6.6kV 7.2kV Cable Termination Kits Single Core 630-1000sqmm SPS 1TES-7.2X-E

Cable Termination Cable Joints - Heat Shrink MV HV

6.6kV cable termination kits using heat shrink technology are suitable for terminating medium/high voltage (MV-HV) single core polymeric cables (XLPE EPR)  – this includes cables with copper wire/tape screen and armoured (wire armoured/braided) or unarmoured cable for outdoor termination of 6.6kV cables, indoor version available.

SPS 1TES-7.2X-E cable termination kit suits 6.6kV 7.2kV cables with 630sqmm, 800sqmm, 1000sqmm single core conductors.

6.6kV 7.2kV xlpe epr Cable Termination

HV High Voltage – Outdoor

  • Cable Termination Type – Heat Shrink
  • Termination Location – Outdoor (Pole Top, Overhead Line)
  • Number of Cores – Single Core
  • Conductors – 630sqmm, 800sqmm, 1000sqmm
  • Cable Type – XLPE EPR (Polymeric)
  • Heat Shrink Standard Tail Length – 400mm
  • Termination Kit Order Code – SPS 1TES-7.2X-E
  • Suit MV HV Power Cables – BS6622, BS7835, BS7870, BS6883, BS7917 & IEC60502-2

Terminating HV Cables Outdoor

When terminating MV HV cables in outdoor locations anti-track heat shrink rain sheds should be installed from the bottom of the cable termination according to the jointing instructions issued with the kit – number of rain sheds depends on whether power cable is 6.6kV, 11kV, 33kV or other.

The cable jointer should avoid positioning the sheds at the top of the stress control tubes – the initial heat shrink rain shed should be fitted at a distance of 200mm from the lower edge of the anti-track tube to the edge of the heat shrink shed.

Reverse MV HV Connection

If the heat shrink terminations are to be mounted for connection above the switchgear or transformer in an outdoor location substation the heat shrink sheds should be installed in the reverse position rotated through 180 degrees – consult the termination kit instructions.

Cable Terminations

Complete range of Cable Duct and Duct Seals available for MV HV cable installations

Overhead Lines

T&D accessories for medium/high voltage overhead line installations and maintenance include portable earthing, insulators, tension and suspension clamps, arc flash protection, current limiting devices, connectors, bird protectors, conductor cutting and crimping tools.

Overhead Line Equipment

See Thorne & Derrick full range of Overhead Line Equipment | Cutting Tools | Crimping Tools | Insulators | Electrical Safety

➡ High Voltage Cable Termination 6.6kV Kit List

6.6kV Cable Terminations | 3 Core Indoor XLPE | 3 Core Outdoor XLPE | 11kV 33kV Terminations

Cable Terminations Outdoor High Voltage 11kV 33kV

Outdoor located heat shrink pole-top type cable terminations include anti-track rain sheds to increase creepage distances for 6.6kV 11kV 33kV cable end connections

Single Core XLPE 7.2kV outdoor Terminations

6.6kV 7.2kV Cable Termination Kits

The following enables the termination kit selection for 6.6kV single core outdoor cables:

 6.6kV/7.2kV Cable Termination Indoor  Cable Termination Kit Range 6.6kV/7.2kV Cable Termination Outdoor 
1TIS-7.2X-A 25-50sqmm 1TES-7.2X-A
1TIS-7.2X-B 70-185sqmm 1TES-7.2X-B
1TIS-7.2X-C 240-300sqmm 1TES-7.2X-C
1TIS-7.2X-D 400-500sqmm 1TES-7.2X-D
1TIS-7.2X-E 630-1000sqmm 1TES-7.2X-E
Heat Shrink Cable Terminations 6.6kV 11kV 33kV

Cable terminations using heat shrink technology for MV-HV (6.6kV 11kV 33kV) cable connection to switchgear, transformers, overhead line and pole-mounted – see also Heat Shrink HV Cable Joints

Data Sheets