Associated Manufacturers

Contact us

Get quote

Excel Plus (NPT) Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 493NE)

Excel Plus (NPT) Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian 493NE)

Excel Plus Cable Glands – Flameproof Ex e/Ex d & Explosion Proof

Excel Plus Cable Glands from the Prysmian 493NE range of hazardous area cable glands suitable for terminating circular cables with braid, tape or wire armour and extruded polymeric bedding & oversheath in Zone 1 and Zone 2 locations – Prysmian Excel Plus cable glands achieve IP67 and deluge proof (DTS01:1991) seal onto cable and to enclosure with sealing washer supplied or thread sealant.

Excel Plus Cable Glands – Prysmian 493NE

Flameproof Ex e/Ex d Cable Glands & Kits
  • Excel Plus brass indoor and outdoor hazardous area cable gland
  • Suitable for circular armoured cables with extruded cable with extruded polymeric bedding and oversheath
  • Achieves IP67 and deluge proof (DTS01:1991) seal onto cable and to enclosure with sealing washer supplied or thread sealant
  • Weatherproof & waterproof cable gland
  • Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
  • Diaphragm inner seal compatible with soft bedding materials that may be subject to ‘cold flow’
  • Three part armour lock provides mechanical cable retention and electrical continuity
  • Service temperature range -20°C to +90°C
  • ATEX Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1
  • CSA certified Ex d IIC & Ex e II, CSA Enclosure Type 4X, AEx d IIC & AEx e II, NEMA 4X
  • Nickel plated Excel Plus cable glands are available

➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.

Hazardous Area Excel Plus Cable Glands

PRYSMIAN 493NE

Hazardous Area Zone 1 Zone 2 Cable Glands

Excel Plus cable glands are suitable for use in:

  • Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
  • Zones 1 & 2 with Ex ib IIA, B & C Equipment
  • Zones 1 & 2 with Ex e II Equipment
  • Zones 1 & 2 with Ex p II Equipment
  • Zone 2 with Ex nA II Equipment
  • Zones 21 & 22 with Ex tD II Equipment

Additionally, where the cable is effectively filled, the Excel Plus cable glands can be used in:

  • Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
  • Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
  • Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
  • Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
  • Zone 2 with Ex nR II Equipment

ATEX Excel Plus Cable Glands

ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.

 

Hazardous Cable Glands Prysmian

Cables & Accessories for Hazardous Areas

T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats

Prysmian Bicon Cable Gland Reference Cable Gland Size Cable Dimensions (mm) 493NE Cable Gland Dimensions (mm)
Under Armour Ø (A) Overall Ø (B) Max Armour Thickness Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon
Standard Nickel Plated Min Max Min Max A/F (G) A/C (H)
 493NE-03  493NE-03V ½ ”- 16 4 9 8 16 1.25 ½ ”NPT 15.5 73 25.7 28.7
 493NE-06  493NE-06V ¾” – 20SS 4 9 8 16 1.25 ¾”NPT 16.4 73 27.9 32.1
 493NE-04  493NE-04V ½” – 20S 7 12 9 16 1.25 ½ ”NPT 15.5 68 27.8 31.8
 493NE-07  493NE-07V ¾” – 20S 7 12 9 16 1.25 ¾”NPT 16.4 68 27.8 31.8
 493NE-08  493NE-08V ¾” – 20 8 14.4 11.5 21 1.25 ¾”NPT 16.4 76 33 36.9
 493NE-14 493NE-14V 1″ – 25 10.5 20.2 18.5 27.5 1.6 1″NPT 19.5 76 37.6 42.2
493NE-20 493NE-20V 1¼” – 32 15.5 26.5 21 34 2 1¼”NPT 20.5 86 47.2 53.6
493NE-27 493NE-27V 1½ ” – 40 23 32.5 31 41.5 2 1½”NPT 21 90 56.4 63.1
493NE-32 493NE-32V 2″ – 50 28.5 44.5 36 52.5 2.5 2″NPT 22 111 70 77.2
493NE-38 493NE-38V 2½ ” – 63 44 56.5 50 65.5 2.5 2½”NPT 32.5 112 80 87.4
493NE-45 493NE-45V 3″ – 75 53 68.5 59 78 2.5 3″NPT 33.5 130 98.8 109.2
Excel Plus (NPT) Cable Glands - Hazardous Area Exd IIC / Ex e II (Prysmian 493NE)

Excel Plus (NPT) Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 493NE)

Hazardous Area Offshore - Cables Joints Glands Cleats MV HV

Onshore & Offshore Cables For Hazardous Areas

Hazardous Area Cable Glands

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof