ABB Cable Joints & Cable Terminations 11kV 33kV (12kV-42kV)

ABB Cable Joints & Cable Terminations 11kV 33kV (12kV-42kV)

Cable Joints & Cable Terminations


Thorne & Derrick | Distributed from Stock | Approved Supplier | UK & Export Sales


Cable Joints & Cable Terminations

11kV 33kV (12kV-42kV)

ABB offers a complete range of connectors, joints, terminations from 12kV-42kV for the medium and high voltage (MV HV) cable networks. The ABB range consists of prefabricated or pre-moulded solutions for indoor and outdoor applications.

The Cable Joints & Terminations plus accessories are designed for installations in switchgears, transformers, overhead lines, wind power stations and other installations.

HV Cable Joints - Heat Shrink Joints 6.6kV 11kV 33kV High Voltage Cables


ABB Product Description Benefits & Features Suggested Applications
Cable terminations indoor and outdoor
ABB SOT 7.2-36kVCable terminations indoor and outdoor - SOT 7.2-36 kV
SOT is a pre-moulded cable termination with silicone
rubber sleeve with integrated field control
and top sealing. The outdoor variant has permanent
sheds, which give an extended creepage
distance. Indoor kit can also be installed in
a humid environment. The design contains few
components. The terminations are supplied in kits
for 1 or 3-core cables. Kits for outdoor termination
for 3-core cable includes a crutch seal.
Designed for installations in switchgears,
transformers, wind power stations and
other similar installations.
Indoor termination with geometrical field control
ABB APIT 12-36kVIndoor termination with geometrical field control - APIT 12-36 kV
APIT is a prefabricated indoor cable termination
for XLPE and EPR-insulated 1 or 3-core cables
with especially high demands on function, such
as environments with voltage harmonics.
The cable termination is made of rubber with
prefabricated geometrical field control.
Designed for installations in switchgears,
transformers, wind power stations and
other applications where high frequency
harmonics may occur.
Outdoor termination with geometrical field control
ABB APSEA 12-36kVOutdoor termination with geometrical field control - APSEA 12-36 kV
APSEA is a pre-moulded outdoor cable termination
for XLPE and EPR insulated 1 or 3-core cables
with especially high demands on function, such
as environments with voltage harmonics.
The cable termination is made of rubber with
prefabricated geometrical field control.
Designed for installations in switchgears,
transformers, wind power stations and
other applications where high frequency
harmonics may occur.
Outdoor cable terminations
ABB APED 12-36kVOutdoor cable terminations APED 12-36 kV
APED cable termination consists of a composite
insulator fitted on a box body made of aluminium.
The electrical stress control component is a
pre-moulded rubber stress cone. The insulator has
sheds of short-long type and is filled with synthetic insulating oil.
A post insulator kit which includes three stand-off
insulators and a supporting plate used for insulated
installation can be included.
Designed for installations on overhead
lines, transformers or air-insulated
switchyards. It is also suitable for outdoor
and indoor installations in which the
termination is to be used as a fixed
connection point and for installations
where there is a risk of continuous very
high creepage currents.
Screened separable cable connector
ABB CSS-A and CSE-A 250 A for 12-24kVScreened separable cable connector CSS-A and CSE-A 250 A for 12-24 kV
These are pre-moulded screened separable connectors for XLPE-insulated 1 or 3-core 12-24 kV cables, with aluminium or copper conductors, copper wire screens or copper tape screens, and with or without aluminium or steel wire armouring. They can be installed indoors and outdoors and are supplied with screw cable lug and screw connection. The cable connectors include a capacitive test point with protection and an integrated earthing wire. Designed for installations in switchgears, transformers, wind power stations and other similar installations.
Screened separable cable connector
ABB CSE-A 400 A for 12-42kVScreened separable cable connectorCSE-A 400 A for 12-42 kV
These are pre-moulded screened separable connectors for XLPE-insulated 1 or 3-core 12-24 kV cables, with aluminium or copper conductors, copper wire screens or copper tape screens, and with or without aluminium or steel wire armouring. They can be installed indoors and outdoors and are supplied with screw cable lug and screw connection. The cable connectors include a capacitive test point with protection and an integrated earthing wire. Designed for installations in switchgears, transformers, wind power stations and other similar installations.
Screened separable cable connector
ABB CSE-A 630 A for 12-42kVScreened separable cable connector CSE-A 630 A
These are pre-moulded screened separable connectors for XLPE-insulated 1 or 3-core 12-24 kV cables, with aluminium or copper conductors, copper wire screens or copper tape screens, and with or without aluminium or steel wire armouring. They can be installed indoors and outdoors and are supplied with screw cable lug and screw connection. The cable connectors include a capacitive test point with protection and an integrated earthing wire. Designed for installations in switchgears, transformers, wind power stations and other similar installations.
Screened separable parallel connector
ABB CSEP-A 630 A for 12-42kVScreened separable parallel connector CSEP-A 630 A
CSEP-A is a screened separable parallel connector designed to be connected to a screened separable connectors type CSE-A 630 A, fits systems for 12-42 kV. It fulfils the requirements of CENELEC HD 629.1 S2. Complete kits available for cables with copper wire or copper tape screen. CSEP-A is a complement to CSE-A, to be used whenever there is a need to install more than one cable in parallel to a bushing. Designed to fit an already installed CSE-A connector, with the advantage to fit compartments with limited space.
Surge arrester
ABB CSAP-A 630 A for 12-24kVSurge arrester CSAP-A 630 A
The pre-moulded surge arrester is designed to be connected in parallel with screened separable connectors type CSE-A 630 A. Fits systems for 12-24 kV. CSAP-A fulfils the requirements of IEC 60099-4. It protects electrical components against overvoltage and transients and provides a compact installation. Designed for installations in switchgears, transformers, in wind power stations and other installations, connected in parallel with ABB screened separable connectors type CSE-A 630 A.
Pre-moulded cable joint
ABB SOJ 12-24kVPremolded cable joint SOJ 12-24 kV
The body of the joint is made from three layers of rubber − a conductive outer layer, an insulating layer and a conductive inner layer. The joint body is pre-expanded on plastic inserts before installation. When the cables have been connected and the joint is centred, the inserts are pulled out. This way the joint body provides active pressure on the cable insulation. For jointing 12-36 kV XLPE and EPR-insulated 1 or 3-core cables with aluminium or copper conductors.
Cable cabinet
ABB HDC-A 12-24 kV for 250ACable cabinet HDC-A12-24kV for 250A
The enclosure is made of hot-dip galvanized steel plates with a foundation base plate, and additional corrosion protection on components that are installed underground. There is no need for plain concrete foundation or anything similar.
The screened separable cable connectors are connected with coupling pieces pre-mounted in the cabinet.
The enclosure fulfils the requirements for mechanical impact testing according to IEC 60439-5.
The cable connectors fulfil the electrical requirements according to CENELEC, HD 629.1 S2.
For jointing or branching XLPE-insulated 1-core or 3-core, 12-24 kV cables with conductor cross sections 10-95 mm²,
250 A. When branching in a cable grid, a branching point may be necessary to enable selected cable runs to be sectionalized during maintenance. With HDC-A. A solution for this is provided in HDC-A and up to 3 cables can be connected in parallel.
Cable cabinet
ABB HDC-A 12-36 kV for 630ACable Cabinet HDC-A 12-36 kV for 630 A
The enclosure is made of hot-dip galvanized steel plates with a foundation base plate, and additional corrosion protection on components that are installed underground. There is no need for plain concrete foundation or anything similar. The screened separable cable connectors are connected with coupling pieces pre-mounted in the cabinet.
The enclosures fulfils the requirements for mechanical impact testing according to IEC 60439-5.
The cable connectors fulfil the electrical requirements according to CENELEC, HD 629.1 S2.
For jointing or branching XLPE-insulated 1-core or 3-core, 12-36 kV cables with conductor cross sections 25-630 mm², 630 A. When branching in a cable grid, a branching point may be necessary to enable selected cable runs to be sectionalized during maintenance. With HDC-A, a solution is provided that makes this possible. Up to 4 cables can be connected in parallel.
Cold shrink cable terminations indoor and outdoor
ABB CST 12-42kVCold shrink cable terminations indoor
The body of these cold shrink terminations are
made of high elastic liquid silicone rubber with
hydrophobic and erosion resistant performance.
The termination can be installed by pulling out the spiral and the termination body shrinks tightly on cable insulation. Supplied in kits for 1 or 3-core cables with cold shrink protective hose, crutch seal and cable earthing braids included in the kits.
Designed for installations in switchgears,
transformers, wind power stations and other similar installations. For connecting 12-42 kV XLPE-insulated 1 or 3-core cables with aluminium or copper conductors.
Cold shrink cable joint
ABB JS-A 12-42kVCold shrink cable joint JS-A 12-42 kV
The body of the cold shrink joint is made from three layers of rubber – a conductive outer layer, an insulating layer and a conductive inner layer. The joint body is pre-expanded on spiral core in factory. When the cables have been connected and the joint is centred, the spiral are pulled out. This way the joint body will provides active pressure on the cable insulation. For jointing 12-42 kV XLPE and EPR-insulated, 1 or 3-core cables with aluminium or copper conductors.
Screened separable cable connector
ABB CSE-B 630 A for 12-24kVScreened separable cable connector CSE-B 630 A for 12-24 kV
Pre-moulded screened separable connectors for XLPE-insulated 1- or 3-core 12-24 kV cables, with aluminium or copper conductors, copper wire screens or copper tape screens, and with or without aluminium or steel wire armouring. Can be installed both indoors and outdoors. It is supplied complete with crimp cable lug and screw connection. The cable connectors include both a capacitive test point with protection and an integrated earthing wire. Designed for installations in switchgears, transformers, wind power stations and other similar installations.
Screened separable cable connector
ABB CSEP-B 630 A for 12-24kVScreened separable cable connector CSEP-B 630 A for 12-24kV
CSEP-B is a screened separable parallel connector designed to be connected to a screened separable connectors type CSEP-B 630 A, fits systems for 12-24 kV. CSEP-B is a complement to CSE-B, to be used whenever there is a need to install more than one cable in parallel to a bushing. Designed to fit an already installed CSE-B connector, with the advantage to fit compartments with limited space. Complete kits available for cables with copper wire or copper tape screen.
Surge arrester
ABB CSA-B and CSAP-B 630 A for 12kVSurge arrester CSA-B and CSAP-B 630 A for 12 kV
The pre-moulded surge arrester is designed to be connected in parallel with screened separable connector type CSE-B 630 A. CSA-B is front surge arrester and CSAP-B is rear surge arrester. Fits systems for 12kV. Protects electrical components against overvoltage and transients. Provides a compact installation. Designed for installations in switchgears, transformers, wind power stations and other similar installations, connected in parallel with ABB screened separable connectors type CSE-A 630 A.
GIS plug-in termination
ABB TP-A, 42kVGIS plug-in termination TP-A, 42 kV
The TP-A fits the standard bushing of 2# and 3# inner cone GIS switch cabinet or transformer according to EN 50181. Field control unit is integrated stress cone which is made of silicone rubber. The connector is fixed with cable conductor by bold so that no special tools are required during installation. GIS plug-in cable termination for XLPE insulated 1-core or 3-core cable with copper conductors up to 42 kV.

*Please note: This is ABB’s global offering and some products might not be available in your country. For more information and local contacts, please contact T&D for information.

Cable Joints Cable Terminations 3M ABB

Cable Joints Cable Terminations 3M ABB


ABB

ABB pioneered high voltage gas-insulated switchgear (GIS) more than 50 years ago and is a global leader offering a full-range product portfolio with voltage levels from 72.5kV to 1200kV matching current and future requirements for modern switchgears and power grids.

As a market leader in high voltage GIS technology, ABB has a global installed base of more than 35,000 bays. In a power system, switchgear controls, protects and isolates electrical equipment to boost the reliability of power supply.

GIS is a compact metal encapsulated switchgear consisting of high voltage components such as circuit-breakers and disconnectors.

Thorne & Derrick