Cable For Variable Frequency Drives (VFD’s), RFOU-VFD 0.6/1(1.8/3)kV With Flexible Conductors Class 5 & Separate Earth Cores

Prysmian Draka Cables

Prysmian Draka Offshore Cables – LV, MV & HV (RFOU BFOU to IEC / NEK 606

Prysmian draka cABLES

RFOU-VFD 0.6/1(1.8/3)kV Cable

Offshore Cables

Operating Temperature : 90°C

Operating Voltage : 0.6/1(1.2)kV

Prysmian Draka RFOU-VFD Offshore Cable Applications

Cable nek ts 606

Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606.

CABLE CORE IDENTIFICATION
  • The three main power cores: Brown – Black – Grey
  • All three Earth cores: Yellow/green
RFOU-VFD Cable Construction Code Letter RFOU-VFD Cable Description
Conductor Tinned, annealed, flexible copper, IEC 60228 class 5.
Insulation R Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Lay up 3 insulated phase-conductors are laid up with 3 insulated earth conductors.
Bedding F Flame retardant halogen-free thermoset compound
Cable armour/screen O Cu/PETP-tape Tinned copper wire braid PETP-tape Shield coverage is 100%
Cable outer sheath U Flame retardant halogen-free thermoset compound, SHF2 (IEC 60092-360).
Marking text E.g; ”meter” ”DRAKA 01 RFOU – VFD 0,6/1(1,8/3)kV 3  95 + 3 x 16 mm² IEC 60332-3-22
Outer sheath colour Black or Yellow
Cable Standards Applied
Cable Terminations Joints Cleats 6.6kV 11kV 33kV

Cable Joints, Terminations, Glands & Cleats – available for 6.6kV 11kV and 33kV medium voltage (MV) power cables.

  • IEC 60092-353 – Design IEC 60228 class 2 – Conductor
  • IEC 60092-360 – Insulation IEC 60092-360 – Sheath
  • IEC 60332-1-2 – Flame Retardant
  • IEC 60332-3-22 – Flame Retardant
  • IEC 60331-1, -2, -21 – Fire Resistant
  • IEC 60754-1,2 – Halogen Free
  • IEC 61034-1,2 – Low Smoke
Cable Joints Cable Cleats Cable Glands - Prysmian Cables

T&D distribute the complete range of Prysmian cable cleats, cable joints and cable glands for onshore and offshore LV-HV power, control and instrumentation cables.