Underground Cable Pulling Lubrication | Cable Lubricant | MULEGLIDE
Underground Cable Pulling Lubrication MULEGLIDE MV HV
NEPTCO, the makers of MULETAPE, have introduced a long-lasting silicone cable pulling lubricant called MULEGLIDE, an ideal medium-viscosity or high-viscosity Underground Cable Pulling Lubrication, allowing for swift and safe underground cable installation. Also available as cable blowing applications, LV Underground Cable Blowing Lubrication MULEGLIDE.
The CBLM MV HVÂ cable lubricant is designed with a non-drying formula, delivering smooth, consistent results with effortless application, making cable removal as easy as cable installation. MULEGLIDE Underground Cable Pulling Lubrication is engineered for efficiency and ease, offering reduced cable pulling tension, reducing risk of injury and cable damage, as well as faster pulls and lower friction.

Underground Cable Pulling Lubrication MULEGLIDE CBLM MV HV in Use
âž¡ View Thorne & Derrick’s complete range of Cable Lubricants for LV, MV and HV cable installations into duct – compatible with LV, 11kV, 33kV, 66kV and 132kV power cables with following type cable sheath/jackets:
MULEGLIDE CBLM MV HV Benefits
- Lubricity that lasts, longevity and optimised formula
- Specially designed formulation for enhanced field performance
- Ease of handling and quick clean up
- Silicone-based formulation specially formulated for all underground cable placement
- Deposits a non-drying silicone formulation enabling long-lasting coating on cable exterior surface resistant to friction and tension build-up
- Enables rapid installation without drying or tension by depositing super low friction components
- Fast pouring spout for easy-to-apply cable lubricant and ease of installation
- Smooth feel resists gel or string build-up in application and provides enhances operator experience in the field
- Reduced pulling tension resulting in improved worker safety and reduced operating hazards
Cable Lubricant MULEGLIDE Technical Specifications
The following tables provides further insight on the Underground Cable Pulling Lubrication MULEGLIDE CBLA MV HV, including product properties and varied test methods:
MULEGLIDE CBLM MV Technical Specifications | ||
Properties | Test Method | Value |
Appearance | Pourable, White Translucent Liquid | |
Brookfield Viscosity (2 rpm) | ASTM D2196 | 2000 – 5000 cps (25°C) |
Density | ASTM D1475 | 8.3 lbs/gallon |
Non-volatile Solids | 2-3% | |
pH | 6-8 | |
Temperature Use Range | 20°F to 130°F (-7°C to 54°C) | |
Temperature Stability | Freeze/Thaw | Pass |
Flammability | UL94 | Product as applied is non-flammable, Residue meets V0 rating |
Evaporation | Leaves behind lubricating film | |
Lubricant Slip Characteristic | TBD | |
Toxicity | Nontoxic-No issues per SDS | |
Clean Up | Wipes away with rag |
MULEGLIDE CBLM HV Technical Specifications | ||
Properties | Test Method | Value |
Appearance | Pourable, White Translucent Liquid | |
Brookfield Viscosity (2 rpm) | ASTM D2196 | 30,000 – 50,000 cps (25°C) |
Density | ASTM D1475 | 8.3 lbs/gallon |
Non-volatile Solids | 2-3% | |
pH | 6-8 | |
Temperature Use Range | 20°F to 130°F (-7°C to 54°C) | |
Temperature Stability | Freeze/Thaw | Pass |
Flammability | UL94 | Product as applied is non-flammable, Residue meets V0 rating |
Evaporation | Leaves behind lubricating film | |
Lubricant Slip Characteristic | COF < 0.1 straight pull* | |
Toxicity | Nontoxic-No issues per SDS | |
Clean Up | Wipes away with rag |
In this short video, Chase Corporation (NEPTCO) provide an insightful overview on the MULEGLIDE cable lubricant products, highlighting the products in use, how it compares with related competitor products and the extensive benefits of using MULEGLIDE.
Instructions | MV HV CBLM MULEGLIDE

MV Underground Cable Pulling Lubrication MULEGLIDE | Force vs Velocity Data Graph
How to Use MULEGLIDE Medium-Viscosity & High-Viscosity Cable Lubricant
Quantities will vary depending on cable and duct diameter, condition of duct, and terrain the duct is placed in.
- Remove the pour spout plug
- Carefully create a vent hole in the pail lid
- Apply lubricant according to the formula below
Underground Cable Pulling Lubrication Application & Compatibility
Suggested application: Q x L x D
Quantity = .0008 (gallons)

HV Underground Cable Pulling Lubrication MULEGLIDE | Force vs Velocity Data Graph
L = Length of pull (feet)
D = Diameter of the conduit
Compatibility:
MULEGLIDE is compatible with most cable jacket types. Please check with Thorne & Derrick directly for details.
MULEGLIDE CBLM MV HV Product Variants | ||
Package | 1 Gallon Pail | 5 Gallon Pail |
MULEGLIDE CBLM MV | 75224 (4/case) | 75216 (1/case) |
MULEGLIDE CBLM HV | 75224 (4/case) | 75213 (1/case) |
High Voltage Cable Systems & Accessories
Thorne & Derrick distribute the most extensive range of MV HV Medium & High Voltage Cable Joints, Terminations & Connectors from manufacturers including 3M, Prysmian, Nexans Euromold, Elastimold, Pfisterer CONNEX & SEANEX and Shrink Polymer Systems.
Heat shrink, cold shrink, push-on and slip-over cable accessories enable the jointing, terminating and connection of 11kV-33kV and 66kV-132kV cables to oil, air or gas insulated switchgear, transformers, motors and overhead lines distributing electricity at medium/high voltages.
NEPTCO | Cable Pulling & Detection
Global Leaders in Engineering & Manufacturing Cable Pulling & Detection Products
Part of the Chase Corporation Group, NEPTCO engineers and manufacturers a wide range of materials for commercial, industrial and military applications, including materials used for the pulling and detection of cables, as well as their well-known MULETAPE pulling tapes products. Thorne & Derrick provide competitive prices, exceptional customer support and product knowledge, all with next-day delivery for NEPTCO products.