Arc Flash Jacket Category 2 9.5 Cal

Arc Flash Jacket Category 2 9.5 Cal

Arc Flash Jacket Category 2 9.5 Cal

ARC FLASH CLOTHING

Category 2 Jacket By ProGARM 

ProGARM Arc Flash Jacket provides Category 2 protection against arc flash with 9.5cal/cm2 according to IEC 61482-1-1:2009 ‘open arc’ test method.

Should you require guidance on selection and use of an Arc Flash Calculator please call Thorne & Derrick, the UK’s leading specialist distributor of electrical safety equipment for LV (Low Voltage), MV (Medium Voltage) and HV (High Voltage).

Arc flash jacket sizes range from S-4XL.

The well designed arc jacket features reflective tape and the lightweight VXS+ Flame Resistant fabric whilst ensuring outstanding Arc Flash protective properties.

Arc Flash Protection

  • IEC 61482-1-1:2009 Open Arc Test Method Cal Rating – 9.5cal/cm2
  • IEC 61482-1-2:2009 Box Test Method Class 1 or Class 2 – Class 1 4kA

Arc Flash Jacket Category 2

Features & Benefits

  • Category 2 Arc Flash Protection
  • Mandarin collar – maximum neck protection
  • Vertical chest pocket on jacket with zipper – discreet design
  • Gas monitor loop – secure fixing point
  • SafetyICONTM on arm – visual EN Standards icon system
  • 5cm Flame Resistant Anti Static Reflective Tape – double stitched for longer life
  • Phone Pocket on sleeve with flap – safe and secure
  • Velcro® secured cuff tabs – close fit around wrist or gloves
  • Side access pockets with flaps – prevents entry of debris
  • ThermSAFETM plastic Flame Resistant zipper – CE Certified
  • Extended back – protection when bending over
  • Triple stitched side seams – Lifetime quality assurance
  • Easy-StretchTM side panels – maximum wear comfort
  • Adjustable waist straps – for a close fit

➡ See full range of Arc Flash Clothing, PPE & Protection Garments 



Arc Flash Jacket Category 2 9.5 Cal

Arc Flash Jacket Order Code | ProGARM 5850

European Standards

ProGARM 5850 arc flash jacket conform to the following European Standards:

  • EN ISO 11611:2015 | Class 1 | A1
  • EN ISO 11612:2015 | A1 | B1 | C1
  • EN 1149-5:2008 | Pt. 5:2008 | Pt. 3:2004 | Charge Decay
  • IEC 61482-2:2009 | Class 1 | EBT50 = 9.5cal/cm² | ARC 2

Jacket | Care Information

ProGARM 5850 arc flash jacket must be carefully cleaned to ensure arc flash protection levels are maintained.

  • Do not bleach, boil or use soap based products – clean polo shirts using detergents only
  • Dirty clothing may lead to reduction in arc flash protection
  • Company will not accept liability for garments where care labels have been ignored, neglected, defaced or removed
  • Always store arc flash clothing in clean dry conditions
  • Do not store in places subject to direct strong sunlight

Arc Flash Jacket Size Chart

UK Size XS S M L XL 2XL 3XL 4XL 5XL
EU Size 44-46 48-50 52-54 56-58 60-62 64-66 68-70 72-74 76-78
CHEST (INCH) 43.3 44.9 48.8 52.8 56.7 60.6 64.6 68.5 72.4
CHEST TO FIT (INCH) 34-36 36-38 38-41 41-44 44-46 46-50 50-52 52-56 56-58
CHEST (CM) 110.0 114.0 124.0 134.0 144.0 154.0 164.0 174.0 184.0
CHEST TO FIT (CM) 85-90 90-95 95-102.5 102.5-110 110-115 115-125 125-130 130-140 140-145

Related Arc Flash Clothing Protection & Products​

IEC 61482 PROTECTIVE CLOTHING AGAINST THE THERMAL HAZARDS OF AN ELECTRIC ARC

Arc flash clothing and garments in a layered combination deliver workwear protection against hazards according to IEC 61482 – PPE protects the worker against electric arc flash dangers. According to IEC 61482-1-1:2009 (encompassing NFPA 70E 2015) the 4 arc risk categories are numbered according to the severity threat and determine the clothing protection level required to protect against a minimum level of incident energy measured in calories / cm² – this is the ‘Open Arc’ test method and measures clothing protection level according to the Arc Thermal Performance Value (ATPV).

NFPA 70E outlines the requirements for safe work practices to protect personnel by reducing exposure to workplace electrical hazards.

The ‘Box Arc’ tests clothing materials and fabric according to a pass/fail test by exposure to electric arc produced by 4kA (Class 1) and 7kA (Class 2) short circuits – this is IEC 61482-1-2:2009.

ARC 1 4 Cal ♦ ARC 2 8 Cal ♦ ARC 3 25 Cal ARC 4 40 Cal 

IEC Standard 61482 – Class 1

Garment Category – Jacket

Order Code – ProGARM 5850

  • Anti Static BS EN 1149-5:2008 Electrostatic Properties Of Protective Clothing
  • Flame Resistant EN ISO 11612:2015 Protective Clothing Against Heat & Flame

Arc Flash Category 2 Jacket 9.5 Cal

Arc Flash Class 1 Polo Shirt

arc flash protection product range

Electrical PPE Products | Gloves | Arc Flash Clothing | Arc Suits | Coveralls | Helmets & Visors

Arc Flash

Safety Wear & Arc Flash Protection | Thorne & Derrick understand how critical it is to have reliable, highest quality personal protection equipment (PPE), clothing and workwear available from stock at competitive prices – protecting utility workers against arc flash dangers posed during maintenance on underground electric cables, overhead line conductors or electrical equipment.