Uploaded By Chris Dodds – Thorne & Derrick Sales & Marketing Manager
Why Use Cable Protection Covers?
Tape Tile & Stokbord
Centriforce Stokbord underground cable protection covers are manufactured from high impact, recycled polyethylene designed to withstand damage and protect medium/high voltage cables from plant and hand tools – the cable covers protect high voltage cables from damage caused by diggers and excavators inadvertently causing cable strikes when working around underground cables and utility services.
Both Tape Tile and Stokbord cable covers are used to protect LV-HV cables and cable ducts installed by the ‘open cut’ trench method – the cable protection products are intended, during any future excavation work, to give a clear visual warning of the presence of underground cable, cable joints or cable ducts. The cable identification is compliant with ENATS Standard 12-23 and meets the impact requirements of BS2484.
Pictured: High Voltage 11kV Cable Strike – an excavator has impacted onto a 11kV high voltage power cable penetrating the cable sheath and XLPE insulation to cause a power outage. Lack of planning on development projects increases the possibility of serious injuries to operatives and greatly increase cost to projects. On site cable records and use of cable fault locators should ensure worker safety and prevent accidental damage and strikes to high voltage cables.
Damage to underground cables can have serious repercussions such as damage to anyone working on or near the cables or a power blackout such as that experienced in Londonderry, December 2013.
LVLow Voltage | MV Medium Voltage | HV High Voltage Cable Protection
Why Use Stokbord?
Centriforce Stokbord cable covers are suitable for underground high voltage cable protection (22kV, 33kV, 66kV, 132kV and up to 400kV). The 4 thickness variations of Stokbord covers are 6, 9, 12 and 18mm. This coupled with the fact that Stokbord is easy to fabricate ensures Centriforce Stokbords are the ideal product for protecting underground cables.
Stokbord Cable Cover Application
Centriforce Stokbord Cable Covers are fully jointed, laid overlapped and connected with plastic jointing pegs to provide safe high voltage underground cable protection.
Centriforce Stokbord cable covers feature a red background with yellow top tape containing visible warning “Caution Electric Cable Below” – Stokbord cable covers meet BS2482 impact requirements for underground cable cover protection.
Not only does this protect from any impact to the cables that would be made by excavation, it also shows exactly where cables are laid. The locating of cables is therefore simplified.
The features and benefits of Centriforce Stokbord makes the performance of the products far superior to steel and concrete cable covers / tiles /plates.
Stokbord Cable Covers – Benefits At A Glance
Stokbord covers provide the clear warning to 3rd parties of underground buried cables
Cable covers can be custom made with sizes to suit medium/high voltage cable trenches
Contains bold warning text and company logo for clear MV-HV cable identification
Damages to cables reduced – cost of repairs, HV jointing and supply disruption reduced
Lightweight and easy to install Stokbord cable covers irrespective of weather conditions
Durable with good impact resistance for MV HV EHV cable protection
Rotproof and resistant to soil conditions for burial in underground cable trench
Plastic Cable Covers v Concrete Cable Covers
Cable Protection
Installation Of Cable Trench Covers & Cable Protection Tiles
All cables and ducts laid into cable trench should be over-protected by a cable protection cover or tape depending upon the highest voltage cable to be protected within the cable duct – typically in the UK the following cable protection tapes and covers are used for LV, MV and HV cables.
Marker tile tapes or Stokbord covers are installed over the cable in the appropriate trench drawings – usually there is no requirement to install either above approved cable ducts installed using trenchless techniques (i.e. directional drill) but either may be installed if it is deemed that additional MV-HV cable protection is required.
When Tape Tile is used it should be cut cleanly and installed so that the medium/high voltage cable is fully covered along the whole length of the installed cable duct.
Thorne & Derrick International distribute the most extensive range of Cable Pulling & Cable Laying Equipmentto enable the installation of low, medium and high voltage power cables into underground trench or duct – products also supplied for fibre optic blowing, subsea trenching, offshore umbilical installations and pulling armoured cables onto cable tray.
Contact us for 3M Electrical, ABB, Alroc, AN Wallis, CATU Electrical, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform, Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.
5 Common Cable Management Mistakes And How To Avoid Them Cable management is often overlooked but in industrial environments, it plays a critical role in safety, reliability and long-term performance. Loose, poorly routed or unprotected cables can quickly become...
Rethinking Cable Cleats for High-Density Data Centres Global demand for cloud computing, AI workloads and digital services is accelerating the construction of data centres at an unprecedented scale. Hyperscale facilities are now being developed across Europe, North America and...