Lucy Zodion Titan2 Street Lighting Cut Outs – Single & Double Pole
Published 16 Apr 2019
-
Uploaded By - Chris Dodds (Thorne & Derrick Sales & Marketing Manager)
Street Lighting Cut Outs
Lucy Zodion Ltd, are the leading UK manufacturer of street lighting cut-outs, controls, feeder pillars and street lighting isolators – their street light cut outs (SLCOs) are also part of the G81 specification framework.
Lucy Zodion Titan2 cut outs are supplied as standard with features that ensure the street lighting technicians task is considerably easier.
The Lucy Titan2 cam lever handle enables effortless release of the Lucy fuse carrier in one movement and there is plenty of cabling space to terminate a wide variety of conductor types and sizes.
Insulated or brass cable gland plates are also available for when dual or triple entries are required.
High quality engineering thermoplastics make the Lucy Zodion Titan2 range the ideal choice to withstand heavy use in demanding locations.
Lucy Zodion Titan2
Street Lighting Cut Outs Range
- Single or double pole cut outs
- Single or twin fuse cut outs
- Brass or insulated gland plate options
- Extensive trough options
- 1 up, 2 up, 1 up 1 down circuit arrangements

Street lighting Cut Outs – Titan2
TITAN2 SINGLE & DOUBLE POLE CUT OUTS
PRODUCT SPECIFICATION
Should you require any technical support and advise in order to select the correct street lighting cut out please do not hesitate to contact us.
Lucy Cut Out Part No | Fuseways | Components | Description | Cable Entry | Image |
Titan2 (NT06) double pole single fuse cut out, complete with earth block, and brass plate with: | |||||
THM0006032 | 1 | 2 x 20mm grommets | NT06-TT-NG12 | ![]() |
![]() |
THM0010170 | 1 | 2 x BW20 brass glands | NT06-TT-NG18 | ![]() |
|
THM0010121 | 1 | 2 x 20mm tubes | NT06-TT-NG25 | ![]() |
|
THM0031147 | 1 | 2 x 25mm tubes | NT06-TT-NG26 | ![]() |
|
Titan2 (NT06) double pole single fuse cut out, complete with earth block, small extension trough, and brass plate with : | |||||
THM0010657 | 1 | 2 x 20mm grommets | NT06-TT-NEF-NG12 | ![]() |
![]() |
THM0017257 | 1 | 2 x 20mm grommets | NT06-TT-NEF-NG13 | ![]() |
|
THM0013678 | 1 | 2 x BW20 brass glands | NT06-TT-NEF-NG18 | ![]() |
|
THM0010211 | 1 | 2 x 20mm tubes | NT06-TT-NEF-NG25 | ![]() |
|
THM0010212 | 1 | 2 x 25mm tubes | NT06-TT-NEF-NG26 | ![]() |
|
Titan2 (NT06) double pole single fuse cut out, complete with earth block, large extension trough, and brass plate with : | |||||
THM0036546 | 1 | 2 x 25mm grommets | NT06-TT-NED-NG13 | ![]() |
![]() |
THM0037191 | 1 | 2 x 20mm tubes | NT06-TT-NED-NG25 | ![]() |
|
THM0028975 | 1 | 2 x 25mm tubes | NT06-TT-NED-NG26 | ![]() |
|
THM0016546 | 1 | 2 x BW25 glands and 1 x 25mm grommet | NT06-TT-NEE-NG82 | ![]() |
|
Titan2 (NT08) double pole twin fuse cut out, complete with earth block, and brass plate with : | |||||
THM0009901 | 2 | 2 x 20mm grommets | NT08-TT-NG12 | ![]() |
![]() |
THM0012689 | 2 | 2 x BW20 brass glands | NT08-TT-NG18 | ![]() |
|
THM0013303 | 2 | 2 x 20mm tubes | NT08-TT-NG25 | ![]() |
|
THM0014521 | 2 | 2 x 25mm tubes | NT08-TT-NG26 | ![]() |
|
Titan2 (NT08) double pole twin fuse cut out, complete with earth block, small extention trough, and brass plate with : | |||||
THM0010563 | 2 | 2 x 20mm grommets | NT08-TT-NEF-NG12 | ![]() |
![]() |
THM0029334 | 2 | 2 x 25mm grommets | NT08-TT-NEF-NG13 | ![]() |
|
THM0014659 | 2 | 2 x BW20 brass glands | NT08-TT-NEF-NG18 | ![]() |
|
THM0011708 | 2 | 2 x 20mm tubes | NT08-TT-NEF-NG25 | ![]() |
|
THM0010841 | 2 | 2 x 25mm tubes | NT08-TT-NEF-NG26 | ![]() |
|
Titan2 (NT08) double pole twin fuse cut out, complete with earth block, large 2-way extention trough, and brass plate with : | |||||
THM0037298 | 2 | 2 x 25mm grommets | NT08-TT-NED-NG13 | ![]() |
![]() |
THM0037316 | 2 | 2 x 20mm tubes | NT08-TT-NED-NG25 | ![]() |
|
THM0037323 | 2 | 2 x 25mm tubes | NT08-TT-NED-NG26 | ![]() |
|
Titan2 (NT10) double pole twin fuse cut out, complete with earth block, 3-way extension trough, and brass plate, with : | |||||
THM0027135 | 2 | 3 x 25mm tubes | NT10-NED-NEE-NT6-NG61 | ![]() |
![]() |
THM0012093 | 2 | 3 x 20mm grommets | NT10-NEC-NT6-NG68 | ![]() |
|
THM0010786 | 2 | 2 x 25mm grommets, 1 x 20mm grommet | NT10-NEC-NT6-NG52 | ![]() |
Lucy Zodion Titan2
Specifications
Specifications |
|
Options |
|

Lucy DNO Cut Outs Offer Street Lighting Contractors Improved Cable Termination Access
Lucy Lighting Titan SLF
Single Pole Cut Outs
With its low body split line to maximise cabling access, the Lucy Lighting Titan SLF is the simplest exponent of the single pole cut outs.
Tough, engineering grade thermoplastics and fully electroplated brass componentry ensure that the Lucy SLF street lighting cut out will have a long, reliable service life.
The Lucy Zodion Titan MC040SLFÂ cam operated fuse handle ensures that electrical disconnection takes place prior to the fuse carrier being extracted by the street lighting contractor.
Lucy Zodion MC040SLFÂ Single Phase Cut Out Specifications
- Cut out designed and tested in accordance with BS 7654:1997
- 25A maximum fuse rating
- Accepts fuse links to BS 88 Part 1, AC 16 tag type
- IP22 rating
- Single pole isolation
- Single fuse
- Electroplated brass terminals with serrated bores
- Max. cable size; 16sqmm stranded copper, 25sqmm solid aluminium
- Â Cable entry via PVC grommets as standard
- Outgoing cables exit below horizontal to form drip loop
- Sealing wire facility
Lucy Zodion Titan MC040SLF Single Phase Cut Out Dimensions | |
Height | 150mm |
Width | 76mm |
Depth | 60mm |
Order Details For MC040SLF Street Lighting Cut Out | |
Order Code | Description |
MC040SLF 25A SLCO TYPE 1 (SNE) | Separate Neutral and Earth |
MC040SLF 25A SLCO TYPE 2Â (CNE) | Combined Neutral and Earth |
➡ For further information about how Lucy Zodion provide control and power distribution products for street lighting applications, please review the Lucy Titan (Cut-outs) and Lucy Trojan (Isolators) ranges of products.
- Further Reading: Street Lighting Cut Outs From Lucy Zodion – WPD Approved (G81)
Complete range of LV Cable Accessories ➡
Cable Breakouts | Cable Caps | Cable Lugs | Cable Cleats | Cable Trough | Cable Duct | Feeder Pillars | for 11kV/33kV/66kV networks see MV HV Joints & Terminations

Pfisterer | Nexans Euromold | Prysmian | Cable Joints & Terminations MV HV

Cold Shrink by 3M | Joints | Abandonment | Terminations | Low Voltage LV Cables
Further Reading
-
Lucy Zodion Titan2 Street Lighting Cut Outs Selection Guide Size: 80.44 KB