11kV Cable Joints Single Core PILC Heat Shrink Straight Joint Kits

11kV Cable Joints Single Core PILC Heat Shrink Straight Joint Kits

Cable Joints 11kV | Single Core | PILC | Heat Shrink

Thorne & Derrick | Distributed from Stock | Approved Supplier | UK & Export Sales

HV cable joints are suitable for medium/high voltage (MV-HV) 11kV single core paper insulated cables (PILC) – cable joints use heat shrink tubes and suit 11kV cables with 50sqmm to 630sqmm single core conductors (copper and aluminium).


11kV Cable Joints

11kV heat shrink cable joints suit unarmoured and armoured PILC single core cables – this includes high voltage industrial power cables used for primary connections to HV switchgear, transformers or pole terminations.

  • PILC STA Paper Insulated Lead Covered Steel Tape Armoured
  • PILC SWA Paper Insulated Lead Covered Steel Wire Armoured

Cable joints can be modified to include armour continuity for aluminium wire armoured (AWA) cables – to order cable joints suitable for armoured cables use SPAJ part references.

Options include transition (PILC to XLPE) and transition trifurcating (3 x single core PILC to 3 Core XLPE) cable joints – contact us to discuss your requirements.

Cable Joints


The following enables the joint kit selection for 11kV single core cables:

SPS 11kV PILC Cable Joint – Order Code Cable Joint Kit Range – Single Core Cables
SPJ 12P-50-95-1 50-95sqmm
SPJ 12P-120-185-1 120-185sqmm
SPJ 12P-240-400-1 240-400sqmm
SPJ 12P-500-630-1

Use SPAJ order code for Armoured Cable Joints

500-630sqmm

 


11kV Joint Single Core PILC Cables

  • Cable Joint Type – Heat Shrink
  • Cable Voltage – 11kV
  • Number of Cores – Single Core
  • Conductors – 50sqmm, 70sqmm, 95sqmm, 120sqmm, 150sqmm, 185sqmm, 240sqmm, 300sqmm, 400sqmm, 500sqmm, 630sqmm
  • Cable Type – PILC
  • Suit MV HV 11kV Power Cables – BS6480
  • Also: 11kV Joint Single Core XLPE Cables

PILC Cables specification

  • Application: 11kV Paper Insulated Cable (PILC) is typically manufactured to British Standard BS6480/88 with flame propagation to BS EN 60332. The medium or high voltage power cable is primarily used on networks where additional protection is required from water, hydrocarbons and other contaminants.
  • Cable Conductor: Plain Annealed Copper Conductors
  • Cable Insulation: Paper Insulated
  • Bedding: Semi Conducting Carbon Paper Tape Bedding
  • Cable Armour: Galvanised Steel Wire Armour (SWA)
  • Cable Sheath: PVC
  • Sheath Colour: Red
  • Voltage Rating: 6350/11000 volts (11kV)
  • Operating Temperature: up to 65°C
11kV Cable Joints - PILC Single Core

Contact T&D for technical support and specification of 11kV PILC cable joints and terminations for single and 3 core cables.


Heat Shrink Cable Joints & Terminations

Complete range of medium and high voltage cable joints and terminations for XLPE & PILC single / 3 core cables:

➡ HV Cable Joints | HV Cable Terminations | 11kV Joints Single Core XLPE

➡ 11kV Joints 3 Core XLPE | 11kV Joints 3 Core PILC

MV HV Cable Terminations Cleats Tools

11kV Cable Installation Equipment | Cleats | Lugs | Glands | Earth Tapes | Substation Safety – leading manufacturers including Furse, CMP, Pfisterer, Prysmian, Alroc & Nexans Euromold


Heat Shrink Cable Joints

Test Technical Data

The following table provides an excerpt of data from the Type Test Reports for Heat Shrink Cable Joints for 6.6kV, 11kV and 33kV voltages.

Summary of Cable Joint Test Voltages
Test Test Voltage Rated Voltage U01U (Um) kV
3.8/6.6 (7.2) 6.35/11 (12) 8.7/15 (17.5) 12.7/22 (24) 19/33 (36)
Humidity & Salt Fog 1.25U0 5 8 11 16 24
Partial Discharge 1.73U0 6.5 11 15 22 33
2U0 7.5 12.5 17.5 25 38
Heating Cycle Voltage & AC Voltage / 15 min and 500 hours 2.5U0 9.5 16 23 32 47.5
AC Voltage / 1 min 4U0 15 25.5 35 51 76
AC Voltage / 5 min 4.5U0 17 28.5 39 57 85.5
DC Voltage / 15 min 6U0 23 38 52 76 114
Impulse (Peak) 60 95 95 125 194
Test Sequence & Requirements
Test Test Clause of EN 61442 Test Sequence Test Requirements
A1 A2 A3
1 DC Voltage Dry 5 X X 15 min at 6U0, no breakdown or flashover
2 AC Voltage Dry 4 X X 5 min at 4.5U0, no breakdown or flashover
3 Partial Discharge At Ambient Temperature 7 X Max 10pC at 1.73U0
4 Impulse Voltage At Elevated Temperature 6 X 10 impulses of each polarity, no breakdown or flashover
5 Heating Cycle Voltage In Air 9 X 126 cycles at 2.5U0, no breakdown or flashover for terminations and 63 cycles in air and 63 cycles in water for cable joints
6 Partial Discharge At Elevated & Ambient Temperature 7 X Max 10pC at 1.73U0
7 Thermal Short Circuit (Screen) 10 X 2 short circuits at 1sc no breakdown
8 Thermal Short Circuit (Conductor) 11 X 2 short circuits to raise conductor to 6sc of the cable, no breakdown
9 Dynamic Short Circuit 12 X 1 short circuit at 1d, no breakdown
10 Impulse Voltage At Ambient Temperature 6 X X 10 impulses of each polarity, no breakdown or flashover
11 AC Voltage Dry 4 X X 15 min at 2.5U0, no breakdown or flashover
12 Humidity 13 X 300 hours duration at 1.25U0
13 Examination X X X For information only

 


 