HYDRAULIC PUNCHING TOOLÂ – INCLUDES A set of punches ISO 16-40
The LS 50 FLEX is a battery powered hydraulic punching tool with a highly flexible rotating head and an integrated pressure sensor which increases the service life of the hole punch.
The LS 50 FLEX has an automatic stop allowing the punching tool to last longer than competitors.
Since 1996, Klauke has expanded its product portfolio with the Greenlee brand. With the focus on punching tools and cable management products.
Thorne & Derrick, specialist distributors of Klauke cable crimping and cutting tools, are offering the LS 50 Hydraulic Punching Tool + a set of punches ISO 16-40, at the discounted price of £1,250. ex. delivery & VAT. Contact us to place your order.
Klauke LS 50 FLEX
LS 50 Cable PUNCHING TOOL FEATURES
Choose your battery system: Bosch or Makita
All data can be easily read via Bluetooth
Balanced centre of gravity for easy handling and effortless operations
LED for work area illumination
Energy saving function with motor cut-out after successful operation
Manual retract as required
Always ready-to-use thanks to battery charge and service display
LS 50 Flex Punching Tool Kit Contents
This special offer bundle includes the LS 50 Flex, as well as the Slug Buster® SetISO 16 – 40 for quick, clean, effortless and burr-free holes. The Slug Buster® set is suitable for mild steel up to 3.5mm thick material.
The Slug Buster has a unique design which splits the produced slug into two parts, making removal quick & easy, and immediately ready for the next hole.
A slug split into 2 parts
The cable punching tool, as well as the Slug Buster punch set, is used extensively by Panel Builders and Electrical Contractors; perfect for enclosures & gland plates. The set reduces noise & vibration compared to hole-saws, to create exact sized holes with minimal swarf and no-deburring.
Ls 50 Cable Punching Tool Specification
The LS50Flex hydraulic punching tool can be used for stainless steel material, square and rectangular holes.
Should you require technical support, product information or a UK demonstration of the LS 50 Cable Punching Tool please do not hesitate to contact us.
Hydraulic Punching Tool Klauke LS 50 FLEX BATTERY Powered
The Orange range of insulated tools is a technology advance in the development of battery-powered cabling tools for the cutting and crimping of overhead lines and underground cables.
Thorne & Derrick International are specialist distributors of LV, MV & HV Cable Installation, Jointing, Duct Sealing, Substation & Electrical Equipment – servicing UK and global businesses involved in cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV.
ProGARM produces safety garments that protect workers against the Thermals Hazards of an Electric Arc. Each arc flash protective garment is carefully designed by ProGarm to offer the maximum protection to the new arc flash standard IEC 61482 whilst ensuring comfort and outstanding durability.
As Arc Flash clothing items come under the requirements of Category 3 Protective Clothing, these garments are manufactured under Module D Quality Control Procedures.
WHAT IS AN ELECTRIC ARC?
Electric Arc and the arc flash created is the light and heat produced as part of an arc fault; a type of electrical explosion or discharge that results from a low impedance connection through air to ground or another voltage phase in an electrical system.
The intense heat can create temperatures as high as 19,000°C and it also produces electric shock, force and large quantities of thermal radiant energy.
What is the Risk?Â
In any situation where your employees are working with electricity, an Arc Flash can occur and as such the maximum energy of default circuits in any electrical installation must be able to be determined. The risks of an electric arc exposure are:
Electrocution – potentially fatal
Extremely high levels of Radiant Heat
1st, 2nd or 3rd Degree burns – 3rd Degree burns cause permanent damage
Performance requirements for materials and design requirements for garments, plus Marking and User Information.
This part of IEC 61482 is applicable to protective clothing used in work if there is an electric Arc hazard. This standard specifies requirements and test methods applicable to materials and garments for protective clothing worn by electrical workers to protect them against the thermal hazards of electric Arc based on relevant general properties of the textiles, tested with selected textile test methods, and one of the Test Methods as defined below.
IEC 61482-1-1:2019 ‘OPEN ARC’ TEST METHOD
‘Open Arc’ test method (ATPV test and garment test). This replaces IEC 61482-1:2002. The ‘Open Arc’ test method is the same as the original North American method for measuring the Arc Thermal Performance Value (ATPV), as used in ASTM F1959. Materials or assemblies are given an ATPV/EBT/ELIM value, expressed in kilojoules per square metre (kJ/m2), which can be converted into the familiar cal/cm2.
Or
IEC 61482-1-2:2007 ‘BOX ARC’ TEST METHOD
‘Box Arc’ test method (Fabric classification and garment test). The ‘Box Arc’ test method is based on the original European method described in ENV 50354, with a heat transfer measurement. Materials or assemblies are classified as Arc Protection Class (APC) 1 (4 kA) or APC 2 (7kA).
During this test, a fabric sample is exposed to an electric Arc produced by a 4kA or 7kA short circuit. In the test, the Arc does not last any longer than 500ms. The amount of heat transmitted through the sample is measured during and after the test. On the basis of the resulting data and a Stoll curve, the length of time it would take to cause the onset of second-degree burns is subsequently determined. Samples are also assessed for after-flaming, hole formation, melting, etc.
GARMENT TESTING & FABRIC TESTING
It is important to note that not only the fabric should be tested for conformance to the Arc Flash Standard, but also the complete garment or garment assembly itself.
The garment test is not testing for energetic value but is testing to ensure that the garment structure remains intact after the Arc exposure and that components such as zippers and buttons are still functional and do not contribute further injury to the wearer by melting or heat transfer.
ProGARM | Functional Arc Flash Clothing, Protection & PPE For Everyday Wear
As a result of this ProGARM have written a short guide to the new IEC 61482-2:2018 standard to highlight the key bits of information you need to be aware of when reviewing your PPE specification and the key terminology that you need to understand.
Choosing the right PPE for your team can be difficult and with all the standards to consider it can feel quite overwhelming. This guide aims to help people make a more informed decision about what PPE is best for you.
You can download the PDF guide via this link or see the attached pdf below.
We can help – should you require arc flash calculators or advice on the type of clothing and protection available please do not hesitate to contact us.
Thorne and Derrick are proud to be distributors of ProGARM arc flash coveralls and protection.
We can help – should you require arc flash calculators or advice on the type of clothing and protection available please do not hesitate to contact us.
Thorne & Derrick are national distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment – servicing businesses involved in cabling, jointing, substation, earthing, overhead line and electrical construction at LV, 11kV, 33kV, 66kV and EHV. Supplying a complete range of power cable accessories to support the installation and maintenance of low/medium and high voltage power systems:
Learn more about Cable Jacket Repair by signing up to the webinar
Damage to the Cable Jacket & Sheath is a fairly common issue on site.
A cable might be endangered even before deployment: for example, a cable may have been dragged across a concrete floor and snagged. When the Cable Sheath is damaged, the electrical system may become compromised from moisture and contaminants. Even the smallest scratches can be dangerous as they can be deeper than they appear and increase when bending the cable. This is why Cable Jacket Repairmethods are paramount.
cable jacket RepaiR
With 3M
Cable Jacket Repair with 3M Electrical Tapes
3M Electrical tapes are the robust and convenient solution to repair cable jacket damages in the field.
Tape fits all cable sizes—no need to keep the big range of materials on stock—just a couple of rolls in your toolbox.
Repair with tapes doesn’t need fire or heating. It’s convenient for work in confined spaces, and in most cases, it’s a durable and economically efficient solution. 3M electrical tapes can be used for both temporary and permanent repair.
The nature and type of damage to a cable determines which selection of tapes and methods of repair should be used. The tapes may be used to repair scratched or slightly damaged cable jackets, or more substantial repairs; where a section of the cable jacket is missing. Where the conductor or inner parts of a cable’s construction is not damaged, the repair of the cable jacket is possible with the use of 3M tapes. Otherwise, if these parts are damaged, the cable would have to be either splicedor replaced.
3M Tapes for Cable Jacket Repair
In the following circumstances, methods of Cable Jacket repair from 3M, including 3M Scotch Electrical Tapes, can be used
For PVC and Rubber cables, low and medium voltage
For single- or multi-conductor cables
For damages which don’t penetrate to conductor depth
Cable JAcket & Sheath Repair Methods
The different levels of cable damage are demonstrated below: with the suggested repair methods for each.
Damage Level 1
Damage Level 2
Damage Level 3
Minor damages.Surface damages like scratches and grooves from sharp edges.
More substantial damages with cable cores intact. Cuts and breakouts of the cable jacket.
A new cable splice is required. Severe damageswith damages cable cores. Punctures and deep damages affecting the inner layers of the cable. Further detection of the cable is necessary.
3M Electrical tapes for cable jacket repair
Rubber Mastic tapes, manufactured by 3M, are the main components of cable jacket repair solutions. These flexible tapes go on smoothly and bond instantly to make electrical repairs in the field an easy task. A mastic adhesive securely adheres to most power cable jacket materials without loosening or separating, delivering a reliable seal that will maintain the integrity of the cable jacket in the long term.
3M Scotch 2234 Tape is designed specifically to repair damages on the cable jackets.
The outer layer of this tape is composed of vulcanised CSM rubber to provide outstanding resistance to abrasion, chemicals, tearing, and cut-through.
Max Temperature: 105°C / 221°F
Alternative solutions for minor damage repairs
Besides Scotch® Cable Jacket Repair Tape 2234, 3M provides alternative tapes solutions for Cable Jacket repairs with different characteristics. See the table below with the different options.
1
1. Wrap Scotch® Rubber Mastic Tape 2228 over the scratch.
2. Then overwrap with Scotch® Super 33+™ Vinyl Electrical Tape over the whole repair length for the mechanical strength.
Scotch® 2228 is softer then Scotch® 2234, it’s not flame retardant and has lower chemical resistance vs. Scotch® 2234.
2
1. Wrap Scotch® Rubber Mastic Tape 2228 over the scratch.
Very similar characteristics to Scotch® 2234, but even more hard. It was specially designed for the Mining industry.
Alternative solutions for substantial damage repairs
Similar to the repair of minor damages, there are alternative solutions to Scotch 2234 tape for substantial damage repairs.
1
1. 3M™ Scotchfil™ Electrical Insulation Putty into the hole for sealing and moisture protection and restoring the mechanical properties of the cable.
2. Scotch® Rubber Mastic Tape 2228 over the whole repair length.
3. Scotch® Super 33+™ Vinyl Electrical Tape on top for mechanical strength.
Scotch® 2228 is softer then Scotch® 2234, it’s not flame retardant and has lower chemical resistance vs. Scotch® 2234.
2
1. 3M™ Scotchfil™ Electrical Insulation Putty into the hole for sealing and moisture protection.
2. 3M™ Scotchfil™ Electrical Insulation Putty over the whole repair length.
3. Scotch® Super 33+™ Vinyl Electrical Tape on top for mechanical strength.
Only 2 tapes are needed, cheaper option. 3M™ Scotchfil™ is not as easy to apply as Scotch® 2228.
3
1. 3M™ Scotchfil™ Electrical Insulation Putty into the hole for sealing and moisture protection.
2. Scotch® Rubber Splicing Tape 23 over the whole repair length.
3. Scotch® Heavy Duty Vinyl Electrical Tape 22 on top for mechanical strength.
Scotch® 23 makes the repair place smoother due to its strong radial pressure.
Thorne & Derrick International are specialist distributors of LV, MV & HV Cable Installation, Jointing, Duct Sealing, Substation & Electrical Equipment – servicing UK and global businesses involved in cable installations, cable jointing, substation, overhead line and electrical construction at LV, 11kV, 33kV and EHV.
Wise Wong levitating like a shaman Jointer watchful over O’Malley Snr & Jnr feeling the fire burning and adrenalin rushing through their veins like current through cable.
Subscribe now to our POWER NEWSLETTER– a monthly email circulation packed with news, projects, videos, technical tips, training information, promotions, webinars, career opportunities and white papers.
Includes access to our popular JOINTERS BLOG with contributions from utility professionals, linesmen and cable jointers working on MV HV EHV cables and overhead lines typically at 11kV, 33kV, 66kV and up to 132kV.
15,000+ Subscribers. âž¡
25kV Live Line Voltage Indicators
Network Rail | PADS Approved | PADS Number 0091/012337
The Network Rail Approved C31 Live Line Indicator is designed for use upon overhead a.c. rail electrification systems operating at 25kVnominal voltage to indicate the presence of extra high voltages to aid safe working practices.
C31 Live Line Voltage Indicator Kit Includes
Live Line Indicator
HV Probe and Hook
8mtr Arctic Orange 50sqmm Alufex Lead
J117 Rail Clamp
Battery Charger
C31 Live Line Indicator Kit | Network Rail Approved
Voltage Indicator PRODUCT FEATURES
Dual Independent Circuitry
Automatic Meter Prover
Triple Resistor Set
The 25kV Live Line Indicator incorporates a number of important safety features, including Dual Independent Circuitry. This means that the analogue meter and the LED indicators work completely independent of each other. If one circuit fails, the other will keep on working for your safety.
An Automatic ‘Meter Prover’ operates every time the tester is turned on, proving the electrical and mechanical operation of the analogue meter.
Triple Resistor Sets ensure that the remaining resistors are sufficient to safely protect the operator and the equipment, in the unlikely event of one HV resistor failing.
The resistors are tested at 40 KV AC.
The 50sqmm Aluflex grounding cable will safely conduct the full force of the OHL system in the event of a catastrophic failure of the equipment, such as direct contact with the overhead line.
Automated Test Cert Validation, warning lights flash when test certificate has expired.
The C31 Live Line Voltage Indicator kit comprises the following:
the live line indicator, which comes in a tough protective carry case
a high voltage probe and hook – shrouded for use in wet weather
an 8 metre length of 50mm2 aluflex cable with a rail clamp.
battery charger for charging the C31’s internal Nickel Metal Hydroxide batteries.
Range
0-40kV ac
LED change over
11kV ± 500V
Test duration
<25kV 10 mins > 25kV 1 min
Absolute Max. Rating
40kV ac
Accuracy
Analogue 2%
Analogue Op. Temp
-40c to +70c
LED Op. Temp
-10c to +50c
Seal Rating
Tester body IP65, Probe and gauge IP68
Further technical details:
For use upon overhead a.c rail electrification systems at 30kV nominal voltage.
12kV +/- 5% Threshold voltage. Compatible with standard Westminster operating poles and Primary Insulator pole.
Thorne & Derrick supply an extensive range of 400V-33kV Rail Cable Accessories & Power Distribution Sytems including feeder pillars to contractors undertaking Low Voltage Power Distribution, HV Electrification & Substations, DC Traction & Networks, OLE and Track Feeder Cable Renewals– a complete range of Network Rail PADS approved track terminations, cable joints, cable repair and connection products up to 25kV, including 3M Cold Shrink, Pfisterer CONNEX and Nexans Euromold products.
INDUSTRIAL LABEL PRINTING SOLUTIONS When clear, durable and professional identification is required across control panels, cable systems, production facilities and industrial installations, print quality, reliability and ease of use are critical. Cembre industrial label printers are designed to support...
HIGH VOLTAGE JUNCTION BOXES & ENCLOSURES When high-voltage power distribution and cable termination are required, safety, enclosure integrity and long-term reliability are critical. HV Junction Boxes and Electrical Enclosures manufactured by Abtech are engineered for the safe distribution, cable termination and protection...