IEC61111 | Class 0 Matting – 1000V Electrical Insulating Rubber Mats IEC61111
Class 0 Matting – 1000V Electrical Insulating Rubber Mats IEC61111
IEC61111
Insulating Matting
Thorne & Derrick | Electrical Matting Distributed from Stocks | UK & Export Sales
Class 0 matting SM570-00 is a high quality fine ribbed rubber insulating matting which is fully certified to meet IEC61111 standards.
The IEC61111 Class 0 matting is fully certified and tested to 10kV with a recommended safety working voltage of 1kV.
Additionally the insulating matting has a fine ribbed, anti-slip surface pattern on one side and a cloth impression finish on the reverse side ensuring safe electrical working conditions for users.
SM570-00 insulating matting is available in cut lengths on request with a thickness of 3mm and widths of 0.91m, 1m and 1.2m.
Class 0 matting in accordance with IEC61111 can also be provided in Grey (SM571-00), Grey/Black (SM572-00) or Red (SM573-01) each cut to length on request.
Features of IEC61111 Class 0 Matting
Our range of Class 0 insulating matting does not contain any recycled rubber proving the highest levels of compliant electrical safety and protection when working around electrical switchgear, control panels and substations. The electrical matting will safely dissipate current leakage reducing the electrocution shock effect of workers standing on the mat.
- REACH RoHS, PAH and CE Compliant EPDM type insulating rubber matting
- Withstand Test – 10kV – No Electrical Puncture
- Puncture Proof Test – 5kV for 3 minutes
- Working Voltage – 1,000 volts
- Matting Thickness 3mm and 6mm
- Halogen free Class 0 matting
- Excellent resistance to acid/alkali
- Full test certificate supplied
- Fully tested to specification
- Health & Safety regulation material
- Fully traceable supply
- Anti-slip finish
- Low maintenance
- Matting is available in 0.91m, 1.0m and 1.2m wide rolls
- Cut lengths of mats available to order
- IEC61111 Tested & Certified Electrical Insulating Matting
Class 0 Matting
Technical Information
SM570-00 to IEC61111-2009 Class 0.
- Mat Withstand Test 10kV – No Electrical Puncture
- Mat Proof Test 5kV
- Mat Working Voltage 1kV
Class 0 Matting Part Number | SM570-00 Insulating Matting |
Insulating Application | Electrical Safety, General Purpose, Health & Safety, Switchboard, Switchgear |
Insulating Matting Product Description | 1kV Working Voltage IEC61111 Class 0 Anti-Slip Electrical Safety Insulating Matting |
Matting Thickness | 3mm Mats |
Colour | Black. Others available on request |
Insert Req | No |
Solid | Yes |
Drainage Holes | No |
Dielectric Test Voltage | 10kV |
Surface Proof Test Voltage | 5kV |
Class 0 Working Voltage | 1kV |
Compound | EPDM |
Hardness (Shore A) | 70º |
SM570-00 to IEC61111-2009 Class 0
The following table excerpts the test performance of Class 0 matting according to Clause 5 of IEC61111 2009.
Clause No. | Properties | Specification |
|
– | Specific Gravity | 1.50 ± 0.05 | |
– | Hardness, Shore A | 75 ± 5 | |
– | Tensile Strength, Kg/cm2 | 50 Min. | |
– | Elongation at Break, % | 200 Min. | |
– | Colour | Black | |
– | Surface Finish | Fine rib with fabric finish | |
Electrical Properties |
|||
5.5 | MECHANICAL TESTS | ||
5.5.2 | Mechanical Puncture Test | Min 70N | |
5.5.3 | Slip Resistance | Avg. force higher than 50N | |
5.6.2.2 | Class | Proof Test | Withstand Test |
5.6.2.3 | Class – 0 (Thickness 3.0 mm and 6mm ) | 5KV for 3 minutes | 10 KV – No electrical puncture |
5.7 | Ageing Test At 70 ± 2oC/168Hrs | ||
Mechanical Puncture Test | Should be minimum 80% of original value | ||
5.8 | Thermal Properties | ||
5.8.1 | Flame Retardance | Flame should not propagate within a 50mm diameter from the centre | |
5.8.2 | Low Temperature Resistance (4hr at -25 ± 3oC) | ||
a) Visual Inspection | No cracks | ||
b) Voltage withstand | No electrical puncture |
See other types of Matting | BS921 | 11kV | 33kV | ASTM D178 | Fire Rated
International Standard IEC61111:2009
The International Standard IEC6111:2009 outlines the requirements for rubber insulating matting for electrical purposes and specifies the construction materials, thickness, width and the testing conditions and results expected to meet the standard.
IEC 61111:2009 is applicable to electrical insulating matting made of elastomer for use as a floor covering for the electrical protection of workers on electrical installations. This second edition cancels and replaces the first edition, published in 1992, and its Amendment 1 (2002). This edition constitutes a technical revision. It includes the following significant technical changes with regard to the previous edition:
- general review of the requirements and test provisions;
- modification of the test procedure for slip resistance;
- preparation of the elements of evaluation of defects, and general application of IEC 61318 Ed.3;
Contact T&D for prices, delivery and technical support for SM570-00 1kV IEC61111 Class 0 Electrical Mats.
➡ See also Class 1 Matting | Class 2 Matting | Class 3 Matting | Class 4 Matting
MV-HV insulating matting also available for safe working on medium/high voltage switchgear/switchboards up to 33kV.
Insulating Matting | Electrical Safety & Protection for Low, Medium & High Voltage Switchgear
CATU Electrical Safety MV HV
T&D stock and distribute the complete range of CATU Electrical Safety Equipment.
CATU offer a range of Arc Flash Clothing For High Voltage Utility Cable Jointers & Lloyds NERS LV-HV Electrical Contractors
Voltage Detectors | Phase Comparators | Insulating Poles | Portable Earthing | LV MV HV