E1W-XL Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 474SW)

E1W-XL Cable Glands – Flameproof Ex e/Ex d & Explosion Proof
E1W-XL Cable Glands from the Prysmian 474SW range of hazardous area cable glands suitable for terminating circular aluminium wire armoured cables in Zone 1 and Zone 2 locations – Prysmian E1W-XL cable glands provide high performance in high temperatures and achieves IP67 seal onto cable and to enclosure with suitable sealing washer or thread sealant thanks to superior dual seals.
E1W-XL Cable Glands –Â Prysmian 474SW
Flameproof Ex e/Ex d Cable Glands & Kits
- E1W-XL brass indoor and outdoor hazardous area cable gland
- Suitable for circular armoured cables with extruded cable with extruded polymeric bedding and oversheath
- Achieves IP67 seal onto cable and to enclosure with suitable sealing washer or thread sealant
- Weatherproof & waterproof cable gland
- Cable glands certified to II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC
- Inner PCP seal grips cable bedding and provides additional ingress protection
- Continuity Connection for Lead Inner sheathed cables
- Three part armour lock provides mechanical cable retention and electrical continuity
- Service temperature range -60°C to +90°C
- ATEX Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1
- IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1
- Nickel plated E1W-XL cable glands are available
➡ MV-HV Cables. Medium voltage and high voltage cable glands for high fault current carrying capacity applications are available – visit medium voltage cables for 6.6kV, 11kV and 33kV cable specifications.
Hazardous Area E1W-XL Cable Glands
PRYSMIAN 474SW
E1W-XL cable glands are suitable for use in:
- Zones 0, 1 & 2 with Ex ia IIA, B & C Equipment
- Zones 1 & 2 with Ex ib IIA, B & C Equipment
- Zones 1 & 2 with Ex e II Equipment
- Zone 2 with Ex nA II Equipment
- Zone 21 & 22 with Ex tD A21
Additionally, where the cable is effectively filled, the E1W-XL cable glands can be used in:
- Zones 1 & 2 with Ex d IIC Equipment not containing a source of ignition and volume less than 2000cm³
- Zones 1 & 2 with Ex d IIA & Ex d IIB Equipment not containing a source of ignition/volume
- Zone 1 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and volume less than 2000cm³
- Zone 2 with Ex d IIA & Ex d IIB Equipment containing a source of ignition and with any volume
- Zone 2 with Ex nR II Equipment
ATEX E1W-XL Cable Glands
ATEX Certified Cable Gland II 2GD, Ex e II & Ex d IIC.
Cables & Accessories for Hazardous Areas
T&D also distribute Prysmian Draka Offshore Cables for LV-HV power, control and instrumentation – flameproof hazardous area cable joints, cable cleats and cable transit sealing systems for low, medium and high voltage cables. See also: Prysmian Cable Cleats
Prysmian Bicon Cable Gland Reference | Cable Gland Size | Cable Dimensions (mm) | 474SW Cable Gland Dimensions (mm) | ||||||||||||||||||||||
Under Armour Ø (A) | Overall Ø (B) | Armour Wire Ø | Braid Armour Wire Ø | Lead Sheath Ø | Entry Thread (D) | Thread Length (E) | Protrusion Length (F) | Hexagon | |||||||||||||||||
Standard | Nickel Plated | Min | Max | Min | Max | Min | Max | A/F (G) | A/C (H) | ||||||||||||||||
474SW-71 | 474SW-71V | 20SS | 3.8 | 8.7 | 8.0 | 13.2 | 0.9 | 0.2/0.3 | 3.0 | 8.0 | M20×1.5 | 15 | 41 | 23.4 | 26.7 | ||||||||||
474SW-52 | 474SW-52V | 20S | 8.0 | 11.8 | 8.0 | 15.8 | 0.9/1.25 | 0.2/0.3 | 4.0 | 12.0 | M20×1.5 | 15 | 43 | 25.7 | 29.2 | ||||||||||
474SW-53 | 474SW-53V | 20 | 11.8 | 14.2 | 11.7 | 20.8 | 0.9/1.25 | 0.2/0.3 | 7.0 | 14.0 | M20×1.5 | 15 | 43 | 30.5 | 34.0 | ||||||||||
474SW-55 | 474SW-55V | 25 | 14.0 | 20.1 | 17.0 | 27.2 | 1.25/1.6 | 0.2/0.45 | 10.0 | 20.0 | M25×1.5 | 15 | 48 | 37.6 | 42.2 | ||||||||||
474SW-56 | 474SW-56V | 32 | 19.7 | 26.6 | 23.5 | 33.5 | 1.6/2.0 | 0.3/0.45 | 15.0 | 26.0 | M32×1.5 | 15 | 53 | 47.2 | 53.6 | ||||||||||
474SW-57 | 474SW-57V | 40 | 26.6 | 32.4 | 29.0 | 39.9 | 1.6/2.0 | 0.3/0.45 | 20.0 | 32.0 | M40×1.5 | 15 | 56 | 56.4 | 61.5 | ||||||||||
474SW-58 | 474SW-58V | 50S | 32.4 | 38.4 | 38.0 | 46.2 | 2.0/2.5 | 0.3/0.45 | 24.0 | 38.0 | M50×1.5 | 15 | 61 | 60.0 | 66.0 | ||||||||||
474SW-59 | 474SW-59V | 50 | 38.4 | 44.3 | 39.5 | 52.6 | 2.0/2.5 | 0.3/0.45 | 29.0 | 44.0 | M50×1.5 | 15 | 61 | 70.1 | 77.2 | ||||||||||
474SW-60 | 474SW-60V | 63S | 44.3 | 50.3 | 50.0 | 58.9 | 2.5 | 0.3/0.45 | 34.0 | 50.0 | M63×1.5 | 15 | 64 | 75.0 | 83.0 | ||||||||||
474SW-61 | 474SW-61V | 63 | 50.3 | 56.2 | 51.3 | 65.3 | 2.5 | 0.3/0.45 | 42.0 | 56.0 | M63×1.5 | 15 | 64 | 80.0 | 87.4 | ||||||||||
474SW-62 | 474SW-62V | 75S | 56.2 | 62.2 | 62.0 | 71.6 | 2.5 | 0.3/0.45 | 49.0 | 62.0 | M75×1.5 | 15 | 73 | 90.2 | 99.1 | ||||||||||
474SW-63 | 474SW-63V | 75 | 62.2 | 68.1 | 62.5 | 78.0 | 2.5 | 0.3/0.45 | 55.0 | 68.0 | M75x1.5 | 15 | 73 | 98.8 | 109.2 | ||||||||||
474SW-64 | 474SW-64V | 85 | 68.0 | 74.0 | 68.0 | 88.0 | 3.2 | 0.3/0.45 | 63.0 | 72.0 | M85x2 | 20 | 102 | 115.1 | 126.0 |

E1W-XL Cable Glands – Hazardous Area Exd IIC / Ex e II (Prysmian 474SW)

Onshore & Offshore Cables For Hazardous Areas

Cable Glands – Flameproof Ex e/Ex d & Explosion Proof