Pfisterer KP-Test 5H is a capacitive voltage detector for nominal voltages from 25kV to 400kV. The voltage detector presents the operating voltage when brought into contact with the conductor.

The Pfisterer KP-Test 5H voltage detector provides a high level of user-friendliness and user safety – KP-Test 5H is designed and type tested to Standard IEC 61243-1.

Other versions of the HV high voltage detector with deviating voltages, ranges of nominal voltages, frequencies and languages are available on request.

KP-Test 5H instruments detect the following voltage classes: 25kV 33kV, 66kV, 110kV 132kV, 220kV, 400kV, 420kV.


Voltage Detector

Technical Specification

  • Detectors available for different ranges of nominal voltages from 25kV to 400kV
  • Can be used during precipitation – outdoor and overhead line voltage indication
  • Particularly loud, integrated audible signal for reliable voltage tests even in noisy ambient conditions
  • Extremely strong LEDs in clear layout to prevent confusion
  • Maximum interference field resistance through the use of a high-quality contact electrode extension
  • Extensive self-test functions at switch-on
  • Voltage detector available separately for use with existing insulating poles
  • Available complete with suitable insulating poles in any overall length or carrying length
  • Insertion depth Ai = 898 mm

âž¡ See also – Voltage Detectors Medium Voltage

♦ When using voltage detectors to establish presence of operating voltages on MV-HV power cables or overhead lines there may be a requirement to apply field equipment earths, portable earthing, to equipment which is working adjacent to Live conductors to discharge any induced voltages.


Pfisterer KP-Test 5HL

Live Line Indicator | Network Rail Approved

For the use on Network Rail OLE & Isolation schemes the Pfisterer KP5, Module E14C, is Approved to NR/L3/ELP/27237 and PADS Certified.

Live Line Indicator Scope

This module covers the use and care of the Pfisterer KP-Test 5HL Live Line Indicator (LLI) – as detailed on product acceptance certificate PA05/06351. This LLT electrical safety device is used for checking 25kV AC electrical conductors before the application of portable earths and before touching conductors to reduce the likelihood of operators interacting with live conductors, therefore reducing the likelihood of damage to the infrastructure and serious injury to personnel.

Live Line Indicator Description

The KP-Test 5HL LLI is one of a number of approved Live Line Indicators LLIs that may be used to test the 25kV conductors to confirm that it has been disconnected from the source of supply prior to attaching earths (test before earth) or testing before touching.

KP-Test 5HL LLI Method of Use 

The KP-Test 5HL LLI shall only be used by personnel holding a valid competency (i.e. Authorised Person or Nominated Person) who shall have received a familiarisation briefing.

The KP-Test 5HL LLI shall only be applied to the lowest conductor of those being tested, i.e. contact wire or bottom autotransformer feeder (ATF) only. The KP-Test 5HL LLI shall only be attached to approved live line poles.

KP5 Pfisterer Live Line Tester

KP5 Pfisterer Live Line Tester

Thorne & Derrick supply an extensive range of 400V-66kV Rail Cable Accessories & Electrical Equipment to contractors undertaking Low Voltage Power Distribution, HV Electrification & Substations, DC Traction & Networks, OLE and Track Feeder Cable Renewals – a complete range of Network Rail PADS approved medium voltage cable terminations, joints, cable repair and connection products up to 66kV.

Thorne & Derrick supply an extensive range of 400V-66kV Rail Cable Accessories & Electrical Equipment to contractors undertaking Low Voltage Power Distribution, HV Electrification & Substations, DC Traction & Networks, OLE and Track Feeder Cable Renewals – a complete range of Network Rail PADS approved medium voltage cable terminations, joints, cable repair and connection products up to 66kV.

âž¡ See also – Voltage Detectors Medium Voltage

♦ When using voltage detectors to establish presence of operating voltages on MV-HV power cables or overhead lines there may be a requirement to apply field equipment earths, portable earthing, to equipment which is working adjacent to Live conductors to discharge any induced voltages.Contact Thorne & Derrick for technical support and advice on a complete range of Live Line Testers for medium/high voltage underground cable and overhead line power systems.


 

Voltage detectors in the KP-Test 5H range provide dual indication of voltage i) Audible Signal ii) Visual Indication:

Voltage Detectors 1

Voltage Detectors | MV HV | Switchgear Substations Overhead Lines Up To 33kV

Voltage Detectors 2

Pfisterer KP-Test 5H Voltage Detector - Dimensions

Pfisterer KP-Test 5H Voltage Detector – Dimensions


Pfisterer KP-Test 5H

Voltage Detector Technical Specification

Pfisterer Part Number Nominal Voltage Un (kV) Insulating Length LI (mm) Total Length LG (mm)  Transporting Length LI (mm) Number of Insulating Poles
930 250 001 0028 30 – 60 kV / 50 Hz 975 2478 1485 1
930 250 001 0003 50 – 110 kV / 50 Hz 1802 3700 1855 2
930 250 001 0089 60 – 110 kV / 50 Hz 2875 4773 2050 2
930 250 001 0115 110 kV / 50 Hz 1802 3700 1855 2
930 250 001 0002 110 – 220 kV / 50 Hz 3220 5118 2050 3
930 250 001 0023 220 – 380 kV / 50 Hz 3850 5748 2050 3
930 250 001 0024 220 – 420 kV / 50 Hz 3850 5748 2050 3
930 250 001 002 400 kV / 50 Hz 3850 5748 2050 3