites, utilities and renewable energy projects. It can provide a protected route for LV, MV and HV cables while allowing future access for inspection and maintenance.
Power cable troughing can be used where:
Cables require mechanical protection
Cable routes must remain accessible
Future cable additions are likely
Jointing or repair access may be required
Above-ground or shallow-depth cable protection is preferred
Cable ducts are not the most practical route method
A: Cable trough is a protective cable containment system used to route and protect power, signalling, telecoms, control and communications cables. It usually consists of a channel with a removable lid.
Q: What is cable trough used for?
A: Cable trough is used to protect and contain cables in rail, power, highway, utility, substation, industrial and infrastructure environments while allowing access for inspection and maintenance.
Q: What is concrete cable trough?
A: Concrete cable trough is a robust cable containment system used for permanent cable protection, especially in rail and infrastructure applications. It normally includes concrete trough sections and removable lids.
Q: What is GRC cable trough?
A: GRC cable trough is glassfibre reinforced concrete troughing. It is used where a lighter weight cable trough system is required, including rail, bridges, tunnels and elevated route sections.
Q: What is the difference between cable trough and cable duct?
A: Cable trough is usually an accessible channel system with removable lids. Cable duct is an enclosed pipe or duct route through which cables are pulled, often underground. Troughing is better where future access is important.
Q: Where is rail cable trough used?
A: Rail cable trough is used along trackside routes, bridges, tunnels and rail infrastructure to protect power, signalling, telecoms and control cables while keeping them accessible for maintenance.
Q: Can cable trough be used for power cables?
A: Yes. Cable trough can be used for LV, MV and HV power cables where the route needs protection and access. It is also used for signalling, telecoms, fibre optic and control cables.
Q: How do you choose the right cable trough?
A: To choose the right cable trough, check the application, cable type, internal capacity, loading requirement, route layout, material, access requirements and project approvals.
Conclusion
Cable trough is an important cable protection and containment system used across rail, power, highway, utility and infrastructure environments. It provides a protected cable route while allowing access for inspection, maintenance, repair, jointing and future cable additions.
Concrete cable trough, GRC cable trough and lightweight troughing systems each have different benefits depending on the route, loading requirement, access needs and project specification.
Thorne & Derrick supply cable troughing, concrete cable troughs, GRC cable troughs, cable trough lids, cable ducts and cable protection products for LV, MV and HV power, signalling, telecoms and infrastructure cable routes.
Cable glands are mechanical cable entry devices used to secure, seal and protect cables where they enter electrical equipment, enclosures, junction boxes, control panels, motors, switchgear, lighting, instrumentation and hazardous area equipment.
In simple terms, a cable gland provides a controlled entry point for the cable. Depending on the cable type and application, the gland may provide cable retention, environmental sealing, armour clamping, earth continuity, strain relief, ingress protection and explosion protection certification.
Cable glands are used across LV, MV and HV electrical installations, including industrial plants, utilities, substations, process facilities, offshore platforms, petrochemical sites, rail infrastructure, renewable energy projects, commercial buildings and hazardous area installations.
Cable glands are fittings used to terminate and secure cables where they enter electrical equipment or enclosures. They help seal the cable entry, retain the cable mechanically and protect the installation from dust, moisture, impact, vibration and environmental conditions.
For armoured cables, the cable gland may also clamp the armour and provide earth continuity. For hazardous area equipment, certified cable glands may be required to maintain the explosion protection concept of the enclosure or equipment.
Cable Glands: Quick Summary
What They Are
Cable entry fittings used to secure, seal and terminate cables into electrical equipment or enclosures.
Main Purpose
To provide cable retention, sealing, strain relief, ingress protection and, where required, armour continuity.
Used With
Armoured cables, unarmoured cables, SWA, AWA, braided cables, screened cables, control cables and instrumentation cables.
Common Applications
Industrial, commercial, hazardous area, offshore, petrochemical, utilities, substations and power distribution systems.
A cable gland is a component fitted to the entry point of an electrical enclosure or item of equipment. It allows a cable to enter the enclosure while maintaining the required mechanical and environmental protection.
Without a suitable cable gland, a cable entry can become a weak point in the installation. Water, dust, gas, chemicals or contaminants may enter the enclosure, and the cable may not be properly retained against pulling, vibration or movement.
Cable glands are commonly used on:
Junction boxes
Control panels
Motors and pumps
Switchgear
Lighting equipment
Instrumentation equipment
Hazardous area enclosures
Industrial power distribution equipment
The correct gland depends on the cable construction, equipment entry, installation environment, required IP rating, material, certification and whether the cable is armoured or unarmoured.
What Do Cable Glands Do?
Cable glands can perform several functions at the same time.
Main Functions Of Cable Glands
Cable Retention
Secures the cable so it is not easily pulled out of the enclosure or equipment.
Environmental Sealing
Helps prevent water, dust, dirt and contaminants entering the equipment through the cable entry.
Armour Clamping
For armoured cables, the gland clamps the armour wires, braid, tape or strip depending on cable construction.
Earth Continuity
For metallic armoured cables, the gland can support electrical continuity between the cable armour and equipment earth system.
Strain Relief
Reduces mechanical stress on cable terminations inside the enclosure.
Certification Integrity
For hazardous areas, certified glands help maintain the required explosion protection concept of the equipment.
Not every cable gland provides every function. A simple unarmoured gland may provide sealing and retention, while an armoured hazardous area barrier gland may provide sealing, retention, armour clamping, earth continuity and Ex certification.
Types Of Cable Glands
Cable glands are available in many types because cable construction and installation environments vary widely.
Common cable gland types include:
Unarmoured cable glands – for cables without armour, braid or metallic mechanical protection.
Armoured cable glands – for SWA, AWA, braided, strip armoured or tape armoured cables.
Industrial cable glands – for general industrial power, control and instrumentation applications.
Hazardous area cable glands – certified glands for explosive atmospheres and ATEX/IECEx equipment.
Barrier cable glands – glands that use a sealing compound or barrier seal where required by the protection concept or installation standard.
High temperature cable glands – for installations exposed to elevated temperatures.
EMC cable glands – designed to support electromagnetic compatibility and screen continuity.
Corrosion-resistant cable glands – often stainless steel or nickel-plated brass for harsh environments.
One of the most important selection decisions is whether the cable is armoured or unarmoured.
Armoured vs Unarmoured Cable Glands
Unarmoured Cable Gland
Used for cables without armour. It normally provides outer sheath sealing, retention and strain relief depending on the gland design.
Armoured Cable Gland
Used for cables with armour, such as SWA, AWA, braid, strip or tape armour. It clamps the armour and may provide earth continuity.
Selection Note
The gland must match the cable construction, not just the outside diameter or thread size.
For example, a gland for a multicore SWA cable may not be the correct option for a single-core AWA cable, braided cable or lead sheath cable. The armour type, bedding diameter, outer sheath diameter and environmental sealing requirement should all be checked.
For CMP SWA gland options, see CMP CW cable glands for steel and aluminium wire-armoured cables.
CMP Cable Glands
CMP cable glands are widely used across industrial, hazardous area, onshore, offshore, power, control, instrumentation and MV/HV cable installations. They are a major cable gland manufacturer and a key part of the Power & Cables gland range.
CMP gland ranges include products for:
Armoured cables
Unarmoured cables
Braided cables
Lead sheath cables
SWA and AWA power cables
Industrial installations
Hazardous areas
Medium and high voltage systems
Common CMP cable gland families include CW glands, BW glands, A2 glands, E1W, E2W, CXT, SOLO, ZEN, Triton and barrier gland ranges. The correct range depends on the cable construction, equipment certification, sealing method and installation environment.
Hazardous area cable glands are used where cables enter equipment installed in potentially explosive atmospheres. These environments may be found in oil and gas, petrochemical, chemical, pharmaceutical, offshore, tank storage, fuel handling, grain processing and other hazardous-area industries.
In hazardous areas, the cable gland must be compatible with the equipment protection concept, cable type and hazardous area classification. A standard industrial cable gland is not automatically suitable.
Hazardous area cable gland considerations include the following:
ATEX and IECEx certification
Zone 1 or Zone 2 requirements
Ex d, Ex e, Ex nR or Ex ta protection concepts
Armoured or unarmoured cable construction
Barrier or non-barrier sealing requirements
Ingress protection and environmental sealing
Material suitability for corrosion or offshore conditions
Cable gland material should be selected according to the environment, mechanical requirement, corrosion risk, cable type and equipment material.
Common Cable Gland Materials
Brass
Commonly used for general industrial cable glands and many armoured cable applications.
Nickel-Plated Brass
Used where improved corrosion resistance or finish is required compared with plain brass.
Stainless Steel
Used in harsh, corrosive, offshore, marine, chemical or petrochemical environments.
Aluminium
Used for selected applications where lightweight metallic gland construction is required.
Plastic / Polymer
Used for selected non-metallic enclosures, control cables and general cable entry applications.
For corrosive onshore or offshore locations, protective finishes or 316 stainless steel glands may be required depending on the environment.
Locknuts, Earth Tags, Shrouds & Accessories
Cable glands are often installed with accessories. These accessories help secure the gland, provide earth bonding, protect the gland body or adapt the gland to the enclosure entry.
Common cable gland accessories include:
Locknuts – used to secure the gland to an enclosure when a threaded entry is not available.
Earth tags – used to provide an earth bonding connection at the gland entry.
Shrouds – used to provide additional environmental protection over the gland body.
Sealing washers – used to help maintain ingress protection at the enclosure entry.
Reducers – used where the gland thread is smaller than the equipment entry.
Adaptors – used where thread conversion or entry size adjustment is required.
Stopping plugs – used to close unused entries in an enclosure.
Cable gland kits are commonly ordered with a locknut, earth tag and shroud where these accessories are required for the installation.
How To Select Cable Glands
Selecting the correct cable gland requires accurate cable and site information. A gland should not be selected from thread size alone.
Cable Gland Selection Checklist
Cable Type
Confirm whether the cable is armoured, unarmoured, SWA, AWA, braided, screened, tape armoured or lead sheath.
Cable Dimensions
Check bedding diameter, armour range and overall cable diameter using accurate cable data.
Thread Type & Size
Confirm metric, NPT or other thread requirements and check equipment entry compatibility.
Environment
Consider indoor, outdoor, underground, offshore, corrosive, industrial, UV, washdown or hazardous area exposure.
Ingress Protection
Check the IP rating and whether sealing washers, shrouds or additional sealing methods are required.
Certification
For hazardous areas, confirm ATEX, IECEx and equipment protection requirements.
Material
Select brass, nickel-plated brass, stainless steel, aluminium or polymer depending on the environment and specification.
Accessories
Check whether locknuts, earth tags, shrouds, reducers, adaptors, washers or stopping plugs are required.
Cable Tools – cutting, stripping, crimping and installation tools for cable termination work.
Cable Glands FAQs
Q: What is a cable gland?
A: A cable gland is a fitting used to secure, seal and terminate a cable where it enters electrical equipment or an enclosure. It helps provide cable retention, environmental protection and strain relief.
Q: What do cable glands do?
A: Cable glands can provide sealing, mechanical retention, strain relief, ingress protection, armour clamping, earth continuity and certification integrity depending on the gland type and installation.
Q: What is an armoured cable gland?
A: An armoured cable gland is designed for cables with metallic armour, such as SWA, AWA, braid, strip or tape armour. It clamps the armour and may provide earth continuity between the cable armour and equipment.
Q: What are CMP glands?
A: CMP glands are cable glands manufactured by CMP Products. They are used for industrial, hazardous area, high voltage, armoured, unarmoured, braided and specialist cable termination applications.
Q: What is an ATEX cable gland?
A: An ATEX cable gland is a certified gland used with equipment installed in potentially explosive atmospheres. It must be suitable for the hazardous area zone, equipment protection concept and cable type.
Q: What is included in a cable gland kit?
A: A cable gland kit often includes the cable gland plus accessories such as a locknut, earth tag and shroud. The exact kit contents depend on the manufacturer and ordering reference.
Q: How do you choose the correct cable gland size?
A: Cable gland size should be selected using the cable bedding diameter, armour range, overall cable diameter, cable construction and equipment thread size. It should not be selected by thread size alone.
Q: Do cable glands need earth tags?
A: Earth tags may be required where an earth bonding connection is needed at the gland entry, particularly where the cable armour forms part of the earthing arrangement. The requirement depends on the installation design and equipment.
Conclusion
Cable glands are essential cable entry components used to secure, seal and terminate cables into electrical equipment and enclosures. They support cable retention, environmental protection, strain relief, armour clamping, earth continuity and hazardous area certification where required.
Correct cable gland selection depends on the cable type, armour construction, bedding diameter, overall cable diameter, thread size, installation environment, material, IP rating, certification and accessory requirements.
Thorne & Derrick supply industrial cable glands, CMP cable glands, armoured cable glands, ATEX cable glands and hazardous area cable glands for LV, MV and HV power, control, instrumentation and electrical equipment installations.
What Is Arc Flash PPE and Why Is It Important? Arc flash PPE is specialist personal protective equipment designed to help protect electrical workers against the thermal hazards of an electric arc. It includes arc-rated clothing, protective helmets, face...
Voltage detectors are electrical safety instruments used to identify the presence or absence of voltage on electrical equipment and conductors. They are used by electricians, electrical engineers, utilities and maintenance teams working on low voltage (LV), medium voltage (MV)...