Pot End Live Cable End Seals 11kV HV High Voltage Cables 3 Core XLPE EPR

Cable Abandonment | Pot End Cable End Seals | Energised or Dead Cables 11kV

Complete range of cable abandonment kits and live pot end sealing kits for : 11kV HV High Voltage Cables 3 Core XLPE EPR.

Suitable to provide 11kV Pot End Sealing of all types of 3 core polymeric insulated cables XLPE/EPR with copper tape screen and wire braid (PSWB GSWB) or wire armour (SWA).

For 600/100V power cable systems see Live Pot End Kits for LV power systems.

Kits also available for: 11kV HV High Voltage Cables Single Core XLPE CWS (Copper Wire Screened).

âž¡ Joints | Terminations 11kV 33kV Heat Shrink

11kV

Installation Video: High Voltage Pot End Live Cable End Seals 

Submersible Cable Repair

Cable: Hydrocable Systems Ltd

  • uploaded by Chris Dodds - Thorne & Derrick Sales & Marketing Manager


Cable Repair

Harsh Environment, Hazardous Area & Offshore Cable Repairs

3M Electrical

Thorne & Derrick distribute cable repair products to enable the effective re-instatement of cable sheath damage to all types of onshore and offshore LV Low Voltage, MV Medium Voltage & HV High Voltage cables.

The zero halogen flame retardent polyurethane cable sheath suffered service damage in an offshore location (non-hazardous) providing low voltage power to critical submersible firepumps – the sheath required repair to prevent seawater ingress into the cable which would cause severe corrosion to the wire braided cable and compromise the electrical insulation levels and operability of the firewater cables, pumps and fire protection system.

With an outside diameter of 21.7mm around the cable sheath the 3M 82F2 cable joint with a range-take of 20-30mm cable diameters were specified and supplied by Thorne & Derrick to effect the cable repair. Where significant damage is inflicted into the cable sheath, wire braid armour or insulation (EPR XLPE) a complete submersible cable joint can be provided.

The cable repair solution features seawater resistant and flexible 3M Scotchcast 2131 resin which provides stable performance in offshore seawater exposed locations without comprising the flexibility of cable circuit.

Basically, a wraparound mould is placed onto the cable to cover the nick to the sheath and then encapsulating Scotchcast resin is poured into the joint mould to achieve both electrical insulation and mechanical protection to the cable.

Repair & Joint Submersible CablesCable Joint

Thorne & Derrick International, based in the UK, distribute an extensive range of Offshore Cable Joints to suit halogen free (zero halogen), flame retardant, MUD resistant, heat resistant and fire resistant offshore and shipboard power, control and instrumentation cables.

Cable Repair

Cable Repair Systems | Cold Shrink Tubes | Heat Shrink Wraparound

Pfisterer CONNEX

  • uploaded by Chris Dodds - Thorne & Derrick Sales & Marketing Manager 

Meet Mohamedali – he has been working as a Cable Jointer since 1985.

During this period he has worked with various companies namely Fujikura Ltd, Furukawa Electrical, Taihan Electrical, Sumitomo Electrical and many others organisations in countries such as Japan, Singapore, Kuwait, Qatar, Saudi Arabia, Korea and India.

Mohamedali has had the opportunity to work on prestigious projects jointing and terminating cables including 132kV, 275kV 300kV and 400kV oil filed and XLPE type cables.

Today, Mohamedali is a proud Pfisterer CONNEX Certified Jointer working throughout the Middle East on HV & EHV Electricity & Substation projects.

The following photographs display the experience and workmanship of Mohamedali.

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

 

Pfisterer CONNEX

Pfisterer CONNEX

 

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

 

Pfisterer CONNEX

Pfisterer CONNEX

Pfisterer CONNEX

 

Pfisterer CONNEX

Pfisterer CONNEX

 

Pfisterer CONNEX

CONNEX & SEANEX

  • uploaded by Chris Dodds - Thorne & Derrick Sales & Marketing Manager

Class 1 & 2: Shows the obligatory number of strands
Class 5 & 6: Shows the maximum strand diameter, may be fewer strands as long as the maximum ohms/km is not exceeded
Ohms Ω/km: Shows the maximum resistance in that is permissible for untinned copper conductors in the stranding classes indicated

Area sqmm Stranding Class 1
Stranding Class 2
Ohms Ω/km
Stranding Class 5
Stranding Class 6
Ohms Ω/km
0.14 18 x 0.10 18 x 0.10 138.0
0.25 14 x 0.16 32 x 0.10 79.0
0.34 19 x 0.16 42 x 0.10 57.0
0.5 1 x 0.80 7 x 0.30 36.0 16 x 0.21 28 x 0.10 39.0
0.75 1 x 0.97 7 x 0.37
24.5 24 x 0.21 42 x 0.16 26.0
1.0 1 x 1.13 7 x 0.43 18.1 32 x 0.21 56 x 0.16 19.5
1.5 1 x 1.38 7 x 0.53 12.1 30 x 0.26 84 x 0.16 13.3
2.5 1 x 1.78 7 x 0.67 7.41 50 x 0.26 140 x 0.16 7.98
4.0 1 x 2.26 7 x 0.85 4.61 56 x 0.31 224 x 0.16 4.95
6.0 1 x 2.76 7 x 1.04 3.08 84 x 0.31 192 x 0.21 3.30
10.0 1 x 3.57 7 x 1.35 1.83 80 x 0.41 320 x 0.21 1.91
16.0 1 x 4.51 7 x 1.70 1.15 128 x 0.41 512 x 0.21 1.21
25.0 7 x 2.14 0.72 200 x 0.41 800 x 0.21 0.78
35.0 7 x 2.52 0.524 280 x 0.41 1120 x 0.21 0.554
50.0 19 x 1.78 0.387 400 x 0.41 705 x 0.31 0.386
70.0 19 x 2.14 0.268 356 x 0.51 990 x 0.31 0.272
95.0 19 x 2.52 0.193 485 x 0.51 1340 x 0.31 0.206
120 37 x 2.03 0.153 614 x 0.51 1690 x 0.31 0.161
150 37 x 2.25 0.124 765 x 0.51 2123 x 0.31 0.129
185 37 x 2.52 0.099 944 x 0.51 1470 x 0.41 0.106
240 61 x 2.25 0.074 1225 x 0.5 1905 x 0.41 0.081
300 61 x 2.52 0.060
400 61 x 2.85 0.046
500 61 x 3.20 0.036

 

LV, MV & HV Jointing, Earthing, Substation & Electrical Eqpt

Thorne & Derrick International are specialist distributors of LV, MV & HV Cable Installation, Jointing, Duct Sealing, Substation & Electrical Equipment – servicing UK and global businesses involved in cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV.

THORNE & DERRICK Product Categories: Duct Seals | Cable Cleats | Cable Glands | Electrical Safety | Arc Flash Protection | Cable Jointing Tools | Cable Pulling | Earthing | Feeder Pillars | Cable Joints LV | Joints & Terminations MV HV 

Thorne & Derrick International

66kV Training

  • uploaded by Chris Dodds- Thorne & Derrick Sales & Marketing Manager

66kV XLPE Cables

Jointer Training & Tools

Thorne & Derrick are Specialist Stockists & Distributors of cable joints and terminations for 66kV power cables – this includes the provision of 66kV Jointer Training using Nexans Power Accessories UK facility. To support the installation of 66kV joints, terminations and connectors we stock and distribute a full range of Jointers Tools to enable the preparation of all critical stages of the cable stripping process – this includes removal of cable sheath, insulation XLPE, lead sheath and bonded semicon screens.

Manufacturers of cable preparation tools provide competing options in the design, functionality and application of their cable tools – it is usually a mixture of cable jointers personal preference and client approval which informs the tool selection process, nevertheless the following information provides guidance and some recommendations for tools to use when stripping 66kV cables.

Can I Use Standard 33kV Tool Sets To Prepare 66kV Cables?

Yes, but…..

Although 66kV is classed as high voltage, due to the construction diameters of 66kV cables often 33kV medium voltage cable preparation tools can be used – for the Nexans Jointers Training Courses the standard MV cable tools are compatible with the training cable up to 300sqmm at 66kV.

However, for future 66kV projects it would be necessary for the jointer to upgrade their tool set to enable the preparation of larger diameter cables above 300sqmm conductors.

Naturally, when using medium voltage category tooling there will be a requirement for the cable jointer to undertake additional glassing of the XLPE insulation to achieve the required chamfer prior to installing the MV HV joint, termination or connector.


Cable Jointing Tools

Cable Jointing Tools | 66kV IAC Inter-Array Cables

US02 MAX | here the Jointing Tool is shown here in use on the high voltage cable preparation of 66kV/72kV 1200sqmm single cable XLPE insulation with bonded semicon screen – minimal polishing and chamfering required with a clean and precise transition.


Cable Sheath & Lead Sheath Removal

Typically, Alroc cable sheath stripping pliers, PG types, would be used for removal of the outer cable sheath/jacket depending on the outside diameter of the cables to be jointed and terminated – these tools effectively strip the PE (polyethylene) sheath from medium/high voltage power cables. The lead sheath (Pb) is generally removed using jointers knives – the lead sheath should be carefully scored and then peeled from the cable.


Cable Insulation & Bonded Screen Removal

Note for larger diameter 66kV power cables, 300sqmm+, the standard 33kV cable preparation tools will be unsuitable – for removal of XLPE insulation with bonded screens we would recommend Alroc CAMF4/40-90 tool.

The 66kV Training Course utilises single core 300sqmm cables with a 48.1mm diameter over the bonded semicon screen – depending of jointers preference any semicon shaving tool from reputable manufacturers including Alroc, Ripley or Boddingtons could be used.

Similarly, any XLPE cable insulation removal tool suitable for 46.1mm primary insulation diameter cable could be used.

The preferred bonded screen stripping tool is used to leave various lengths of black insulation screen from the outer sheath cut and the measurement varies depending on the type of joint, termination or connector.

Cable Jointing Tools

Chamfer | Groove | Shave – Alroc CAMF4/40-90-BBCF Multi-function 66kV Cable Tool


Chamfer & Polish

Aluminium Oxide

Aluminium Oxide

For the chamfer we would recommend the Alroc GRI tool along with conventional glass to achieve a smooth finish to the XLPE insulation – the cable insulation would then be polished using aluminium oxide abrasive strips, usually 180/240 grit and 400 grit.

The XLPE insulation must be polished smooth with an appropriate aluminium oxide grit paper until the XLPE surface is smooth and wrinkle-free. To finish this process, reverse the paper and “buff-up” with the smooth side.

Alroc GRI

Alroc GRI Tool


Cable Sanding Machines & Tools for MV HV Cables up to 130mm Diameter

Reducing Repetitive Strain & Improving Cable Preparation Processes


Typically 66kV Cable Specification

âž¡ The following cable specification is based on 66kV XLPE Insulated Lead Sheath Single Core 300sqmm cable to IEC 60840:

Single Core Cable with Copper Round Compacted Conductor, XLPE Insulated, Lead Sheath, Polyethylene Oversheath
66kV Cable Code 714242019533**
Standard Specification IEC 60840 Generally according to NPS/002/022
Type of Cable XLPE/PB/MDPE
Rated Voltage Uo/U (Umax) 38/66 (72.5kV)
Number of Cores x Nominal Cross-section 1 x 300sqmm
Approximate Cable Overall Diameter  59mm
Approximate Cable Overall Weight  8.4kg/m
Nominal Drum Length (Tolerance) 500m (-0%, +0%)

Cable oversheath marking by embossing in two lines as follows:

  • CABLEL 0317 2016 09* ELECTRIC CABLE 66000 VOLTS IEC 60840 1×300 CU ‘ref number’**
    *Year and month of manufacture
    ** Insulation Core Lot number (8 digits by embossing and 2 last digits by indenting)
  • By ink – meter marking at on metre intervals

66kV Cable Structure

Cable Manufacturer Hellenic Cables S.A.

Cable Structure

  1. Conductor:
    Annealed bare copper round strand compacted class 2 BS EN / IEC 60228 of nominal cross-section equal to 300sqmm longitudinally waterblocked by waterblocking yarns and/or waterblocking tapes and/or waterblocking powder between conductor inner strands (approx diameter over 20.4mm)
  2. Semiconductive tape applied helically with overlap
  3. Conductor non-metallic extruded screen:
    Extruded semiconducting compound of 1.0mm nominal thickness (0.60mm minimum at any point thickness)
  4. Insulation
    XLPE super-clean according to IEC 60840 of 12.0mm nominal thickness (minimum average thickness of 11.0mm, minimum at point thickness 10.80mm – approx diameter over insulation 46.1mm)
  5. Core non-metallic extruded screen:
    Extruded semiconducting compound bonded to insulation of 1.0mm nominal thickness (0.60mm at any point of thickness)
  6. Semiconductive waterblocking tape applied helically with overlap
  7. Metallic sheath:
    Lead alloy type PK021S or other suitable alloy type according to EN 50307 of 2.0mm nominal thickness
  8. Cable sheath
    MDPE type ST& according to IEC 60840 of 2.7mm nominal thickness.
    Sheath colour: Black
  9. Extruded semiconducting compound serving as electrode for the DC voltage test of the oversheath

Cable Terminations

Pfisterer CONNEX | 3M Cold Shrink | Nexans Euromold | Nexans Slip-on | Heat Shrink Cable Terminations – stocked and distributed by Thorne & Derrick


Cable Innovation Tools & Accessories for Low & High Voltage Power Systems

THORNE & DERRICK are Specialist Distributors of LV HV Cable Jointing, Earthing, Substation & Electrical Eqpt up to 66kV – this includes the most extensive range of Ex Stock Innovation Tooling to facilitate safe and reliable preparation, termination and installation of cables.

THORNE & DERRICK are Specialist Distributors of LV HV Cable Jointing, Earthing, Substation & Electrical Eqpt up to 66kV – this includes the most extensive range of Ex Stock Innovation Tooling to facilitate safe and reliable preparation, termination and installation of cables.

Blog

Voltage Detectors Explained: Types, Uses & Safe Voltage Testing

Published 16 Nov 2026

Voltage Detectors Explained: Types, Uses & Safe Voltage Testing

Voltage detectors are electrical safety instruments used to identify the presence or absence of voltage on electrical equipment and conductors. They are used by electricians, electrical engineers, utilities and maintenance teams working on low voltage (LV), medium voltage (MV)...

Read More

Associated manufacturers
Share this page
Share this page
X

Get a quote

Complete the form below to make an enquiry about products.

  • This field is for validation purposes and should be left unchanged.
  • Please enter your full name.
  • Please enter your contact telephone number.
  • Please enter your e-mail address.
  • Please select if you are enquiring about products for the UK or for export.