Interface E – Nexans Euromold Connectors, Plugs, Elbows, Bushings & Surge Arresters
Nexans Euromold Interface E separable connectors for terminating MV-HV cables (including XLPE EPR 11kV 17.5kV, 24kV) – a complete range of tee connectors for termination of medium/high voltage cables into switchgear, transformers, motors and substations up to 42kV.
Full supporting range of Euromold tee 33kV connectors and bushings suitable for Interface E bushings according to CENELEC EN 50180 and 50181.
Euromold Interface E connectors are suitable for termination of polymeric (XLPE EPR) insulated cables with copper wire or tape screen, wire armoured (SWA/AWA), wire braided or unarmoured cables into MV-HV Electrical Equipment with Interface E bushings.
- 6/10kV (12kV)
- 6.35/11kV (12kV)
- 8.7/15kV (17.5kV)
- 12/20kV (24kV)
- 12.7/22 (24kV)
- 18/30 (36kV)
- 19/33 (36kV)
- 20.8/36 (42kV)
- Up to 42kV 800 Amps
➡ Blog: Euromold 700 Series Connectors | Interface E Bushings | Nexans Euromold
Interface E Connectors & MV HV Euromold Products
- Euromold 784TB Tee Connector
- Euromold 750S1, 775S1 & 775T1 Bushings
33kV Connectors Interface E
Short Circuit Ratings
E1
- Contact Type – Bolted
- Connector Current Rating – 800A
- RMS Symm
1 Sec – 50.0kA
2 Sec – 35.3kA
3 Sec – 28.8kA - Peak Asymm – 125kA
- Cable Connector Voltage Um – 36kV
E2
- Contact Type – Bolted
- Connector Current Rating – 1250A
- RMS Symm
1 Sec – 75.0kA
2 Sec – 53.0kA
3 Sec – 43.3kA - Peak Asymm – >150kA
- Cable Connector Voltage Um – 36kV
Euromold 784TB Tee Connectors Up to 24kV 800A
Euromold Separable Connector Type |
Voltage Um (kV) |
Current Ir (A) Aluminium/ Copper | Conductor Sizes (sqmm) | |
min | max | |||
784TB/G | 11kV | 800/1250 Amps | 50 | 630 |
K784TB/G | 24kV | 800/1250 Amps | 35 | 630 |
M784TB/G | 36kV | 800/1250 Amps | 35 | 630 |
P784TB/G | 42kV | 800/1250 Amps | 35 | 630 |
Euromold 784TB Ordering Instructions
Select the Nexans Euromold connector part number from the below table which provides the best centring of your core insulation diameter and substitute X according to your conductor size and type. For 24kV connectors add a “K”, for 33kV/36kV connectors add a “M” and for 42kV add a “P”.
Euromold Connector Order Example – the MV-HV cable to be terminated is XLPE insulation 36kV with 240sqmm stranded aluminium with a diameter over core insulation of 37.0mm. Order Code: 3 x Euromold M784TB/G-S-32-240AL2.
Euromold 784TB Part Number | Dia. over core insulation (mm) | |
min | max | |
3 x 784TB/G-S-15-X | 16.0 | 22.0 |
3 x 784TB/G-S-19-X | 20.0 | 26.5 |
3 x 784TB/G-S-22-X | 23.5 | 31.0 |
3 x 784TB/G-S-27-X | 28.5 | 37.5 |
3 x 784TB/G-S-32-X | 34.0 | 42.5 |
3 x 784TB/G-S-37-X | 39.0 | 48.5 |
3 x 784TB/G-S-43-X | 45.5 | 56.0 |
Connectors Suitable For Copper & Aluminium Cables
Conductor sizes (sqmm) |
Aluminium Conductor | Aluminium & Copper Conductor | Copper Conductor | |
DIN Hexagonal Crimp | Deep Indent Crimp | Bolted | DIN Hexagonal Crimp | |
35sqmm | 35AL2 | 35AL1 | 16.95UN5 | 35UN2 |
50sqmm | 50AL2 | 50AL1 | 16.95UN5, 50.150UNS | 50UN2 |
70sqmm | 70AL2 | 70AL1 | 16.95UN5, 50.150UNS | 70UN2 |
95sqmm | 95AL2 | 95AL1 | 16.95UN5, 50.150UNS, 95.240UN5 | 95UN2 |
120sqmm | 120AL2 | 120AL1 | 50.150UNS, 95.240UN5, 120.300UN5 | 120UN2 |
150sqmm | 150AL2 | 150AL1 | 50.150UNS, 95.240UN5, 120.300UN5 | 150UN2 |
185sqmm | 185AL2 | 185AL1 | 95.240UN5, 120.300UN5, 185.400UN5 | 185UN2 |
240sqmm | 240AL2 | 240AL1 | 95.240UN5, 120.300UN5, 185.400UN5 | 240UN2 |
300sqmm | 300AL2 | 300AL1 | 120.300UN5, 185.400UN5 | 300UN2 |
400sqmm | 400AL2 | 400AL1 | 185.400UN5, 400.630UN5 | 400UN2 |
500sqmm | 500AL2 | 500AL1 | 400.630UN5 | 500UN2 |
630sqmm | 630AL2 | 630AL1 | 400.630UN5 | 630UN2 |
Interface E Bushing Connectors
Full supporting range of Euromold medium voltage accessories for use with Interface E connectors are available.
Nexans Euromold 750CP & 775CP Connecting Plug (800A 750CP, 1250A 775CP)
Plugs for connecting two or more connectors with a type E – 5/8″ Interface together and therefor creating a separable cable joint or a multiple cable connection to equipment.

750CP & 775CP Euromold
Nexans Euromold 750BE & 775BE Bushing Extender (800A 750BE, 1250A 775BE)
Bushing extender provides an extension piece to allow cable to stand away from equipment and is used in conjunction with the Euromold 750CP or 775CP.

750BE & 775BE Euromold
Nexans Euromold 750SOP Stand-Off Plug (800A, 1250A 750SOP)
Plug is designed to support “dead end” connectors with type E 5/8″ Interface when removed from MV-HV electrical equipment.

750SOP Euromold
Nexans Euromold 750GP Earthing Plug (800A, 1250A 750GP)
Plug is designed to support “dead end” connectors with type E 5/8″ Interface when removed from MV-HV electrical equipment.

750GP Euromold
➡ For further information on Euromold Connectors for all other Interface Bushings please see the following information:
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
HV Connectors manufactured by Nexans Euromold to suit Interface E bushings, 11kV-42kV. Call us to discuss your requirements for cable connectors, terminations and joints for 11kV-33kV high voltage power networks.

Interface E Bushings
➡ View the complete range of Nexans Euromold Connectors suitable for cable termination of 11kV, 33kV and up 66kV MV-HV cable.
11kV 33kV Heat Shrink Terminations | 33kV Cold Shrink Joints
➡ See the below product sections for the complete range of Nexans Euromold Connectors suitable for Interface E bushings on MV-HV equipment.

Euromold MV HV | Cable Terminations, Connectors, Elbows & Joints