CATU CZ-55-RM MV HV 33kV / 36kV Substation Life Saving Kits (Wall Mounted)

CATU CZ-55-RM MV HV 33kV / 36kV Substation Life Saving Kits (Wall Mounted)

CATU CZ-55-RM MV HV 33kV / 36kV Substation Life Saving Kits (Wall Mounted)

CATU CZ-55-RM

CATU CZ-55-RM is a wall mounted substation life saving kit that can be used in the event of an electrical incident or accident in MV-HV substations – suitable for electrical intervention in 33kV and 36kV substations.

Typically wall mounted for electrical intervention in 33kV/36kV high voltage substations the CATU CZ55MR life saving electrical safety equipment manufactured by CATU Electrical is for use in assisting victims in the event of an electrical hazard or electrocution.

  • Manufacturer: CATU Electrical
  • Order Code: CZ-55-RM

CATU CZ-55-RM Kit

Life Saving Kits

The CATU Electrical CZ-55-RM electrical safety kit comprises the following contents:

  • Insulated cable cutter – steel blades with a maximum opening of 30mm (CATU CZ-60)
  • Wall mounted cabinet
  • Pair of insulating boots (CATU MV-137-45)
  • Voltage detector with flexible antenna contact (with autotest)
  • Telescopic rescue stick or pole up to 45kV (CATU M952170)
  • Safety instructions on plastic board
  • High voltage insulating gloves, insulating boots and talcum powder can
  • Insulating platform 24kV or 36kV (CATU CT-7-25/1)
  • Instructions in English & Arabic
  • See portable version CATU CZ-53-R 

CATU CZ55RM include class 4 insulating gloves suitable for 33kV/36kV safe working.

Life saving kits are available also for 33kV high voltage substations – this includes portable version CATU CZ-53-R/2 and CATU CZ-55-R wall mounted type for 33/36kV substations. The CATU CZ-55-RM product is stocked in the UK by Thorne & Derrick.

CATU CZ-55-RM MV HV 33kV / 36kV Substation Life Saving Kit (Wall Mounted)

CATU CZ-55-RM MV HV 33kV / 36kV – the wall mounted cabinet features transparent doors for clear visual access to electrical safety equipment in an emergency

CATU CZ55RM

MV HV 33kV 36kV sUBSTATIONS

  • Part Number – CATU Electrical CZ55RM
  • Voltage – 33kV 36kV
  • Dimensions – 840mm x 754mm x 270mm
  • Weight – 21kg
  • Call T&D To Discuss 11kV 33kV Substation Equipment

Warning

  • For optimum electrical protection all MV HV insulating components should be used (stool, gloves, pole)
  • The 33kV voltage detector only works with AC power (no voltage detection is possible when using MV HV type DC installations)
  • Always check the substation equipment integrity and condition prior to use, especially insulating gloves
  • Before and after checking to ensure that no MV HV voltage is present, always check current installation operation
  • The above safety check should be performed in contact with bare conductive parts
  • Never cut a number of cable phases at the same time using the insulated cable cutters

➡ An overview of the full range of CATU Substation Life Saving Kits:

CATU Order Code Products Description Maximum Voltage Physical Dimensions Weight
CZ-53-R Portable Life Saving Kit | English Instructions 25kV 710mm x 510mm x 240mm 21kg
CZ-53-MR Portable Life Saving Kit | English / Arabic Instructions 25kV 710mm x 510mm x 240mm 21kg
CZ-53-R/2 Portable Life Saving Kit | English Instructions 36kV 710mm x 510mm x 240mm 21kg
CZ-53-MR/2 Portable Life Saving Kit | English / Arabic Instructions 36kV 710mm x 510mm x 240mm 21kg
CZ-54-RM Wall Mounted Life Saving Kit | English / Arabic Instructions 24kV 840mm x 754mm x 270mm 21kg
CZ-55-R Wall Mounted Life Saving Kit | English Instructions 36kV 840mm x 754mm x 270mm 21kg
CZ-55-RM Wall Mounted Life Saving Kit | English / Arabic Instructions 36kV 840mm x 754mm x 270mm 21kg

Installing CATU CZ55RM

To facilitate wall mounting of CATU CZ55 kits it is recommended to initially empty the cabinet of all components.

Mount the angle brackets on the wall of the high voltage substation taking care to match the precise distance of 600mm between brackets (using two screws per bracket).

CATU CZ55RPlace the cabinet onto the angle brackets and clip the two pressure mounted plastic clips into place.

CATU CZ55R

With the CATU CZ55 cabinet still on the wall drill the wall through the two holes located in the base of the cabinet – press the wall plugs in and screw in the two screws after inserting the washers.

CATU CZ55R

Stow the electrical safety component parts in the cabinet using the Velcro strips for boots, cable cutter and stool. Extend the insulating pole and mount the voltage detector. Clip the pole into the location provided. Check that the detector operates properly (press the red button for test purposes) – for specialist technical support on electrical safety when working in 33kV/36kV substations please contact us.

Arc Flash Clothing Protection

For the protection of workers against arc flash risks involved in LV MV HV switchgear testing, circuit breaker racking and carrying out electrical maintenance on cables, panels and switchboards please see Arc Flash Clothing & Protection.

MV HV Substation Electrical Equipment

T&D supply an extensive range of Medium & High Voltage Electrical Equipment to enable the transmission and distribution of 11kV, 33kV and 66kV – this includes cold shrink, heat shrink, push-on and plug-in cable joints and terminations used to connect MV-HV cables to switchgear and transformers. T&D stock the full range of CATU Electrical Safety Equipment including insulating gloves, voltage detectors, portable earth kits and arc flash protection for medium and high voltage electrical protection.

MV HV Medium High Voltage Substations 11kV 33kV

T&D – Suppliers Of Substation Safety & Electrical Equipment MV HV