CATU MP-42/66 – MV Insulating Matting 26.5kV Class 3

CATU MP-42/66 – MV Insulating Matting 26.5kV Class 3

CATU MP-42/66 Matting

ELECTRICAL INSULATING MATTING

CATU MP-42/66 MV insulating matting is Class 3 approved with a maximum safe working voltage of 26500V  – the electrical insulating mats are used when operating switchboards, jointing cables, operating live switchgear, substations, transformers at medium voltage (MV). 

Class 3 matting protects workers against electrocution according to IEC 61111 up to 26,500 volts for MV medium voltage applications.

  • Insulating Mat Thickness – 3mm
  • Insulating Protection – Class 3
  • MV Medium Voltage Electrical Matting
  • Maximum Safe Working Voltage – 26500V Class 3
  • Large Matting Stocks | Competitive Prices | CATU MP-42/66

CATU Electrical MP-42/66 switchgear mats are manufactured from high quality dielectrical rubber with a regulatory mark clearly indicating the mat features.

Class 3 mats are available in widths including 1.2 metre, 1 metre and 0.6 metre –  electrical insulating matting rolls lengths are 0.6 metre, 1 metre, 5 metre and 10 metre.

Thorne & Derrick distribute Insulating Matting from extensive stocks to UK and Export customers in accordance with BS921IEC61111ASTM D178 and other international standards affecting the specification and selection of electrical safety matting for the use in control rooms, plant rooms, switchboards and substations energised at LV MV HV power systems.

Insulating Matting Mats

High-Quality Electrical Insulating Matting | insulating matting commonly referred to as dielectric or electrical safety matting is used to protect personnel and electrical equipment used in substation switchrooms, in front of energised switchboards, transformers and other low, medium and high voltage power systems.


CATU MP-42/66

MV Insulating Matting

26,500 Volts Class 3

  • Part Number – CATU Electrical MP-42/66
  • Minimum Voltage AC – ≤ 26500 Volts (26.5kV)
  • Maximum Voltage DC – ≤ 39750 Volts (39.7kV)
  • Insulation Category – Class 3 Medium Voltage
  • Matting Thickness – 3m
  • Dimensions – 0.6m x 0.6m
  • Weight – 1.8kg
  • IEC 61111 Matting

Contact T&D for prices, delivery and technical support for CATU Electrical MP-42/66.

LV-HV insulating matting also available for safe working on switchgears/switchboards up to 33kV  – see the complete range of MV medium voltage matting.

CATU MP-42/66 - MV Insulating Matting 26.5kV Class 3

CATU MP-42/66


Class 3 Insulating Mats

The following table includes the ranges of Class 3 insulating mats available from CATU Electrical for effective working to 26,500V – insulating thickness of 3mm.

Order Code  Electrical Matting Protection Voltage Insulation  Mats Thickness  Width  Length  Standard
CATU MP-42/11 Class 3 MV – 26,500V 3mm 1 metre 1 metre IEC61111
CATU MP-42/16 Class 3 MV – 26,500V 3mm 0.6 metre 1 metre IEC61111
CATU MP-42/66 Class 3 MV – 26,500V 3mm 0.6 metre 0.6 metre IEC61111
CATU MP-120/03-1 Class 3 MV – 26,500V 3mm 1.2 metre 1 metre IEC61111
CATU MP-60/03-5 Class 3 MV – 26,500V 3mm 0.6 metre 5 metre IEC61111
CATU MP-60/03-10 Class 3 MV – 26,500V 3mm 0.6 metre 10 metre IEC61111
CATU MP-100/03-5 Class 3 MV – 26,500V 3mm 1 metre 5 metre IEC61111
CATU MP-100/03-10 Class 3 MV – 26,500V 3mm 1 metre 10 metre IEC61111

CATU Electrical Safety MV HV

T&D stock and distribute the complete range of CATU Electrical Safety Equipment.

♦ See Also Class 3 Insulating Gloves | Voltage Detectors LV MV HV | Arc Flash Clothing | Substation Safety Kits

CATU Electrical Safety

Electrical Safety Equipment for Medium & High Voltage Systems

Data Sheets