Flame Retardant Optical Fibre Cable, AICI-I/O/RM-W, F6

Prysmian Draka Cables

Prysmian Draka Offshore Cables – LV, MV & HV Flame Retardant Optical Fibre (RFOU BFOU to IEC / NEK 606)

Prysmian draka cABLES

AICI-I/O/RM-W, F6 Cable

Fire Retardant Optical Fibre Offshore Cables

Flame Retardant Optical Fibre Cable, AICI-I/O/RM-W, F6

Flame Retardant Optical Fibre Cable, AICI-I/O/RM-W, F6

The outer sheath is made from black UV-stabilized and weather resistant material which is SHF1 classified, and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1.

Prysmian Draka Offshore Cable Applications

Flame Retardant Optical Fibre Cable nek ts 606

Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type. The outer sheath is BLACK.

Flame Retardant Optical Fibre Cable Core Identification
Fibre number Colour Fibre Number  Colour Fibre Number  Colour
1 White 9 Violet 17 Blue + marker
2 Red 10 Turquoise 18 Grey + marker
3 Yellow 11 Orange 19 Brown + marker
4 Green 12 Pink 20 Light Blue + marker
5 Blue 13 White + marker 21 Violet + marker
6 Grey 14 Red + marker 22 Turquoise + marker
7 Brown  15  Yellow + marker 23 Orange + marker
8 Black  16 Green + marker 24 Pink + marker
Flame ReTardant Optical Fibre Cable Properties
Tensile Strength (IEC 60794-1-2E1)
Max tensile load during installation 1700 N
Max tensile load during operation 750 N
Crush (IEC 60794-1-2E3) 2000 N/10cm
Impact (IEC 60794-1-2E4) 1 impacts, 25J
Torsion (IEC 60794-1-2E7) ±1 turn/1m
Cable Bending
Minimum bending diameter 15x outer diameter
Cable bend (IEC 60794-1-2E11) <0.5dB/ ±5 turn
Flexibility (IEC 60794-1-2E8) 1000 cycles
Temperature Window
Operation 40°C to +70°C
Installation -10°C to +70°C
Storage 40°C to +70°C
Water tightness* (IEC 60794-1-2F5B) < 3 m/24 hours
Chemical Resistance
Mineral oils IRM 902 (IEC60811-2-1) – 7 days/23°C
– 4 hours/70°C
Diesel – IRM 903 (IEC60811-2-1) – 7 days/23°C
– 4 hours/70°C
Fire & Smoke Classifications
IEC 60332-1
IEC 61034
IEC 60332-3-22 (Cat. A)
IEC 60332-3-24 (Cat. C)
IEC 60754-1
IEC 60754-2
Cable Terminations Joints Cleats 6.6kV 11kV 33kV

Cable Joints, Terminations, Glands & Cleats – available for 6.6kV 11kV and 33kV medium voltage (MV) power cable

Cable Joints Cable Cleats Cable Glands - Prysmian Cables

T&D distribute the complete range of Prysmian cable cleats, cable joints and cable glands for onshore and offshore LV-HV power, control and instrumentation cables.