E1XF Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 473AA)

E1XF Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian 473AA)

E1XF Cable Glands – Flameproof Ex e/Ex d & Explosion Proof

E1XF Cable Glands from the Prysmian 473AA range of hazardous area cable glands suitable for terminating circular steel wire armoured cables in Zone 1 and Zone 2 locations – Prysmian E1XF cable glands provide high performance in high temperatures and achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant.

E1XF Cable Glands – Prysmian 473AA

Flameproof Ex e/Ex d Cable Glands & Kits
  • E1XF brass indoor and outdoor hazardous area cable gland
  • Suitable for circular armoured cables with extruded cable with extruded polymeric bedding and oversheath
  • Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant
  • Weatherproof & waterproof cable gland
  • Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
  • Inner PCP seal grips cable bedding and provides additional ingress protection
  • Three part armour lock provides mechanical cable retention and electrical continuity
  • Service temperature range -60°C to +90°C
  • ATEX Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1
  • Nickel plated E1XF cable glands are available

➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.

Hazardous Area E1xF Cable Glands

PRYSMIAN 473AA

Hazardous Area Zone 1 Zone 2 Cable Glands

E1XF cable glands are suitable for use in:

  • Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
  • Zones 1 & 2 with Ex ib IIA, B & C Equipment
  • Zones 1 & 2 with Ex e II Equipment
  • Zone 2 with Ex nA II Equipment
  • Zones 21 & 22 with Ex tD II Equipment

Additionally, where the cable is effectively filled, the E1XF cable glands can be used in:

  • Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
  • Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
  • Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
  • Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
  • Zone 2 with Ex nR II Equipment

ATEX E1xF Cable Glands

ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.

 

Hazardous Cable Glands Prysmian

Cables & Accessories for Hazardous Areas

T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats

Prysmian Bicon Cable Gland Reference Cable Gland Size Cable Dimensions (mm) 473AA Cable Gland Dimensions (mm)
Under Armour Ø (A) Overall Ø (B) Armour Wire Ø Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon
Standard Nickel Plated Min Max Min Max A/F (G) A/C (H)
473AA-51 473AA-51V 16 3.8 8.7 8.0 13.2 0.2/0.3 M16×1.5 15 41 23.4 26.7
473AA-71 473AA-71V 20SS 3.8 8.7 8.0 13.2 0.2/0.3 M20×1.5 15 41 23.4 26.7
473AA-52 473AA-52V 20S 8.0 11.8 8.0 15.8 0.2/0.3 M20×1.5 15 43 25.7 29.2
473AA–53 473AA–53V 20 11.8 14.2 11.7 20.8 0.2/0.3 M20×1.5 15 43 30.5 34.0
473AA–55 473AA–55V 25 14.0 20.1 17.0 27.2 0.3/0.45 M25×1.5 15 48 37.6 42.2
473AA–56 473AA–56V 32 19.7 26.6 23.5 33.5 0.3/0.45 M32×1.5 15 53 47.2 53.6
473AA–57 473AA–57V 40 26.6 32.4 29.0 39.9 0.3/0.45 M40×1.5 15 56 56.4 61.5
473AA-58 473AA-58V 50S 32.4 38.4 38.0 46.2 0.3/0.45 M50×1.5 15 61 60.0 66.0
473AA–59 473AA–59V 50 38.4 44.3 39.5 52.6 0.3/0.45 M50×1.5 15 61 70.1 77.2
473AA–60 473AA–60V 63S 44.3 50.3 50.0 58.9 0.3/0.45 M63×1.5 15 64 75.0 83.0
473AA–61 473AA–61V 63 50.3 56.2 51.3 65.3 0.3/0.45 M63×1.5 15 64 80.0 87.4
473AA–62 473AA–62V 75S 56.2 62.2 62.0 71.6 0.3/0.45 M75x1.5 15 73 90.2 99.1
473AA–63 473AA–63V 75 62.2 68.1 62.5 78.0 0.3/0.45 M75x1.5 15 73 98.8 109.2
473AA–64 473AA–64V 85 68.0 74.0 68.0 88.0 0.3/0.45 M85x1.5 20 102 115.1 126.0
E1XF Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian 473AA)

E1XF Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 473AA)

Hazardous Area Offshore - Cables Joints Glands Cleats MV HV

Onshore & Offshore Cables For Hazardous Areas

Hazardous Area Cable Glands

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof