Hydraulic & Turbine Oils Resistant, Instrumentation Cable BFOV(i) 150/250(300)V

Prysmian Draka Cables

Prysmian Draka Offshore Cables – LV, MV & HV Instrumentation (RFOU BFOU to IEC / NEK 606)

Prysmian draka cABLES

BFOV(i) 150/250(300)V Cable

MGT/EPR/EPR/TCWB/EVA Offshore Cables

Operating Temperature : 90°C

Operating Voltage : 150/250(300)V

Prysmian Draka BFOV Offshore Cable Applications

Instrumentation Cable nek ts 606

Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32.

Instrumentation Cable Core Identification
  • Pair – Black – Light Blue
  • Triple – Black – Light Blue – Brown
  • Quad – Black – Light Blue – Brown – Grey
BFOV Instrumentation Cable Construction Code Letter BFOV Instrumentation Cable Description
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-360 (EPR)
Pair / Triple / Quad twisting Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.
Lay up, Shielding Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape.
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over inner covering PET tape
Cable armour/screen O Tinned annealed copper wire braid
Tape over armour/scree PET tape
Cable outer sheath V Flame retardant, halogen-free and oil resistant thermoset compound (Therban), SHF2 (IEC 60092-360)
Marking text Eg. “meter” “year” DRAKA NORSK KABEL BFOV(i) 250V 16 PAIR 0,75 mm² FLEX – FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22
Outer sheath colour Grey or blue

*) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes

Cable Standards Applied
Cable Terminations Joints Cleats 6.6kV 11kV 33kV

Cable Joints, Terminations, Glands & Cleats – available for 6.6kV 11kV and 33kV medium voltage (MV) power cables.

  • IEC 60092-376 (2003-05) – Design IEC 60228 class 2 – Conductor
  • IEC 60092-360 – Insulation IEC 60092-360 – Sheath
  • IEC 60332-1-2 – Flame Retardant
  • IEC 60332-3-22 – Flame Retardant
  • IEC 60331-1,-2 EN 50200:2006 Annex E – Fire Resistant
  • IEC 60754-1,2 – Halogen Free
  • IEC 61034-1,2 – Low Smoke
Cable Joints Cable Cleats Cable Glands - Prysmian Cables