Blog
130kV EHV XLPE Cable Pencilled Using Hivotec Peeling Tool
January 23rd, 2020Image: Fredrik Pedersen – HV Cable Jointer / Supervisor | Installation Technician på Scandinavia Power Crew AB
Pictured: 130kV EHV XLPE Cable Pencilled Using Hivotec Peeling Tool

NKT Cable Joints & Cable Terminations Overview
• Self-supporting outdoor cable terminations, porcelain or composite
• Non-self-supporting outdoor cable terminations, silicone
• Cable terminations for gas-insulated switchgears (GIS)
• Transformer terminations
• Straight-through cable joints
• Insulating joints/cross-bonding cable joints
• Transition cable joints, XLPE-insulated/oil-filled cables
• NKT CabSnap® accessories for preassembled cable connection systems

Jointers blog
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.
PFISTERER TENSOREX C+ | The Patented Spring Automatic Tensioning System for Rail Systems
January 23rd, 2020
PFISTERER TENSOREX C+
PFISTERER TENSOREX C+
Automatic Tensioning System for Rail Systems
-
uploaded by Chris Dodds | Thorne & Derrick Sales & Marketing Manager
PFISTERER TENSOREX C+ is an automatic tensioning system that uses the force of a coil spring to constantly tension the railway catenary and/or bearer cable.
The TENSOREX C+ is a patented spring automatic tensioning system which has been installed on many worldwide prestigious rail and tramway systems. It therefore effectively compensates the expansion caused by fluctuating daytime and night-time temperatures as well as the change in the seasons while keeping the tension at a constant level.
Applications
- For railways and tramways
- Best solution for portals, tunnels and platforms
- Inner-city installations where low visual impact is requested
Facts
- Units Sold: 14,000+ (Asia, Africa, Australasia, Europe, North and South America)
- Compensating Length: 450-1100 mm
- Line Tension Force: 7.5-40 kN

PFISTERER TENSOREX C+
PFISTERER TENSOREX C+ Advantages:
Highest reliability:
Every TENSOREX C+ unit is tested before shipping to the customer
Compact design:
Easy handling and transportation
Esthetical solution for inner-city installations
Fast installation
Delivered ready to install, no assembly required, no weights have to be installed
No tensioning weights required:
Vandal resistant
Free space on the mast base – escape routes are not blocked
Maintenance-free
High precision
Constant tightening force over the entire regulation range
Fast and precise response – very small traction force hysteresis
Purely mechanical system
Requires no additional power supply. No influences due to temperature changes
Reduced risk of vandalism / theft
Low impact aesthetics
Suitable for tunnels / areas of limited space
Mounting solutions available for all applications
Reusable in the event of wire failures
How it Works
By means of a support cable, TENSOREX C+ exerts a constant tension on the contact wire, regardless of any changes in length due to temperature. The special spiral spring is firmly connected to two cams on the same shaft. The degree of rotation of the shaft results in a linear variable torque/moment, which is compensated for by the combination with the variable radius of the cam.
This produces a constant pulling force over the entire device working range.

PFISTERER TENSOREX C+ | How it works?
FContact wire = f (M/r) = const.
FContact wire >> Force on contact line
MSpring >> Torque/moment applied by spring (variable on linear basis)
rPulley >> Radius of cam (variable)
lWork >> Device working range correspond to variable pulley profile length
PFISTERER TENSOREX C+ Technical Data
| Pfisterer Part Number | N/A | 000 700 439 |
|---|---|---|
| Pull force | (kg) | 1200 |
| Pull force | (kN) | 11.8 |
| Compensating length | (mm) | 750 |
| Spring quantity | N/A | 3 |
| Weight | (kg) | 150 |
| Width | (mm) | 429 |

PFISTERER TENSOREX C+- Automatic Tensioning System for Rail Systems
THORNE & DERRICK
Thorne & Derrick are national distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment – servicing businesses involved in cabling, jointing, substation, earthing, overhead line and electrical construction at LV, 11kV, 33kV, 66kV and EHV. Supplying a complete range of power cable accessories to support the installation and maintenance of low/medium and high voltage cable systems:
- Slip-on Cable Terminations
- Cold-shrink Cable Terminations
- Heat-shrink Cable Terminations
- Cable Joints – Heat & Cold-shrink
- Separable Connectors (Euromold)
- Surge Arresters & Switchgear/Transformer Bushings
Key Product Categories: Duct Seals | Cable Cleats | Cable Glands | Electrical Safety | Arc Flash Protection | Cable Jointing Tools | Cable Pulling | Earthing | Feeder Pillars | Cable Joints LV | Joints & Terminations MV

IEC 61482-2 2018 – Get Up To Speed With The New Arc Flash Standard
January 23rd, 2020
Arc Flash Protection
IEC 61482-2:2018
Article Courtesy of ProGARM Arc Flash Protection & Clothing
A new test standard for arc flash protection – IEC 61482-1-1:2018 – was introduced in May 2019, which means arc flash protective garments certified after May 2019 have to be tested under these new, more stringent conditions under the PPE regulation.
This is a result of the updates to the Arc Flash standard for garments, IEC 61482-2:2018, which was released in 2018.

This standard is significantly different to FR standard EN ISO 11612. It includes more rigorous and different requirements, and is the standard for garments to protect those at risk of Arc Flash. The latest update to the standard was in 2018 and contained a couple of important changes to the test methods with regards to the performance ratings of garments.
The new test results in a new way of rating arc flash clothing, ELIM (Energy Incident Limit), which will be used as a further arc rating performance property value and as a more stringent performance indicator of both fabric and garments.
♦ IEC 61482-1-1:2019 Live Working – Protective clothing against the thermal hazards of an electric arc – Part 1-1: Test methods – Method 1: Determination of the arc rating (ELIM, ATPV and/or EBT) of clothing materials and of protective clothing using an open arc.

ProGARM | Functional Arc Flash Clothing, Protection & PPE For Everyday Wear
As a result of this ProGARM have written a short guide to the new IEC 61482-2:2018 standard to highlight the key bits of information you need to be aware of when reviewing your PPE specification and the key terminology that you need to understand.
Choosing the right PPE for your team can be difficult and with all the standards to consider it can feel quite overwhelming. This guide aims to help people make a more informed decision about what PPE is best for you.
You can download the PDF guide via this link or see the attached pdf below.

Arc Flash Clothing | Polo Shirts | Jackets | Coveralls | Trousers | Sweatshirts | Helmets
With the recent changes to the IEC 61482-2 standard, ProGARM outline the key changes and unpack the details to help you understand the important information that impacts you.
SCOPE
Learn about what this standard covers and why it’s important to have an understanding of it when working with or near live electricity.
TEST METHODS
Understand the two test methods used within this standard and how they contribute to providing calorific and class values to identify the level of protection different products provide.
CALORIFIC VALUES EXPLAINED
ATPV, EBT50, ELIM. What’s the difference?
We explain the differences between each calorific value, how they are calculated and what to look for when specifying PPE for your team.
PROGARM, THE ARC FLASH SPECIALISTS
ProGARM are a the leading UK manufacturer of high quality Flame Resistant & Arc Flash Clothing, garments and workwear – they work successfully with their UK Distributor Thorne & Derrick to save lives and reduce accidents.

Thorne & Derrick are proud to be distributors of ProGARM arc flash clothing and protection.
We can help – should you require arc flash calculators or advice on the type of clothing and protection available please do not hesitate to contact us.
Further Reading
- Arc Flash Clothing – PPE To Protect Highways, Street Lighting & Utility Contractors
- Arc Gloves | New Arc Flash Dexterity Gloves from Protection Specialists ProGARM
- New Arc Flash Coveralls from Protection Specialists ProGARM
THORNE & DERRICK
Thorne & Derrick are national distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment – servicing businesses involved in cabling, jointing, substation, earthing, overhead line and electrical construction at LV, 11kV, 33kV, 66kV and EHV. Supplying a complete range of power cable accessories to support the installation and maintenance of low/medium and high voltage power systems:
- Slip-on Cable Terminations
- Cold-shrink Cable Terminations
- Heat-shrink Cable Terminations
- Cable Joints – Heat & Cold-shrink
- Separable Connectors (Euromold)
- Surge Arresters & Switchgear/Transformer Bushings
Key Product Categories: Duct Seals | Cable Cleats | Cable Glands | Electrical Safety | Arc Flash Protection | Cable Jointing Tools | Cable Pulling | Earthing | Feeder Pillars | Cable Joints LV | Joints & Terminations MV
Arc Flash Learning & Resources

Thorne and Derrick are proud to be distributors of ProGARM arc flash coveralls and protection.
We can help – should you require arc flash calculators or advice on the type of clothing and protection available please do not hesitate to contact us.

110kV Oil Filled Taihan High Voltage Cable Joints
January 22nd, 2020Pictured below : 110kV Oil-Filled 800sqmm BICC Cable To 1000sqmm Taihan Cable Using Taihan EHV Cable Joints.
HV Cable Jointer : Andrew Brezovszky (EHV Cable Jointer at Energex Australia).
Taihan develop and manufacture the highest-quality products in the power, communications and materials industries.


Cable joint ready for outer protection boxes and encapsulating resin

Cable joint cases positioned. Saving some room for the next feeder

110kV Taihan Oil Joints – Bonding Leads Made Off

Taihan 110kV Oil Cable Joints
Pictured are 800sqmm cables “cut & cap” ready for cable jointing. The abandoned side will be recovered at a later stage hence the platforms.
Taihan – EHV Cable Joints & Cable Terminations
XLPE Cable Accessories
- Pre-Molded Joint Pre-Molded Joint (110kV – 161kV)
- Pre-Molded Joint (220kV – 275kV)
- Pre-Molded Joint (330kV – 400kV)
- Outdoor Termination (EB-A)
- Outdoor Termination (110kV – 161kV)
- Outdoor Termination (220kV – 275kV)
- Outdoor Termination (330kV – 400kV)
- SF6 Gas Insulated Termination (EB-G)
- SF6 Gas Insulated Termination (110kV – 161kV)
- SF6 Gas Insulated Termination (220kV – 275kV)
- SF6 Gas Insulated Termination (330kV – 400kV)
- Oil-Filled (O.F) Cable Accessories
Taihan high voltage transition joint is applicable for jointing single core oil-filled (O.F) cable to single core XLPE cable. The 3-core oil-filled cable can be connected by using a splitter box (trifurcating joint box). The prefabricated and dry (oil-less) configuration is used on the XLPE cable side while on the oil-filled cable side conventional oil impregnated paper roll and newly adopted epoxy bell mouth is applied to complete the compact cable joint design.
Pictured: EHV High Voltage Transition Joint

Jointers blog
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.
Installing Bank Of Medium Voltage Westinghouse Regulators To Overhead Line
January 22nd, 2020Image Courtesy of: Ricardo Heron (Utilities Professional)
Pictured: Installing Bank Of Medium Voltage Westinghouse Regulators To Overhead Line


Jointers blog
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.