ABB designs the PEXLIM range to protect electrical infrastructure against overvoltages caused by lightning strikes and switching operations.
Thorne & Derrick supplies ABB surge arresters for high voltage applications, helping UK Distribution Network Operators (DNOs), contractors and substation operators protect critical electrical assets.
ABB PEXLIM 132kV Surge Arresters
The ABB PEXLIM surge arrester protects 132kV electricity networks and high voltage equipment against damaging overvoltages.
Electrical engineers install surge arresters across a range of applications, including:
High voltage substations
Power transformers
Switchgear and capacitor banks
Electric motors and bushings
High voltage cables
Overhead line-to-underground cable transitions
In particular, surge arresters help protect critical equipment at points where overhead power lines connect to underground cable networks.
ABB engineers the PEXLIM range to provide reliable overvoltage protection for demanding high voltage applications.
UK DNO’s take the uninterrupted supply of electricity to our homes and business seriously, very seriously.
Surge Arresters
T&D working with ABB can provide surge arresters for electrical protection of all types of medium/high voltage MV HV assets – view the Buyers Guide or better still call us to discuss your particular requirements. Surge arresters can be supplied with compliance to all UK DNO specification requirements including WPD, Northern Powergrid, UKPN and Scottish & Southern Energy (SSE).
ABB surge arresters protect HV electrical power supply systems against the catastrophic effects of lightning and switching overvoltages.
Since 1985 Thorne & Derrick based in the UK have been specialist distributors of LV, MV & HV Cable Installation, Jointing, Substation, Arc Flash Clothing & Electrical Equipment – customers include UK and worldwide contractors, specifiers, traders and end-users involved in cable installations, sealing cable ducts, cable jointing, substation earthing, overhead line and electrical construction at Low, Medium & High Voltages up to 132kV.
Should you require any technical support, specification guidance or would like us to visit you and discuss the range of ABB Surge Arrester products please do not hesitate to contact us – T&D are proud to distribute the ABB ranges of MV HV Electrical Equipment.
Chris Dodds (T&D) with Donald Thompson (ABB MV Surge Arrester Sales Manager) at Thorne & Derrick’s office in County Durham UK earlier today.
T&D Main UK Suppliers Of Lucy Zodion Feeder Pillars
Feeder Pillars
Case Study 1
Working with the M&E Contractor and their Consultant Engineers, T&D have supplied road lighting feeder pillars to provide reliable low voltage power distribution to an urban design and infrastructure project predicted to deliver £74.2m in gross value added to the local economy in South Yorkshire.
The road lighting feeder pillars were supplied by T&D with anti-vandal lock, detachable root section and painted to RAL9005 Abcite Black colour scheme.
Abcite thermoplastic powder coatings provide tough, impact resistant protection for outdoor pillars without a primer undercoat – excellent corrosion and UV protection.
Project Details:Advanced Manufacturing and Research Centre Campus (AMRC2), Sheffield UK – 860,000 sq ft of advanced manufacturing and research space, 468,000 sq ft for a residential training centre and conferencing and 16,000 sq ft for outdoor and indoor recreation. The original University-backed AMRC on the Advanced Manufacturing Park (AMP) now comprises more than 40 companies including Rolls-Royce and Boeing – a nucleus of innovation, research and technology designed for collaboration and rapid commercialisation.
T&D distribute the complete range of Lucy Zodion feeder pillars for low voltage power distribution to the building services, rail, construction, utilities, oil and gas, retail and leisure, ports, airports and heavy industries – GRP, cast iron, galvanised and stainless steel types customised to your application:
Pre-Wired Power Distribution Panels (Outdoor IP65 & Underground Retractable)
Substation Power, Cable Distribution & LV Interconnection Panels (Onshore Wind)
DNO Single & 3 Phase Network Pillars (25A-800A)
Network Rail & Electrification – Station & Trackside Pillars (incl. London Underground)
Low Voltage Connections – New Housing & Commercial Development Pillars (LV)
Defence Estates MoD – Load Shedding Fuse Pillars
Lighting Feeder Pillars – Street, Road, Flood, Sports Stadium & Car Parks
BT Telecommunications & Interface Pillars
Environment Agency – Rivers, Coastal & Waterways
Cast Iron Electrical Distribution Pillars – National Heritage & Historic Buildings
âž¡ For further information about how Lucy Zodion provide control and power distribution products for street lighting applications, please review the Lucy Titan (Cut-outs) and Lucy Trojan (Isolators) ranges of products.
âž¡ Contact us to discuss how T&D and Lucy Zodion can provide innovative custom design solutions and ex stock delivery of standard feeder pillars to your project.
Overhead Line Equipment – Suppliers Of Medium & High Voltage Electrical Equipment
Thorne & Derrick International, are Specialist Distributors of an extensive range of Overhead Line Equipment used to erect, construct and maintain LV-HV power lines.
We service UK DNO’s, global utilities and their contractors involved in the installation and maintenance of Overhead Transmission and Distribution power lines with electrification equipment including 33kV joints, terminations and connectors and arc flash clothing to protect linesmen and jointers against the risks and hazards associated with arc incident.
Need Products Quick?
T&D can source all your Overhead Line Equipment – we provide excellent customer service and competitive prices with UK or overseas delivery.
Hydraulic heads and battery tools for power line cutting and compression of crimping connectors, terminals and joints used in high voltage electrical transmission and distribution.
CreditABB – Joint, Terminate & Connect Medium & High Voltage Cables
Thorne & Derrick
T&D are UK distributors and worldwide exporters of LV, MV & HV Cable Installation, Cable Jointing, Duct Seals, Substation & Electrical Equipment – we service UK and global businesses involved in cable installations, jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV.
Since 1985, T&D have established a solid reputation based on Service, Integrity and Trust – contact us with your enquiry.
by Chris Dodds T&D - estimated reading time 5 minutes
The following LinkedIn Comments provide expert guidance and advice on how to remove fabric layers from MV-HV cables without jeopardising or compromising cable functionality.
Medium & High Voltage Cable Jointing
Cable type pictured is 15kV Medium/High Voltage power cable
15kV MV Primary UD EPR Cable Specification
Primary Underground Distribution Cable (Single Phase)
Aluminium Conductor 750 MCM
EPR (Ethylene Propylene Rubber) Insulation
Easy Strippable Insulation Shield
Application – Medium voltage primary underground distribution cable for conduit systems, direct burial, underground cable duct
Manufacturer – CME Mexico (CME Wire and Cable, Inc. was established in the USA in 1994 as a subsidiary of Viakable to serve customers in the US and Canada).
How To Remove Fabric Layers From MV HV Power Cables
David Lundin (Contractor Compliance Specialist at Western Power)Â – remove the cable fabric layer by gloved hand and clean away residual material with carbon tetra chloride or equivalent cable cleaners.
Erik Liljedahl (Site Intallation Manager on NKT HV High Voltage Cables) – carefully remove the band with a knife, be careful not to damage the cable conductor strands, then brush the conductor with a wire brush. This fabric is to prevent the inner semi-conductor to fall between the conductor strands during cable production and allows the XLPE insulation to move during heat treatment – this fabric is usually a present layer on 100kV-600kV cables but also 11kV-33kV.
Peter Hembry (Director at Hembry High Voltage Services) – unravel to the primary insulation and pull it against the blade of a sharp knife all the way around, then give it a quick lick of heat to catch any strands you may have missed.
Ben Lanz (Director, Applications Engineering at IMCORP) – unless this is an unusual cable design, the inner semi-conductor (conductor shield) layer should come off cleanly. Any residue can be typically wiped off with a lint free cloth. After you wire brush the aluminium oxide off the conductor and immediately apply the oxide inhibitor, you will be ready to apply the connector (either compression or mechanical shearbolt). If you are not familiar with MV and HV cable in general, I recommend jointer/splicer training.
Mark Jones (Renewables Marketing Manager at Synergy Cables USA Ltd)– box cutter with a new blade works well. Cut slowly while keeping tension by rolling it under itself.
David Tompsett (Project Engineer at Northern Ireland Electricity)Â – seen this conductor screen removed by using twine instead of a knife. Good clean edge and no risk of damage to the outer conductor strands of the MV-HV cable.
Glyn Moore TMIETÂ (Electrical Tech / Construction Manager)Â – as previous comments to remove the fabric either under or over wrapped once you are square with your insulation pull the fabric onto a sharp blade away from conductor, bit of a flame from a heat shrink torch to remove loose fibres.Â
Darren Street (Cable Jointer at D+R Jointing Services Ltd) – sharp knife and a trained cable jointers touch (also blow it over with a gas torch to catch any wayward strands).
Ciaran McDowell (HV / LV Authorised Cable Jointer)Â – used it on high voltage tails in medium/high voltage transformers a few years ago. Use a sharp knife like a Stanley and pull the fabric under tension against the blade. This worked well just leaving a few threads to trim off.Â
Eoin MacQuaile (Junior Quantity Surveyor at Obelisk) – use a piece of twine and wrap it around the cable material and use a saw-like motion to heat and cut the fabric without scoring the aluminium. This method evenly cuts insulation and wrapping without damaging conductors.
Kevin Kruse (Vice President, Engineering and Technical Support)Â – I have completed many cable termination demonstrations and we were always made fun of because we used string, but this is safest method. Second is some of the tools like Speed Systems or Ripley Jointing Tools where you can set a safe depth just shy of the conductor diameter. Cable jointers should never use a knife or box cutter.
Tim Poirier (HV Systems Manager- North America TE Connectivity)Â – best method is to tear it and then using a cable splicing knife at the cut back tearing it against the blade being careful not to nick the aluminium if any strands of the fabric remain burn off with a heat shrink torch.
Justin Kelly (Underground Network and Cable Splicer at JEA) – knife work, the cornerstone of legitimate medium voltage cable splicing and jointing. This is why splicing has historically been taught in 4-5 year apprenticeships, not 6 week classes. Skill takes time.
Stephen Davies (Technical Policy Engineer – Western Power Distribution) – this should be pulled against a static knife edge by the cable jointer so as to not damage the aluminium conductor. It is a semiconductor woven tape that prevents the semicon extruded layer bedding between the aluminium strands.
âž¡ String is simple but effective for clean cutting without damaging underlying cable conductors.
MV HV Power Cables
Primary Underground Distribution MV Medium Voltage Cables
Primary UD MV Cable TR-XLPE / LLDPE, Concentric Neutral
Primary UD MV Cable EPR / LLDPE, Concentric Neutral
Primary UD MV Cable TR-XLPE / PVC, Concentric Neutral
Primary UD MV Cable EPR / PVC, Concentric Neutral
Primary UD MV Cable PILC Replacement, EPR/PE
Primary UD MV Cable TR-XLPE Insulated, Concentric Neutral
Primary UD MV Cable EPR Insulated, Concentric Neutral
High & Extra High Voltage Cables & Cable Systems
High Voltage Copper Cable, Smooth Aluminum Shield/Sheath, XLPE Insulation, HDPE Jacket, 69kV – 138kV
High Voltage Copper Cable, Wire and Tape Shield, XLPE Insulation, HDPE Jacket, 69kV – 138kV
High Voltage Aluminum Cable, Smooth Aluminum Shield/Sheath, XLPE Insulation, HDPE Jacket, 69kV – 138kV
High Voltage Aluminum Cable, Wire and Tape Shield, XLPE Insulation, HDPE Jacket, 69kV – 138kV
Extra High Voltage Copper Cable, Smooth Aluminum Shield/Sheath, XLPE Insulation, HDPE Jacket, 230kV
Extra High Voltage Aluminum Cable, Smooth Aluminum Shield/Sheath, XLPE Insulation, HDPE Jacket, 230kV
T&D are UK Main Stockist for Alroc Tools suitable for all types of LV MV HV cable preparation prior to installing cable joints, terminations and separable connectors.
International standards and local practices vary considerably, here a Indian cable jointing team are shown using knives and hacksaws to remove cable sheath jacket and primary insulation from Prysmian 220kV to 550kV EHV cables. Image: Audhesh Giri (EHV Cable Jointer/Cable Supervisor)
Here a smooth finish to the XLPE insulation on a high voltage power cable has been achieved with use of a Makita sanding machine
THORNE & DERRICK are national distributors of LV, MV & HV Cable Installation, Jointing, Duct Sealing, Substation & Electrical Equipment – we service UK and global businesses involved in cable installations, cable jointing, copper earth tapes and substation earthing at LV, 11kV, 33kV and EHV.
Based in the UK, are the Specialist Distributor for the Nexans Power Cable Accessoryrange of Screened Separable Connectors (Euromold), Cold-Applied (AIN AFN)& Heat Shrink Joints (JTS)& Cable Terminations (MONO) for Medium Voltage Power Systems up to 66kV; we hold extensive stocks and provide the most competitive commercial and technical levels of customer service in the UK.
Thorne & Derrck are committed to honour the Armed Forces Covenant and support the Armed Forces Community – a signed copy is available below as a download.
We recognise the value Serving Personnel, both Regular and Reservists, Veterans and military families contribute to our business and our country.
The Armed Forces Covenant is a promise from the nation that those who serve or have served, and their families, are treated fairly.
Armed Forces Covenant – Thorne & Derrick International
What Is Arc Flash PPE and Why Is It Important? Arc flash PPE is specialist personal protective equipment designed to help protect electrical workers against the thermal hazards of an electric arc. It includes arc-rated clothing, protective helmets, face...
Voltage detectors are electrical safety instruments used to identify the presence or absence of voltage on electrical equipment and conductors. They are used by electricians, electrical engineers, utilities and maintenance teams working on low voltage (LV), medium voltage (MV)...