6.6kV 7.2kV Cable Termination Kits Single Core 630-1000sqmm SPS 1TES-7.2X-E
6.6kV cable termination kits using heat shrink technology are suitable for terminating medium/high voltage (MV-HV) single core polymeric cables (XLPE EPR) – this includes cables with copper wire/tape screen and armoured (wire armoured/braided) or unarmoured cable for outdoor termination of 6.6kV cables, indoor version available.
SPS 1TES-7.2X-E cable termination kit suits 6.6kV 7.2kV cables with 630sqmm, 800sqmm, 1000sqmm single core conductors.
6.6kV 7.2kV xlpe epr Cable Termination
HV High Voltage – Outdoor
- Cable Termination Type – Heat Shrink
- Termination Location – Outdoor (Pole Top, Overhead Line)
- Number of Cores – Single Core
- Conductors – 630sqmm, 800sqmm, 1000sqmm
- Cable Type – XLPE EPR (Polymeric)
- Heat Shrink Standard Tail Length – 400mm
- Termination Kit Order Code – SPS 1TES-7.2X-E
- Suit MV HV Power Cables – BS6622, BS7835, BS7870, BS6883, BS7917 & IEC60502-2
Terminating HV Cables Outdoor
When terminating MV HV cables in outdoor locations anti-track heat shrink rain sheds should be installed from the bottom of the cable termination according to the jointing instructions issued with the kit – number of rain sheds depends on whether power cable is 6.6kV, 11kV, 33kV or other.
The cable jointer should avoid positioning the sheds at the top of the stress control tubes – the initial heat shrink rain shed should be fitted at a distance of 200mm from the lower edge of the anti-track tube to the edge of the heat shrink shed.
Reverse MV HV Connection
If the heat shrink terminations are to be mounted for connection above the switchgear or transformer in an outdoor location substation the heat shrink sheds should be installed in the reverse position rotated through 180 degrees – consult the termination kit instructions.
Overhead Lines
T&D accessories for medium/high voltage overhead line installations and maintenance include portable earthing, insulators, tension and suspension clamps, arc flash protection, current limiting devices, connectors, bird protectors, conductor cutting and crimping tools.
➡ High Voltage Cable Termination 6.6kV Kit List
➡ 6.6kV Cable Terminations | 3 Core Indoor XLPE | 3 Core Outdoor XLPE | 11kV 33kV Terminations
Single Core XLPE 7.2kV outdoor Terminations
6.6kV 7.2kV Cable Termination Kits
The following enables the termination kit selection for 6.6kV single core outdoor cables:
6.6kV/7.2kV Cable Termination Indoor | Cable Termination Kit Range | 6.6kV/7.2kV Cable Termination Outdoor |
1TIS-7.2X-A | 25-50sqmm | 1TES-7.2X-A |
1TIS-7.2X-B | 70-185sqmm | 1TES-7.2X-B |
1TIS-7.2X-C | 240-300sqmm | 1TES-7.2X-C |
1TIS-7.2X-D | 400-500sqmm | 1TES-7.2X-D |
1TIS-7.2X-E | 630-1000sqmm | 1TES-7.2X-E |