Voltage Detectors 1500V DC | 3000V DC – Pfisterer KP-Test 5R DC Dual

Voltage Detectors 1500V DC 3000V DC
Voltage Detectors
Pfisterer KP-Test 5R DC Dual is a double-pole voltage detector is similar in design to the KP-Test 5R DC for use on catenary systems of DC voltage railways. However in addition this voltage detector can be switched between two nominal voltage ranges in two steps. This allows a larger system range to be covered even when there is a high proportion of leakage current.
The KP-Test 5R DC dual has two selectable voltage steps.
Step 1:
- Voltage 50 V DC
- Selected by briefly pressing the On button
- LED indicator: 1 x green
Step 2:
- Voltage 1,500 V DC
- Selected by pressing and holding the On button
- LED indicator: 2 x green
The KP-Test 5R DC Dual ensures maximum user safety thanks to its extensive and integrated self-tests and displays safe, clear instructions.
Other versions of the voltage detector for rail power systems with deviating voltages, ranges of nominal voltages, frequencies and languages are available on request.
Voltage Detector
Technical Specification
- Double-pole type for the catenary systems of d.c. voltage railways with nominal voltages from 500 to 4,000 V DC
- Second pole designed for handy magnetic connection to rail
- Voltage range selection
- Hook-type contact electrode with high-quality contact pin for optimum contact
- Self-test at switch-on also checks the connecting cable
- Can be used during precipitation
- Integrated audible signal for reliable voltage tests even in noisy ambient conditions
- Extremely strong LEDs in clear layout to prevent confusion
- Induced a.c. voltage signal detection
- Voltage testing possible even with a high proportion of leakage current on disconnected contact wires
- Available separately without insulating pole
- Available separately without insulating pole, but with additional adapter
- Available complete with three-piece insulating pole (poles RP1 and UP; total length about 5,000 mm), or five-piece insulating pole (poles RP2, RP3, RP4 and UP; total length about 4,880 mm)
- Available with convenient carrying case
âž¡ See also – Voltage Detectors Medium Voltage
                      Voltage Detectors High Voltage
♦ When using voltage detectors to establish presence of operating voltages on MV-HV power cables or overhead lines there may be a requirement to apply field equipment earths, portable earthing, to equipment which is working adjacent to Live conductors to discharge any induced voltages.
Pfisterer KP-Test 5R DC Dual
Voltage Detector Technical Specification
| Pfisterer Part Number | Nominal Voltage Level I DC Un (V) | Nominal Voltage Level I DC Un (V) | Â Transporting Length LIÂ (mm) | Number of Insulating Poles | Suitable Bag |
| 930 350 501 0007 | 600 | 1200 | 1111 | – | B1 |
| 930 350 501 0008 | 600 | 1200 | 2450 | 2 | B3 |
| 930 350 501 0009 | 600 | 1200 | 1111 | 4 | B1 |
| 930 350 501 0010 | 750 | 1500 | 1111 | – | B1 |
| 930 350 501 0011 | 750 | 1500 | 2450 | 2 | B3 |
| 930 350 501 0012 | 750 | 1500 | 1111 | 4 | B1 |

Voltage Detectors | Phase Comparators | Operating Poles | Earthing Poles | Earthing & Short Circuiting

CONNEX | Cable Joints | Terminations | Connectors | Bushings | Surge Arresters for MV HV Medium & High Voltages | Pfisterer